Cargando…

Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

Phenytoin (PHT) is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS...

Descripción completa

Detalles Bibliográficos
Autores principales: Hösli, Raphael, König, Stefan, Mühlebach, Stefan F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5901821/
https://www.ncbi.nlm.nih.gov/pubmed/29805839
http://dx.doi.org/10.1155/2018/8274131
_version_ 1783314666956521472
author Hösli, Raphael
König, Stefan
Mühlebach, Stefan F.
author_facet Hösli, Raphael
König, Stefan
Mühlebach, Stefan F.
author_sort Hösli, Raphael
collection PubMed
description Phenytoin (PHT) is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva) and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL) and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis), and resulted in a better LOD (<1 ng/mL)/LOQ (10 ng/mL). The calibration curve of the LC-MS/MS method (10–2000 ng/mL) showed linearity over a larger range with correlation coefficients r(2) > 0.995 for all tested matrices (blood, saliva, and dialysate). For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.
format Online
Article
Text
id pubmed-5901821
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-59018212018-05-27 Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva Hösli, Raphael König, Stefan Mühlebach, Stefan F. J Anal Methods Chem Research Article Phenytoin (PHT) is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva) and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL) and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis), and resulted in a better LOD (<1 ng/mL)/LOQ (10 ng/mL). The calibration curve of the LC-MS/MS method (10–2000 ng/mL) showed linearity over a larger range with correlation coefficients r(2) > 0.995 for all tested matrices (blood, saliva, and dialysate). For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method. Hindawi 2018-04-01 /pmc/articles/PMC5901821/ /pubmed/29805839 http://dx.doi.org/10.1155/2018/8274131 Text en Copyright © 2018 Raphael Hösli et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hösli, Raphael
König, Stefan
Mühlebach, Stefan F.
Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
title Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
title_full Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
title_fullStr Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
title_full_unstemmed Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
title_short Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva
title_sort development and validation of an lc-ms/ms method and comparison with a gc-ms method to measure phenytoin in human brain dialysate, blood, and saliva
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5901821/
https://www.ncbi.nlm.nih.gov/pubmed/29805839
http://dx.doi.org/10.1155/2018/8274131
work_keys_str_mv AT hosliraphael developmentandvalidationofanlcmsmsmethodandcomparisonwithagcmsmethodtomeasurephenytoininhumanbraindialysatebloodandsaliva
AT konigstefan developmentandvalidationofanlcmsmsmethodandcomparisonwithagcmsmethodtomeasurephenytoininhumanbraindialysatebloodandsaliva
AT muhlebachstefanf developmentandvalidationofanlcmsmsmethodandcomparisonwithagcmsmethodtomeasurephenytoininhumanbraindialysatebloodandsaliva