Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection
The precise sizing of the stent graft in thoracic endovascular aortic repair (TEVAR) affects aortic remodeling and hence, further outcome. Covering the proximal entry tear is essential for successful treatment of Type B aortic dissection. Intravascular ultrasound (IVUS) enables real-time aortic diam...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5908162/ https://www.ncbi.nlm.nih.gov/pubmed/29672613 http://dx.doi.org/10.1371/journal.pone.0196180 |
_version_ | 1783315671759716352 |
---|---|
author | Lortz, Julia Tsagakis, Konstantinos Rammos, Christos Horacek, Michael Schlosser, Thomas Jakob, Heinz Rassaf, Tienush Jánosi, Rolf Alexander |
author_facet | Lortz, Julia Tsagakis, Konstantinos Rammos, Christos Horacek, Michael Schlosser, Thomas Jakob, Heinz Rassaf, Tienush Jánosi, Rolf Alexander |
author_sort | Lortz, Julia |
collection | PubMed |
description | The precise sizing of the stent graft in thoracic endovascular aortic repair (TEVAR) affects aortic remodeling and hence, further outcome. Covering the proximal entry tear is essential for successful treatment of Type B aortic dissection. Intravascular ultrasound (IVUS) enables real-time aortic diameter assessment, and is especially useful when computed tomography (CT) image quality is poor. IVUS, however, is not routinely utilized due to cost inefficiency. We investigated the impact of IVUS-assisted stent graft sizing on aortic remodeling in TEVAR. In this single-center retrospective study we evaluated patients with Type B aortic dissection undergoing both CT and IVUS before TEVAR. We assessed the aortic diameter at the level of the left subclavian artery via both methods before stent implantation and analyzed due to which method the implanted stent graft was chosen, retrospectively. To determine the degrees of aortic remodeling involved, we evaluated true lumen and false lumen diameters, and total aortic remodeling in CT. We analyzed 45 patients with Type B aortic dissection undergoing TEVAR. The mean ages were 66.9±10.0 years fo0072 IVUS (n = 20) and 62.3±14.2 years for CT-assisted TEVAR (n = 25; p = 0.226). The follow-up time for both groups did not differ between the two groups (IVUS: 22.9±23.1 months, CT: 25.6±23.0 months; p = 0.700). While both methods were associated with advantages regarding aortic remodeling, IVUS-assisted sizing yielded a greater increase in true lumen (30.4±6.2 vs. 25.6±5.3; p = 0.008) and reductions in false lumen (14.4±8.5 vs. 23.9±9.3; p = 0.001) and total aortic diameter (35.5±6.0 vs. 39.9±8.1; p = 0.045). IVUS-guided stent graft sizing in Type B aortic dissection shows beneficial effects on aortic remodeling and might be of additional advantage in aortic diseases, especially when CT image quality is poor. |
format | Online Article Text |
id | pubmed-5908162 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-59081622018-05-06 Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection Lortz, Julia Tsagakis, Konstantinos Rammos, Christos Horacek, Michael Schlosser, Thomas Jakob, Heinz Rassaf, Tienush Jánosi, Rolf Alexander PLoS One Research Article The precise sizing of the stent graft in thoracic endovascular aortic repair (TEVAR) affects aortic remodeling and hence, further outcome. Covering the proximal entry tear is essential for successful treatment of Type B aortic dissection. Intravascular ultrasound (IVUS) enables real-time aortic diameter assessment, and is especially useful when computed tomography (CT) image quality is poor. IVUS, however, is not routinely utilized due to cost inefficiency. We investigated the impact of IVUS-assisted stent graft sizing on aortic remodeling in TEVAR. In this single-center retrospective study we evaluated patients with Type B aortic dissection undergoing both CT and IVUS before TEVAR. We assessed the aortic diameter at the level of the left subclavian artery via both methods before stent implantation and analyzed due to which method the implanted stent graft was chosen, retrospectively. To determine the degrees of aortic remodeling involved, we evaluated true lumen and false lumen diameters, and total aortic remodeling in CT. We analyzed 45 patients with Type B aortic dissection undergoing TEVAR. The mean ages were 66.9±10.0 years fo0072 IVUS (n = 20) and 62.3±14.2 years for CT-assisted TEVAR (n = 25; p = 0.226). The follow-up time for both groups did not differ between the two groups (IVUS: 22.9±23.1 months, CT: 25.6±23.0 months; p = 0.700). While both methods were associated with advantages regarding aortic remodeling, IVUS-assisted sizing yielded a greater increase in true lumen (30.4±6.2 vs. 25.6±5.3; p = 0.008) and reductions in false lumen (14.4±8.5 vs. 23.9±9.3; p = 0.001) and total aortic diameter (35.5±6.0 vs. 39.9±8.1; p = 0.045). IVUS-guided stent graft sizing in Type B aortic dissection shows beneficial effects on aortic remodeling and might be of additional advantage in aortic diseases, especially when CT image quality is poor. Public Library of Science 2018-04-19 /pmc/articles/PMC5908162/ /pubmed/29672613 http://dx.doi.org/10.1371/journal.pone.0196180 Text en © 2018 Lortz et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Lortz, Julia Tsagakis, Konstantinos Rammos, Christos Horacek, Michael Schlosser, Thomas Jakob, Heinz Rassaf, Tienush Jánosi, Rolf Alexander Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection |
title | Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection |
title_full | Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection |
title_fullStr | Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection |
title_full_unstemmed | Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection |
title_short | Intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in Type B aortic dissection |
title_sort | intravascular ultrasound assisted sizing in thoracic endovascular aortic repair improves aortic remodeling in type b aortic dissection |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5908162/ https://www.ncbi.nlm.nih.gov/pubmed/29672613 http://dx.doi.org/10.1371/journal.pone.0196180 |
work_keys_str_mv | AT lortzjulia intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT tsagakiskonstantinos intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT rammoschristos intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT horacekmichael intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT schlosserthomas intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT jakobheinz intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT rassaftienush intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection AT janosirolfalexander intravascularultrasoundassistedsizinginthoracicendovascularaorticrepairimprovesaorticremodelingintypebaorticdissection |