Cargando…
Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes
BACKGROUND: Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5905124/ https://www.ncbi.nlm.nih.gov/pubmed/29692684 http://dx.doi.org/10.1186/s12912-018-0283-1 |
_version_ | 1783315211850088448 |
---|---|
author | Seifi, Sohila Khatony, Alireza Moradi, Gholamreza Abdi, Alireza Najafi, Farid |
author_facet | Seifi, Sohila Khatony, Alireza Moradi, Gholamreza Abdi, Alireza Najafi, Farid |
author_sort | Seifi, Sohila |
collection | PubMed |
description | BACKGROUND: Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse oximetry probes and lack of data related to patients undergoing heart surgery, the present study was conducted to determine accuracy of pulse oximetry probes of finger, toe, forehead and earlobe in detection of oxygen saturation in patients admitted to intensive care units for coronary artery bypass surgery. METHODS: In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. The SpO2 value was measured using finger, toe, forehead and earlobe probes and then compared with the standard value of arterial oxygen saturation (SaO2). Data were entered into STATA-11 software and analyzed using descriptive, inferential and Bland-Altman statistical analyses. RESULTS: Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively. The highest and lowest agreement of SpO2 and SaO2 were related to forehead and earlobe probes. CONCLUSION: The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas (ABG) analysis had higher accuracy. Thus, it is suggested to use earlobe probes in patients admitted to the intensive care unit for coronary artery bypass surgery. TRIAL REGISTRATION: Registration of this trial protocol has been approved in Iranian Registry of Clinical Trials at 2018–03-19 with reference IRCT20100913004736N22. “Retrospectively registered.” |
format | Online Article Text |
id | pubmed-5905124 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-59051242018-04-24 Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes Seifi, Sohila Khatony, Alireza Moradi, Gholamreza Abdi, Alireza Najafi, Farid BMC Nurs Research Article BACKGROUND: Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse oximetry probes and lack of data related to patients undergoing heart surgery, the present study was conducted to determine accuracy of pulse oximetry probes of finger, toe, forehead and earlobe in detection of oxygen saturation in patients admitted to intensive care units for coronary artery bypass surgery. METHODS: In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. The SpO2 value was measured using finger, toe, forehead and earlobe probes and then compared with the standard value of arterial oxygen saturation (SaO2). Data were entered into STATA-11 software and analyzed using descriptive, inferential and Bland-Altman statistical analyses. RESULTS: Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively. The highest and lowest agreement of SpO2 and SaO2 were related to forehead and earlobe probes. CONCLUSION: The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas (ABG) analysis had higher accuracy. Thus, it is suggested to use earlobe probes in patients admitted to the intensive care unit for coronary artery bypass surgery. TRIAL REGISTRATION: Registration of this trial protocol has been approved in Iranian Registry of Clinical Trials at 2018–03-19 with reference IRCT20100913004736N22. “Retrospectively registered.” BioMed Central 2018-04-17 /pmc/articles/PMC5905124/ /pubmed/29692684 http://dx.doi.org/10.1186/s12912-018-0283-1 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Seifi, Sohila Khatony, Alireza Moradi, Gholamreza Abdi, Alireza Najafi, Farid Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
title | Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
title_full | Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
title_fullStr | Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
title_full_unstemmed | Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
title_short | Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
title_sort | accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5905124/ https://www.ncbi.nlm.nih.gov/pubmed/29692684 http://dx.doi.org/10.1186/s12912-018-0283-1 |
work_keys_str_mv | AT seifisohila accuracyofpulseoximetryindetectionofoxygensaturationinpatientsadmittedtotheintensivecareunitofheartsurgerycomparisonoffingertoeforeheadandearlobeprobes AT khatonyalireza accuracyofpulseoximetryindetectionofoxygensaturationinpatientsadmittedtotheintensivecareunitofheartsurgerycomparisonoffingertoeforeheadandearlobeprobes AT moradigholamreza accuracyofpulseoximetryindetectionofoxygensaturationinpatientsadmittedtotheintensivecareunitofheartsurgerycomparisonoffingertoeforeheadandearlobeprobes AT abdialireza accuracyofpulseoximetryindetectionofoxygensaturationinpatientsadmittedtotheintensivecareunitofheartsurgerycomparisonoffingertoeforeheadandearlobeprobes AT najafifarid accuracyofpulseoximetryindetectionofoxygensaturationinpatientsadmittedtotheintensivecareunitofheartsurgerycomparisonoffingertoeforeheadandearlobeprobes |