The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor

[Purpose] The purpose of this study is to find the best body spots on the chest and abdomen wall to obtain the correlated indicators to the vital capacity. [Subjects and Methods] Thirty healthy male staff of the center served as the participants were advised to conduct a breathing movement using spi...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Haijuan, Guo, Shaopeng, Liu, Huilin, Zhang, Hao, Chen, Sujie, Kuramoto-Ahuja, Tsugumi, Sato, Tamae, Kaneko, Junichiro, Onoda, Ko, Maruyama, Hitoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5909008/
https://www.ncbi.nlm.nih.gov/pubmed/29706712
http://dx.doi.org/10.1589/jpts.30.586
_version_ 1783315813681332224
author Liu, Haijuan
Guo, Shaopeng
Liu, Huilin
Zhang, Hao
Chen, Sujie
Kuramoto-Ahuja, Tsugumi
Sato, Tamae
Kaneko, Junichiro
Onoda, Ko
Maruyama, Hitoshi
author_facet Liu, Haijuan
Guo, Shaopeng
Liu, Huilin
Zhang, Hao
Chen, Sujie
Kuramoto-Ahuja, Tsugumi
Sato, Tamae
Kaneko, Junichiro
Onoda, Ko
Maruyama, Hitoshi
author_sort Liu, Haijuan
collection PubMed
description [Purpose] The purpose of this study is to find the best body spots on the chest and abdomen wall to obtain the correlated indicators to the vital capacity. [Subjects and Methods] Thirty healthy male staff of the center served as the participants were advised to conduct a breathing movement using spirometer and a wearable strain sensor (WSS) respectively, which was the measured at four spots on chest and abdomen wall from maximal end of inspiration to maximal end of expiration. The Pearson’s correlation analysis was conducted to find the correlation of the data obtained respectively by the WSS and spirometer. [Results] The correlation of the mobility data at the four body spots to the vital capacity data were calculated for each level by means of Pearson’s correlation coefficient, which showed that the values at each body spot were positive significant correlations and the highest value was at the 10th rib. [Conclusion] There was a correlation between the mobility data of the chest and abdomen obtained by the WSS and the vital capacity data obtained by the spirometer, for which, the 10th rib is the best body spot to detect the positive significant correlation.
format Online
Article
Text
id pubmed-5909008
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-59090082018-04-27 The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor Liu, Haijuan Guo, Shaopeng Liu, Huilin Zhang, Hao Chen, Sujie Kuramoto-Ahuja, Tsugumi Sato, Tamae Kaneko, Junichiro Onoda, Ko Maruyama, Hitoshi J Phys Ther Sci Original Article [Purpose] The purpose of this study is to find the best body spots on the chest and abdomen wall to obtain the correlated indicators to the vital capacity. [Subjects and Methods] Thirty healthy male staff of the center served as the participants were advised to conduct a breathing movement using spirometer and a wearable strain sensor (WSS) respectively, which was the measured at four spots on chest and abdomen wall from maximal end of inspiration to maximal end of expiration. The Pearson’s correlation analysis was conducted to find the correlation of the data obtained respectively by the WSS and spirometer. [Results] The correlation of the mobility data at the four body spots to the vital capacity data were calculated for each level by means of Pearson’s correlation coefficient, which showed that the values at each body spot were positive significant correlations and the highest value was at the 10th rib. [Conclusion] There was a correlation between the mobility data of the chest and abdomen obtained by the WSS and the vital capacity data obtained by the spirometer, for which, the 10th rib is the best body spot to detect the positive significant correlation. The Society of Physical Therapy Science 2018-04-20 2018-04 /pmc/articles/PMC5909008/ /pubmed/29706712 http://dx.doi.org/10.1589/jpts.30.586 Text en 2018©by the Society of Physical Therapy Science. Published by IPEC Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Article
Liu, Haijuan
Guo, Shaopeng
Liu, Huilin
Zhang, Hao
Chen, Sujie
Kuramoto-Ahuja, Tsugumi
Sato, Tamae
Kaneko, Junichiro
Onoda, Ko
Maruyama, Hitoshi
The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
title The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
title_full The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
title_fullStr The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
title_full_unstemmed The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
title_short The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
title_sort best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5909008/
https://www.ncbi.nlm.nih.gov/pubmed/29706712
http://dx.doi.org/10.1589/jpts.30.586
work_keys_str_mv AT liuhaijuan thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT guoshaopeng thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT liuhuilin thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT zhanghao thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT chensujie thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT kuramotoahujatsugumi thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT satotamae thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT kanekojunichiro thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT onodako thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT maruyamahitoshi thebestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT liuhaijuan bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT guoshaopeng bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT liuhuilin bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT zhanghao bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT chensujie bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT kuramotoahujatsugumi bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT satotamae bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT kanekojunichiro bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT onodako bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor
AT maruyamahitoshi bestbodyspottodetectthevitalcapacityfromtherespiratorymovementdataobtainedbythewearablestrainsensor