Cargando…
Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre
INTRODUCTION: Manufacturers offer gutta-percha (GP) cones matched with different sizes of endodontic files as an attempt to simplify the obturation process and create a tight seal in the canal. The purpose of this study was to evaluate whether intra-manufacture GP diameters matched the diameters of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5911287/ https://www.ncbi.nlm.nih.gov/pubmed/29707008 http://dx.doi.org/10.22037/iej.v13i2.14710 |
_version_ | 1783316183931420672 |
---|---|
author | Mirmohammadi, Hesam Sitarz, Monika Shemesh, Hagay |
author_facet | Mirmohammadi, Hesam Sitarz, Monika Shemesh, Hagay |
author_sort | Mirmohammadi, Hesam |
collection | PubMed |
description | INTRODUCTION: Manufacturers offer gutta-percha (GP) cones matched with different sizes of endodontic files as an attempt to simplify the obturation process and create a tight seal in the canal. The purpose of this study was to evaluate whether intra-manufacture GP diameters matched the diameters of their corresponding files at different levels using laser micrometre. METHODS AND MATERIALS: Twenty files and corresponding GP master cones of Reciproc R40 (40/0.06) (VDW, Munich, Germany), WaveOne Large(40/0.08)(Dentsply Maillefer, Ballaigues, Switzerland), ProTaper F3 (30/0.09) (Dentsply Maillefer, Ballaigues, Switzerland), and Mtwo 40/0.06 (VDW, Munich, Germany) were examined using laser micrometre (LSM 6000 by Mitutoyo, Japan) with accuracy of 1 nm to establish their actual diameter at D(0), D(1), D(3) and D(6). The data was analysed using the independent t-test. The differences were considered at 0.05. RESULTS: The diameter of GP master cones was significantly larger than that of the corresponding files at all levels in all brands. ProTaper GP diameter was closest to the file diameter at D1 (GP=0.35, File=0.35 mm), and D3 (GP=0.48, File=0.49). CONCLUSION: Within the same manufacturer, GP cone diameters do not match the diameters of their corresponding files. Clinicians are advised to use a GP gauge to cut the tip so as to appropriate the diameter from a smaller sized GP cone. |
format | Online Article Text |
id | pubmed-5911287 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-59112872018-04-27 Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre Mirmohammadi, Hesam Sitarz, Monika Shemesh, Hagay Iran Endod J Original Article INTRODUCTION: Manufacturers offer gutta-percha (GP) cones matched with different sizes of endodontic files as an attempt to simplify the obturation process and create a tight seal in the canal. The purpose of this study was to evaluate whether intra-manufacture GP diameters matched the diameters of their corresponding files at different levels using laser micrometre. METHODS AND MATERIALS: Twenty files and corresponding GP master cones of Reciproc R40 (40/0.06) (VDW, Munich, Germany), WaveOne Large(40/0.08)(Dentsply Maillefer, Ballaigues, Switzerland), ProTaper F3 (30/0.09) (Dentsply Maillefer, Ballaigues, Switzerland), and Mtwo 40/0.06 (VDW, Munich, Germany) were examined using laser micrometre (LSM 6000 by Mitutoyo, Japan) with accuracy of 1 nm to establish their actual diameter at D(0), D(1), D(3) and D(6). The data was analysed using the independent t-test. The differences were considered at 0.05. RESULTS: The diameter of GP master cones was significantly larger than that of the corresponding files at all levels in all brands. ProTaper GP diameter was closest to the file diameter at D1 (GP=0.35, File=0.35 mm), and D3 (GP=0.48, File=0.49). CONCLUSION: Within the same manufacturer, GP cone diameters do not match the diameters of their corresponding files. Clinicians are advised to use a GP gauge to cut the tip so as to appropriate the diameter from a smaller sized GP cone. Iranian Center for Endodontic Research 2018 /pmc/articles/PMC5911287/ /pubmed/29707008 http://dx.doi.org/10.22037/iej.v13i2.14710 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mirmohammadi, Hesam Sitarz, Monika Shemesh, Hagay Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre |
title | Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre |
title_full | Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre |
title_fullStr | Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre |
title_full_unstemmed | Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre |
title_short | Intra-manufacture Diameter Variability of Rotary Files and Their Corresponding Gutta-Percha Cones Using Laser Scan Micrometre |
title_sort | intra-manufacture diameter variability of rotary files and their corresponding gutta-percha cones using laser scan micrometre |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5911287/ https://www.ncbi.nlm.nih.gov/pubmed/29707008 http://dx.doi.org/10.22037/iej.v13i2.14710 |
work_keys_str_mv | AT mirmohammadihesam intramanufacturediametervariabilityofrotaryfilesandtheircorrespondingguttaperchaconesusinglaserscanmicrometre AT sitarzmonika intramanufacturediametervariabilityofrotaryfilesandtheircorrespondingguttaperchaconesusinglaserscanmicrometre AT shemeshhagay intramanufacturediametervariabilityofrotaryfilesandtheircorrespondingguttaperchaconesusinglaserscanmicrometre |