Cargando…
Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study
BACKGROUND: The smartphone-based whole slide imaging (WSI) system represents a low-cost and effective alternative to automatic scanners for telepathology. In a previous study, the development of one such solution, named scalable whole slide imaging (sWSI), was presented and analyzed. A clinical eval...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5906711/ https://www.ncbi.nlm.nih.gov/pubmed/29618454 http://dx.doi.org/10.2196/mhealth.9518 |
_version_ | 1783315431234207744 |
---|---|
author | Huang, Yu-Ning Peng, Xing-Chun Ma, Shuoxin Yu, Hong Jin, Yu-Biao Zheng, Jun Fu, Guo-Hui |
author_facet | Huang, Yu-Ning Peng, Xing-Chun Ma, Shuoxin Yu, Hong Jin, Yu-Biao Zheng, Jun Fu, Guo-Hui |
author_sort | Huang, Yu-Ning |
collection | PubMed |
description | BACKGROUND: The smartphone-based whole slide imaging (WSI) system represents a low-cost and effective alternative to automatic scanners for telepathology. In a previous study, the development of one such solution, named scalable whole slide imaging (sWSI), was presented and analyzed. A clinical evaluation of its iOS version with 100 frozen section samples verified the diagnosis-readiness of the produced virtual slides. OBJECTIVE: The first aim of this study was to delve into the quantifying issues encountered in the development of an Android version. It should also provide insights into future high-resolution real-time feedback medical imaging apps on Android and invoke the awareness of smartphone manufacturers for collaboration. The second aim of this study was to further verify the clinical value of sWSI with cytology samples. This type is different from the frozen section samples in that they require finer detail on the cellular level. METHODS: During sWSI development on Android, it was discovered that many models do not support uncompressed camera pixel data with sufficient resolution and full field of view. The proportion of models supporting the optimal format was estimated in a test on 200 mainstream Android models. Other factors, including slower processing speed and camera preview freezing, also led to inferior performance of sWSI on Android compared with the iOS version. The processing speed was mostly determined by the central processing unit frequency in theory, and the relationship was investigated in the 200-model simulation experiment with physical devices. The camera preview freezing was caused by the lag between triggering photo capture and resuming preview. In the clinical evaluation, 100 ThinPrep cytology test samples covering 6 diseases were scanned with sWSI and compared against the ground truth of optical microscopy. RESULTS: Among the tested Android models, only 3.0% (6/200) provided an optimal data format, meeting all criteria of quality and efficiency. The image-processing speed demonstrated a positive relationship with the central processing unit frequency but to a smaller degree than expected and was highly model-dependent. The virtual slides produced by sWSI on Android and iOS of ThinPrep cytology test samples achieved similar high quality. Using optical microscopy as the ground truth, pathologists made a correct diagnosis on 87.5% (175/200) of the cases with sWSI virtual slides. Depending on the sWSI version and the pathologist in charge, the kappa value varied between .70 and .82. All participating pathologists considered the quality of the sWSI virtual slides in the experiment to be adequate for routine usage. CONCLUSIONS: Limited by hardware and operating system support, the performance of sWSI on mainstream Android smartphones did not fully match the iOS version. However, in practice, this difference was not significant, and both were adequate for digitizing most of the sample types for telepathology consultation. |
format | Online Article Text |
id | pubmed-5906711 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-59067112018-04-24 Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study Huang, Yu-Ning Peng, Xing-Chun Ma, Shuoxin Yu, Hong Jin, Yu-Biao Zheng, Jun Fu, Guo-Hui JMIR Mhealth Uhealth Original Paper BACKGROUND: The smartphone-based whole slide imaging (WSI) system represents a low-cost and effective alternative to automatic scanners for telepathology. In a previous study, the development of one such solution, named scalable whole slide imaging (sWSI), was presented and analyzed. A clinical evaluation of its iOS version with 100 frozen section samples verified the diagnosis-readiness of the produced virtual slides. OBJECTIVE: The first aim of this study was to delve into the quantifying issues encountered in the development of an Android version. It should also provide insights into future high-resolution real-time feedback medical imaging apps on Android and invoke the awareness of smartphone manufacturers for collaboration. The second aim of this study was to further verify the clinical value of sWSI with cytology samples. This type is different from the frozen section samples in that they require finer detail on the cellular level. METHODS: During sWSI development on Android, it was discovered that many models do not support uncompressed camera pixel data with sufficient resolution and full field of view. The proportion of models supporting the optimal format was estimated in a test on 200 mainstream Android models. Other factors, including slower processing speed and camera preview freezing, also led to inferior performance of sWSI on Android compared with the iOS version. The processing speed was mostly determined by the central processing unit frequency in theory, and the relationship was investigated in the 200-model simulation experiment with physical devices. The camera preview freezing was caused by the lag between triggering photo capture and resuming preview. In the clinical evaluation, 100 ThinPrep cytology test samples covering 6 diseases were scanned with sWSI and compared against the ground truth of optical microscopy. RESULTS: Among the tested Android models, only 3.0% (6/200) provided an optimal data format, meeting all criteria of quality and efficiency. The image-processing speed demonstrated a positive relationship with the central processing unit frequency but to a smaller degree than expected and was highly model-dependent. The virtual slides produced by sWSI on Android and iOS of ThinPrep cytology test samples achieved similar high quality. Using optical microscopy as the ground truth, pathologists made a correct diagnosis on 87.5% (175/200) of the cases with sWSI virtual slides. Depending on the sWSI version and the pathologist in charge, the kappa value varied between .70 and .82. All participating pathologists considered the quality of the sWSI virtual slides in the experiment to be adequate for routine usage. CONCLUSIONS: Limited by hardware and operating system support, the performance of sWSI on mainstream Android smartphones did not fully match the iOS version. However, in practice, this difference was not significant, and both were adequate for digitizing most of the sample types for telepathology consultation. JMIR Publications 2018-04-04 /pmc/articles/PMC5906711/ /pubmed/29618454 http://dx.doi.org/10.2196/mhealth.9518 Text en ©Yu-Ning Huang, Xing-Chun Peng, Shuoxin Ma, Hong Yu, Yu-Biao Jin, Jun Zheng, Guo-Hui Fu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 04.04.2018. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Huang, Yu-Ning Peng, Xing-Chun Ma, Shuoxin Yu, Hong Jin, Yu-Biao Zheng, Jun Fu, Guo-Hui Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study |
title | Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study |
title_full | Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study |
title_fullStr | Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study |
title_full_unstemmed | Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study |
title_short | Development of Whole Slide Imaging on Smartphones and Evaluation With ThinPrep Cytology Test Samples: Follow-Up Study |
title_sort | development of whole slide imaging on smartphones and evaluation with thinprep cytology test samples: follow-up study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5906711/ https://www.ncbi.nlm.nih.gov/pubmed/29618454 http://dx.doi.org/10.2196/mhealth.9518 |
work_keys_str_mv | AT huangyuning developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy AT pengxingchun developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy AT mashuoxin developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy AT yuhong developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy AT jinyubiao developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy AT zhengjun developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy AT fuguohui developmentofwholeslideimagingonsmartphonesandevaluationwiththinprepcytologytestsamplesfollowupstudy |