Cargando…
Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications
OBJECTIVES: We sought to investigate angiographic indications for the use of the STENTYS technique and evaluated the long-term safety and clinical efficacy of the stent. BACKGROUND: Coronary lesions involving complex anatomy, including aneurysmatic, ectatic, or tapered vessel segments often carry a ...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5910317/ https://www.ncbi.nlm.nih.gov/pubmed/29654515 http://dx.doi.org/10.1007/s12471-018-1111-7 |
_version_ | 1783316023558012928 |
---|---|
author | Lu, H. Bekker, R. J. Grundeken, M. J. Woudstra, P. Wykrzykowska, J. J. Tijssen, J. G. P. de Winter, R. J. Koch, K. T. |
author_facet | Lu, H. Bekker, R. J. Grundeken, M. J. Woudstra, P. Wykrzykowska, J. J. Tijssen, J. G. P. de Winter, R. J. Koch, K. T. |
author_sort | Lu, H. |
collection | PubMed |
description | OBJECTIVES: We sought to investigate angiographic indications for the use of the STENTYS technique and evaluated the long-term safety and clinical efficacy of the stent. BACKGROUND: Coronary lesions involving complex anatomy, including aneurysmatic, ectatic, or tapered vessel segments often carry a substantial risk of stent malapposition. The self-apposing stent technique may reduce the risk of stent malapposition and therefore improve clinical outcomes. METHODS: A total of 120 consecutive patients treated with the STENTYS stent were included (drug-eluting stent (DES) n = 101, bare-metal stent (BMS) n = 19). All lesions were scored for angiographic indications for the STENTYS stent, including aneurysms, ectasias, tapering, absolute diameters, bifurcation lesions, and saphenous vein grafts. Off-line quantitative coronary angiography analyses were performed pre-procedure and post-procedure. Five years follow-up was obtained including cardiac death, target vessel myocardial infarction (TV-MI), target vessel revascularisation, stent thrombosis, and the composite endpoint target vessel failure (cardiac death, TV-MI and target vessel revascularisation). RESULTS: Angiographic indications for STENTYS use were aneurysm (30%), ectasia (19%), tapering (27%), bifurcation lesions (8%), and saphenous vein graft lesions (16%) and absolute diameters (22%). Mean maximal diameter was 4.51 ± 0.99 mm. At 5‑year follow-up target vessel failure rates were 24.1% in the total cohort (DES 22.8% vs. BMS 33%, p = 0.26). Definite stent thrombosis rate was 3.8% at 5‑year follow-up in this cohort with complex and high-risk lesions (DES 4.5% vs. BMS 0%, p = 0.39). CONCLUSIONS: Angiographic indications for the use of the self-apposing stent were complex lesions with atypical coronary anatomy. Our data showed reasonable stent thrombosis rates at 5‑year follow-up, considering the high-risk lesion characteristics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12471-018-1111-7) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5910317 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-59103172018-04-24 Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications Lu, H. Bekker, R. J. Grundeken, M. J. Woudstra, P. Wykrzykowska, J. J. Tijssen, J. G. P. de Winter, R. J. Koch, K. T. Neth Heart J Original Article OBJECTIVES: We sought to investigate angiographic indications for the use of the STENTYS technique and evaluated the long-term safety and clinical efficacy of the stent. BACKGROUND: Coronary lesions involving complex anatomy, including aneurysmatic, ectatic, or tapered vessel segments often carry a substantial risk of stent malapposition. The self-apposing stent technique may reduce the risk of stent malapposition and therefore improve clinical outcomes. METHODS: A total of 120 consecutive patients treated with the STENTYS stent were included (drug-eluting stent (DES) n = 101, bare-metal stent (BMS) n = 19). All lesions were scored for angiographic indications for the STENTYS stent, including aneurysms, ectasias, tapering, absolute diameters, bifurcation lesions, and saphenous vein grafts. Off-line quantitative coronary angiography analyses were performed pre-procedure and post-procedure. Five years follow-up was obtained including cardiac death, target vessel myocardial infarction (TV-MI), target vessel revascularisation, stent thrombosis, and the composite endpoint target vessel failure (cardiac death, TV-MI and target vessel revascularisation). RESULTS: Angiographic indications for STENTYS use were aneurysm (30%), ectasia (19%), tapering (27%), bifurcation lesions (8%), and saphenous vein graft lesions (16%) and absolute diameters (22%). Mean maximal diameter was 4.51 ± 0.99 mm. At 5‑year follow-up target vessel failure rates were 24.1% in the total cohort (DES 22.8% vs. BMS 33%, p = 0.26). Definite stent thrombosis rate was 3.8% at 5‑year follow-up in this cohort with complex and high-risk lesions (DES 4.5% vs. BMS 0%, p = 0.39). CONCLUSIONS: Angiographic indications for the use of the self-apposing stent were complex lesions with atypical coronary anatomy. Our data showed reasonable stent thrombosis rates at 5‑year follow-up, considering the high-risk lesion characteristics. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12471-018-1111-7) contains supplementary material, which is available to authorized users. Bohn Stafleu van Loghum 2018-04-13 2018-05 /pmc/articles/PMC5910317/ /pubmed/29654515 http://dx.doi.org/10.1007/s12471-018-1111-7 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Lu, H. Bekker, R. J. Grundeken, M. J. Woudstra, P. Wykrzykowska, J. J. Tijssen, J. G. P. de Winter, R. J. Koch, K. T. Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
title | Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
title_full | Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
title_fullStr | Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
title_full_unstemmed | Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
title_short | Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
title_sort | five-year clinical follow-up of the stentys self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5910317/ https://www.ncbi.nlm.nih.gov/pubmed/29654515 http://dx.doi.org/10.1007/s12471-018-1111-7 |
work_keys_str_mv | AT luh fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT bekkerrj fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT grundekenmj fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT woudstrap fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT wykrzykowskajj fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT tijssenjgp fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT dewinterrj fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications AT kochkt fiveyearclinicalfollowupofthestentysselfapposingstentincomplexcoronaryanatomyasinglecentreexperiencewithreportofspecificangiographicindications |