Cargando…
Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation
STATEMENT OF PROBLEM: In clinical situations, short implant abutments create lack of retention with overlying cemented prosthesis. AIMS: The aim of this study is to evaluate the impact of different surface treatments on the retention of implant-supported cement-retained bridge with short implant abu...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5903179/ https://www.ncbi.nlm.nih.gov/pubmed/29692569 http://dx.doi.org/10.4103/jips.jips_251_17 |
_version_ | 1783314903735468032 |
---|---|
author | Shrivastav, Monica |
author_facet | Shrivastav, Monica |
author_sort | Shrivastav, Monica |
collection | PubMed |
description | STATEMENT OF PROBLEM: In clinical situations, short implant abutments create lack of retention with overlying cemented prosthesis. AIMS: The aim of this study is to evaluate the impact of different surface treatments on the retention of implant-supported cement-retained bridge with short implant abutments. MATERIALS AND METHODS: Six straight Adin implant abutments of similar sizes (3 mm diameter × 3 mm height) were selected. All were divided into three groups (n = 2): with circumferential grooves and sandblasting (G + SB), with a circumferential groove and bur modification (G + B) and third one taken as control. The framework simulating three-unit bridge was casted in each group. A total of 30 such frameworks (10 for each group) were fabricated. Each casting was cemented with a zinc phosphate cement (Dentsply). The cemented frameworks were then being stored in 100% humidity at 37°C for 24 h. Retention tests were conducted with a universal testing machine (5 mm/min), and retentive forces were recorded. Data were subjected to one-way analysis of variance, Tukey's honestly significant difference test, (α = 0.05). RESULTS: For the first group, retentive value increased by 619.30 N, the second group increased the retention by approximately 749.80 N (P < 0.001). The null hypothesis was rejected, the abutments with G + B showed significantly higher retention, than the G + SB and control group (F = 15.95, df = 29, P < 0.001). CONCLUSION: The addition of G + B to implant abutments significantly increased the retention of cement-retained frameworks. For long-term prognosis of the prosthesis; G + B modification can be a better option as compared to G + SB. |
format | Online Article Text |
id | pubmed-5903179 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-59031792019-04-01 Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation Shrivastav, Monica J Indian Prosthodont Soc Original Article STATEMENT OF PROBLEM: In clinical situations, short implant abutments create lack of retention with overlying cemented prosthesis. AIMS: The aim of this study is to evaluate the impact of different surface treatments on the retention of implant-supported cement-retained bridge with short implant abutments. MATERIALS AND METHODS: Six straight Adin implant abutments of similar sizes (3 mm diameter × 3 mm height) were selected. All were divided into three groups (n = 2): with circumferential grooves and sandblasting (G + SB), with a circumferential groove and bur modification (G + B) and third one taken as control. The framework simulating three-unit bridge was casted in each group. A total of 30 such frameworks (10 for each group) were fabricated. Each casting was cemented with a zinc phosphate cement (Dentsply). The cemented frameworks were then being stored in 100% humidity at 37°C for 24 h. Retention tests were conducted with a universal testing machine (5 mm/min), and retentive forces were recorded. Data were subjected to one-way analysis of variance, Tukey's honestly significant difference test, (α = 0.05). RESULTS: For the first group, retentive value increased by 619.30 N, the second group increased the retention by approximately 749.80 N (P < 0.001). The null hypothesis was rejected, the abutments with G + B showed significantly higher retention, than the G + SB and control group (F = 15.95, df = 29, P < 0.001). CONCLUSION: The addition of G + B to implant abutments significantly increased the retention of cement-retained frameworks. For long-term prognosis of the prosthesis; G + B modification can be a better option as compared to G + SB. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5903179/ /pubmed/29692569 http://dx.doi.org/10.4103/jips.jips_251_17 Text en Copyright: © 2018 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Shrivastav, Monica Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation |
title | Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation |
title_full | Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation |
title_fullStr | Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation |
title_full_unstemmed | Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation |
title_short | Effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: An in vitro comparative evaluation |
title_sort | effect of surface treatments on the retention of implant-supported cement-retained bridge with short abutments: an in vitro comparative evaluation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5903179/ https://www.ncbi.nlm.nih.gov/pubmed/29692569 http://dx.doi.org/10.4103/jips.jips_251_17 |
work_keys_str_mv | AT shrivastavmonica effectofsurfacetreatmentsontheretentionofimplantsupportedcementretainedbridgewithshortabutmentsaninvitrocomparativeevaluation |