Cargando…

Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model

Intra-aortic balloon pump (IABP) is normally contraindicated in significant aortic regurgitation (AR). It causes and aggravates pre-existing AR while performing well in the event of mitral regurgitation (MR). Indirect parameters, such as the mean systolic pressure, product of heart rate and peak sys...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Chang-Hyun, Song, Kwang-Soup, Trayanova, Natalia A., Lim, Ki Moo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5906536/
https://www.ncbi.nlm.nih.gov/pubmed/29058110
http://dx.doi.org/10.1007/s11517-017-1731-x
_version_ 1783315390721425408
author Kim, Chang-Hyun
Song, Kwang-Soup
Trayanova, Natalia A.
Lim, Ki Moo
author_facet Kim, Chang-Hyun
Song, Kwang-Soup
Trayanova, Natalia A.
Lim, Ki Moo
author_sort Kim, Chang-Hyun
collection PubMed
description Intra-aortic balloon pump (IABP) is normally contraindicated in significant aortic regurgitation (AR). It causes and aggravates pre-existing AR while performing well in the event of mitral regurgitation (MR). Indirect parameters, such as the mean systolic pressure, product of heart rate and peak systolic pressure, and pressure–volume are used to quantify the effect of IABP on ventricular workload. However, to date, no studies have directly quantified the reduction in workload with IABP. The goal of this study is to examine the effect of IABP therapy on ventricular mechanics under valvular insufficiency by using a computational model of the heart. For this purpose, the 3D electromechanical model of the failing ventricles used in previous studies was coupled with a lumped parameter model of valvular regurgitation and the IABP-treated vascular system. The IABP therapy was disturbed in terms of reducing the myocardial tension generation and contractile ATP consumption by valvular regurgitation, particularly in the AR condition. The IABP worsened the problem of ventricular expansion induced as a result of the regurgitated blood volume during the diastole under the AR condition. The IABP reduced the LV stroke work in the AR, MR, and no regurgitation conditions. Therefore, the IABP helped the ventricle to pump blood and reduced the ventricular workload. In conclusion, the IABP partially performed its role in the MR condition. However, it was disturbed by the AR and worsened the cardiovascular responses that followed the AR. Therefore, this study computationally proved the reason for the clinical contraindication of IABP in AR patients.
format Online
Article
Text
id pubmed-5906536
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-59065362018-04-20 Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model Kim, Chang-Hyun Song, Kwang-Soup Trayanova, Natalia A. Lim, Ki Moo Med Biol Eng Comput Original Article Intra-aortic balloon pump (IABP) is normally contraindicated in significant aortic regurgitation (AR). It causes and aggravates pre-existing AR while performing well in the event of mitral regurgitation (MR). Indirect parameters, such as the mean systolic pressure, product of heart rate and peak systolic pressure, and pressure–volume are used to quantify the effect of IABP on ventricular workload. However, to date, no studies have directly quantified the reduction in workload with IABP. The goal of this study is to examine the effect of IABP therapy on ventricular mechanics under valvular insufficiency by using a computational model of the heart. For this purpose, the 3D electromechanical model of the failing ventricles used in previous studies was coupled with a lumped parameter model of valvular regurgitation and the IABP-treated vascular system. The IABP therapy was disturbed in terms of reducing the myocardial tension generation and contractile ATP consumption by valvular regurgitation, particularly in the AR condition. The IABP worsened the problem of ventricular expansion induced as a result of the regurgitated blood volume during the diastole under the AR condition. The IABP reduced the LV stroke work in the AR, MR, and no regurgitation conditions. Therefore, the IABP helped the ventricle to pump blood and reduced the ventricular workload. In conclusion, the IABP partially performed its role in the MR condition. However, it was disturbed by the AR and worsened the cardiovascular responses that followed the AR. Therefore, this study computationally proved the reason for the clinical contraindication of IABP in AR patients. Springer Berlin Heidelberg 2017-10-23 2018 /pmc/articles/PMC5906536/ /pubmed/29058110 http://dx.doi.org/10.1007/s11517-017-1731-x Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Kim, Chang-Hyun
Song, Kwang-Soup
Trayanova, Natalia A.
Lim, Ki Moo
Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model
title Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model
title_full Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model
title_fullStr Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model
title_full_unstemmed Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model
title_short Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model
title_sort computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3d cardiac electromechanical model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5906536/
https://www.ncbi.nlm.nih.gov/pubmed/29058110
http://dx.doi.org/10.1007/s11517-017-1731-x
work_keys_str_mv AT kimchanghyun computationalpredictionoftheeffectsoftheintraaorticballoonpumponheartfailurewithvalvularregurgitationusinga3dcardiacelectromechanicalmodel
AT songkwangsoup computationalpredictionoftheeffectsoftheintraaorticballoonpumponheartfailurewithvalvularregurgitationusinga3dcardiacelectromechanicalmodel
AT trayanovanataliaa computationalpredictionoftheeffectsoftheintraaorticballoonpumponheartfailurewithvalvularregurgitationusinga3dcardiacelectromechanicalmodel
AT limkimoo computationalpredictionoftheeffectsoftheintraaorticballoonpumponheartfailurewithvalvularregurgitationusinga3dcardiacelectromechanicalmodel