Cargando…

Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients

BACKGROUND AND PURPOSE: Dual-mobility cups (DMCs) reduce the risk of dislocation and porous tantalum (TM) shells show favorable osseointegration after acetabular revision surgery, yet the combination of these implants has not been studied. We hypothesized that (1) cementing a DMC into a TM shell dec...

Descripción completa

Detalles Bibliográficos
Autores principales: Brüggemann, Anders, Mallmin, Hans, Hailer, Nils P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5901512/
https://www.ncbi.nlm.nih.gov/pubmed/29400106
http://dx.doi.org/10.1080/17453674.2018.1432927
_version_ 1783314629302157312
author Brüggemann, Anders
Mallmin, Hans
Hailer, Nils P
author_facet Brüggemann, Anders
Mallmin, Hans
Hailer, Nils P
author_sort Brüggemann, Anders
collection PubMed
description BACKGROUND AND PURPOSE: Dual-mobility cups (DMCs) reduce the risk of dislocation and porous tantalum (TM) shells show favorable osseointegration after acetabular revision surgery, yet the combination of these implants has not been studied. We hypothesized that (1) cementing a DMC into a TM shell decreases the risk of dislocation; (2) DMCs cemented into TM shells are not at greater risk of re-revision; (3) liberation of tantalum ions is marginal after use of this combined technique. PATIENTS AND METHODS: We investigated the outcome in 184 hips (184 patients) after acetabular revision surgery with TM shells, fitted either with DMCs (n = 69), or with standard poly­ethylene (PE) liners (n = 115). Chart follow-up was complete for all patients, and the occurrence of dislocations and re-revisions was recorded. 20 were deceased, 50 were unable to attend follow-up, leaving 114 for assessment of hip function after 4.9 (0.5–8.9) years, radiographs were obtained in 99, and tantalum concentrations in 84 patients. RESULTS: 1 patient with a DMC had a dislocation, whereas 14 patients with PE liners experienced at least 1 dislocation. 11 of 15 re-revisions in the PE group were necessitated by dislocations, whereas none of the 2 re-revisions in the DMC group was performed for this reason. Hence, dislocation-free survival after 4 years was 99% (95% CI 96–100) in the DMC group, whereas it was 88% (CI 82–94, p = 0.01) in the PE group. We found no radiographic signs of implant failure in any patient. Mean tantalum concentrations were 0.1 µl/L (CI 0.05–0.2) in the DMC group and 0.1 µg/L (CI 0.05–0.2) in the PE group. INTERPRETATION: Cementing DMCs into TM shells reduces the risk of dislocation after acetabular revision surgery without jeopardizing overall cup survival, and without enhancing tantalum release.
format Online
Article
Text
id pubmed-5901512
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-59015122018-04-23 Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients Brüggemann, Anders Mallmin, Hans Hailer, Nils P Acta Orthop Hip and Knee BACKGROUND AND PURPOSE: Dual-mobility cups (DMCs) reduce the risk of dislocation and porous tantalum (TM) shells show favorable osseointegration after acetabular revision surgery, yet the combination of these implants has not been studied. We hypothesized that (1) cementing a DMC into a TM shell decreases the risk of dislocation; (2) DMCs cemented into TM shells are not at greater risk of re-revision; (3) liberation of tantalum ions is marginal after use of this combined technique. PATIENTS AND METHODS: We investigated the outcome in 184 hips (184 patients) after acetabular revision surgery with TM shells, fitted either with DMCs (n = 69), or with standard poly­ethylene (PE) liners (n = 115). Chart follow-up was complete for all patients, and the occurrence of dislocations and re-revisions was recorded. 20 were deceased, 50 were unable to attend follow-up, leaving 114 for assessment of hip function after 4.9 (0.5–8.9) years, radiographs were obtained in 99, and tantalum concentrations in 84 patients. RESULTS: 1 patient with a DMC had a dislocation, whereas 14 patients with PE liners experienced at least 1 dislocation. 11 of 15 re-revisions in the PE group were necessitated by dislocations, whereas none of the 2 re-revisions in the DMC group was performed for this reason. Hence, dislocation-free survival after 4 years was 99% (95% CI 96–100) in the DMC group, whereas it was 88% (CI 82–94, p = 0.01) in the PE group. We found no radiographic signs of implant failure in any patient. Mean tantalum concentrations were 0.1 µl/L (CI 0.05–0.2) in the DMC group and 0.1 µg/L (CI 0.05–0.2) in the PE group. INTERPRETATION: Cementing DMCs into TM shells reduces the risk of dislocation after acetabular revision surgery without jeopardizing overall cup survival, and without enhancing tantalum release. Taylor & Francis 2018-04 2018-02-05 /pmc/articles/PMC5901512/ /pubmed/29400106 http://dx.doi.org/10.1080/17453674.2018.1432927 Text en © 2018 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0)
spellingShingle Hip and Knee
Brüggemann, Anders
Mallmin, Hans
Hailer, Nils P
Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients
title Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients
title_full Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients
title_fullStr Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients
title_full_unstemmed Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients
title_short Do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: A retrospective cohort study on 184 patients
title_sort do dual-mobility cups cemented into porous tantalum shells reduce the risk of dislocation after revision surgery?: a retrospective cohort study on 184 patients
topic Hip and Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5901512/
https://www.ncbi.nlm.nih.gov/pubmed/29400106
http://dx.doi.org/10.1080/17453674.2018.1432927
work_keys_str_mv AT bruggemannanders dodualmobilitycupscementedintoporoustantalumshellsreducetheriskofdislocationafterrevisionsurgeryaretrospectivecohortstudyon184patients
AT mallminhans dodualmobilitycupscementedintoporoustantalumshellsreducetheriskofdislocationafterrevisionsurgeryaretrospectivecohortstudyon184patients
AT hailernilsp dodualmobilitycupscementedintoporoustantalumshellsreducetheriskofdislocationafterrevisionsurgeryaretrospectivecohortstudyon184patients