Cargando…
Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model
STUDY DESIGN: Experimental study in an animal model. PURPOSE: This study aims to evaluate the hemostatic properties of four common hemostatic materials including the chitosan clot pad, absorbable gelatin sponge, cellulose membrane, and gauze on peridural bleeding using a rat model. OVERVIEW OF LITER...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Spine Surgery
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5913009/ https://www.ncbi.nlm.nih.gov/pubmed/29713399 http://dx.doi.org/10.4184/asj.2018.12.2.195 |
_version_ | 1783316450819178496 |
---|---|
author | Sae-Jung, Surachai Apiwatanakul, Punyawat |
author_facet | Sae-Jung, Surachai Apiwatanakul, Punyawat |
author_sort | Sae-Jung, Surachai |
collection | PubMed |
description | STUDY DESIGN: Experimental study in an animal model. PURPOSE: This study aims to evaluate the hemostatic properties of four common hemostatic materials including the chitosan clot pad, absorbable gelatin sponge, cellulose membrane, and gauze on peridural bleeding using a rat model. OVERVIEW OF LITERATURE: Intraoperative bleeding during spinal surgery can lead to morbidities. Hemostatic materials have been developed, but the efficacy of these materials on peridural bleeding remains unclear. METHODS: Forty 8-week-old Sprague-Dawley rats were used in this study. Under adequate anesthesia, each rat was posteriorly dissected to their L5 and L6 spinous processes. Bleeding from muscles and soft tissue dissections was stopped before lumbar bone cutting. Immediately after the L5–L6 laminae were cut and removed, the rats were randomly allocated to receive one of the abovementioned hemostatic materials. All hemostatic materials were placed over the raw surface of cut bone and dura and changed every 60 seconds. The procedure was stopped when there was no further bleeding. Time to staunching and amount of bleeding were recorded for statistical analysis. RESULTS: The respective mean±standard deviation hemorrhage volume and time for the cellulose membrane, gelatin sponge, chitosan pad, and gauze were 1.19±0.44, 1.03±0.72, 0.96±0.57, and 1.98±0.62 mL, respectively, and 2.9±0.6, 2.1±0.6, 1.7±0.5, and 2.9±1.0 minutes, respectively. The overall bleeding volumes for the cellulose membrane, gelatin sponge, and chitosan pad were significantly lower than the overall bleeding volume for gauze. CONCLUSIONS: Chitosan clot pads, gelatin sponges, and cellulose membranes have better hemostatic properties than gauze. The chitosan pad had the lowest average bleeding volume, followed by gelatin sponge and cellulose membrane. |
format | Online Article Text |
id | pubmed-5913009 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Korean Society of Spine Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-59130092018-04-30 Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model Sae-Jung, Surachai Apiwatanakul, Punyawat Asian Spine J Basic Study STUDY DESIGN: Experimental study in an animal model. PURPOSE: This study aims to evaluate the hemostatic properties of four common hemostatic materials including the chitosan clot pad, absorbable gelatin sponge, cellulose membrane, and gauze on peridural bleeding using a rat model. OVERVIEW OF LITERATURE: Intraoperative bleeding during spinal surgery can lead to morbidities. Hemostatic materials have been developed, but the efficacy of these materials on peridural bleeding remains unclear. METHODS: Forty 8-week-old Sprague-Dawley rats were used in this study. Under adequate anesthesia, each rat was posteriorly dissected to their L5 and L6 spinous processes. Bleeding from muscles and soft tissue dissections was stopped before lumbar bone cutting. Immediately after the L5–L6 laminae were cut and removed, the rats were randomly allocated to receive one of the abovementioned hemostatic materials. All hemostatic materials were placed over the raw surface of cut bone and dura and changed every 60 seconds. The procedure was stopped when there was no further bleeding. Time to staunching and amount of bleeding were recorded for statistical analysis. RESULTS: The respective mean±standard deviation hemorrhage volume and time for the cellulose membrane, gelatin sponge, chitosan pad, and gauze were 1.19±0.44, 1.03±0.72, 0.96±0.57, and 1.98±0.62 mL, respectively, and 2.9±0.6, 2.1±0.6, 1.7±0.5, and 2.9±1.0 minutes, respectively. The overall bleeding volumes for the cellulose membrane, gelatin sponge, and chitosan pad were significantly lower than the overall bleeding volume for gauze. CONCLUSIONS: Chitosan clot pads, gelatin sponges, and cellulose membranes have better hemostatic properties than gauze. The chitosan pad had the lowest average bleeding volume, followed by gelatin sponge and cellulose membrane. Korean Society of Spine Surgery 2018-04 2018-04-16 /pmc/articles/PMC5913009/ /pubmed/29713399 http://dx.doi.org/10.4184/asj.2018.12.2.195 Text en Copyright © 2018 by Korean Society of Spine Surgery http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Basic Study Sae-Jung, Surachai Apiwatanakul, Punyawat Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model |
title | Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model |
title_full | Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model |
title_fullStr | Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model |
title_full_unstemmed | Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model |
title_short | Chitosan Pad, Cellulose Membrane, or Gelatin Sponge for Peridural Bleeding: An Efficacy Study on a Lumbar Laminectomized Rat Model |
title_sort | chitosan pad, cellulose membrane, or gelatin sponge for peridural bleeding: an efficacy study on a lumbar laminectomized rat model |
topic | Basic Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5913009/ https://www.ncbi.nlm.nih.gov/pubmed/29713399 http://dx.doi.org/10.4184/asj.2018.12.2.195 |
work_keys_str_mv | AT saejungsurachai chitosanpadcellulosemembraneorgelatinspongeforperiduralbleedinganefficacystudyonalumbarlaminectomizedratmodel AT apiwatanakulpunyawat chitosanpadcellulosemembraneorgelatinspongeforperiduralbleedinganefficacystudyonalumbarlaminectomizedratmodel |