Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study

PURPOSE: The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. MATERIALS AND METHODS: 3D models of implants (conical connection wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanneganti, Krishna Chaitanya, Vinnakota, Dileep Nag, Pottem, Srinivas Rao, Pulagam, Mahesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5903180/
https://www.ncbi.nlm.nih.gov/pubmed/29692570
http://dx.doi.org/10.4103/jips.jips_219_17
_version_ 1783314903966154752
author Kanneganti, Krishna Chaitanya
Vinnakota, Dileep Nag
Pottem, Srinivas Rao
Pulagam, Mahesh
author_facet Kanneganti, Krishna Chaitanya
Vinnakota, Dileep Nag
Pottem, Srinivas Rao
Pulagam, Mahesh
author_sort Kanneganti, Krishna Chaitanya
collection PubMed
description PURPOSE: The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. MATERIALS AND METHODS: 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. RESULTS: In straight abutment models, conical connection showed more damage (14.3%–72.3%) when compared to trilobe (10.1%–65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%–76.9%) demonstrated more damage compared to conical (13.5%–70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. CONCLUSIONS: The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.
format Online
Article
Text
id pubmed-5903180
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-59031802019-04-01 Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study Kanneganti, Krishna Chaitanya Vinnakota, Dileep Nag Pottem, Srinivas Rao Pulagam, Mahesh J Indian Prosthodont Soc Original Article PURPOSE: The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. MATERIALS AND METHODS: 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. RESULTS: In straight abutment models, conical connection showed more damage (14.3%–72.3%) when compared to trilobe (10.1%–65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%–76.9%) demonstrated more damage compared to conical (13.5%–70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. CONCLUSIONS: The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5903180/ /pubmed/29692570 http://dx.doi.org/10.4103/jips.jips_219_17 Text en Copyright: © 2018 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kanneganti, Krishna Chaitanya
Vinnakota, Dileep Nag
Pottem, Srinivas Rao
Pulagam, Mahesh
Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
title Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
title_full Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
title_fullStr Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
title_full_unstemmed Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
title_short Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study
title_sort comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5903180/
https://www.ncbi.nlm.nih.gov/pubmed/29692570
http://dx.doi.org/10.4103/jips.jips_219_17
work_keys_str_mv AT kannegantikrishnachaitanya comparativeeffectofimplantabutmentconnectionsabutmentangulationsandscrewlengthsonpreloadedabutmentscrewusingthreedimensionalfiniteelementanalysisaninvitrostudy
AT vinnakotadileepnag comparativeeffectofimplantabutmentconnectionsabutmentangulationsandscrewlengthsonpreloadedabutmentscrewusingthreedimensionalfiniteelementanalysisaninvitrostudy
AT pottemsrinivasrao comparativeeffectofimplantabutmentconnectionsabutmentangulationsandscrewlengthsonpreloadedabutmentscrewusingthreedimensionalfiniteelementanalysisaninvitrostudy
AT pulagammahesh comparativeeffectofimplantabutmentconnectionsabutmentangulationsandscrewlengthsonpreloadedabutmentscrewusingthreedimensionalfiniteelementanalysisaninvitrostudy