Cargando…

Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review

OBJECTIVES: The purpose of the present study is to systematically review the accuracy of implant placement with mucosa-supported stereolithographic surgical guide and to find out what factors can influence the accuracy. MATERIAL AND METHODS: An electronic literature search was performed through the...

Descripción completa

Detalles Bibliográficos
Autores principales: Seo, Cheongbeom, Juodzbalys, Gintaras
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Stilus Optimus 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5913414/
https://www.ncbi.nlm.nih.gov/pubmed/29707180
http://dx.doi.org/10.5037/jomr.2018.9101
_version_ 1783316537432604672
author Seo, Cheongbeom
Juodzbalys, Gintaras
author_facet Seo, Cheongbeom
Juodzbalys, Gintaras
author_sort Seo, Cheongbeom
collection PubMed
description OBJECTIVES: The purpose of the present study is to systematically review the accuracy of implant placement with mucosa-supported stereolithographic surgical guide and to find out what factors can influence the accuracy. MATERIAL AND METHODS: An electronic literature search was performed through the MEDLINE (PubMed) and EMBASE databases. The articles are including human studies published in English from October 2008 to October, 2017. From the examination of selected articles, deviations between virtual planning and actual implant placement were analysed regarding the global apical, global coronal, and angulation position. RESULTS: A total of 119 articles were reviewed, and 6 of the most relevant articles that are suitable to the criteria were selected. The present data included 572 implants and 93 patients. The result in the present systematic review shows that mean apical global deviation ranges from 0.67 (SD 0.34) mm to 2.19 (SD 0.83) mm, mean coronal global deviation ranges from 0.6 (SD 0.25) mm to 1.68 (SD 0.25) mm and mean angular deviation - from 2.6° (SD 1.61°) to 4.67° (SD 2.68°). CONCLUSIONS: It's clearly shown from most of the examined studies that the mucosa-supported stereolithographic surgical guide, showed not exceeding in apically 2.19 mm, in coronally 1.68 mm and in angular deviation 4.67°. Surgeons should be aware of the possible linear and angular deviations of the system. Accuracy can be influenced by bone density, mucosal thickness, surgical techniques, type of jaw, smoking habits and implant length. Further studies should be performed in order to find out which jaw can have better accuracy and how the experience can influence the accuracy.
format Online
Article
Text
id pubmed-5913414
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Stilus Optimus
record_format MEDLINE/PubMed
spelling pubmed-59134142018-04-27 Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review Seo, Cheongbeom Juodzbalys, Gintaras J Oral Maxillofac Res Literature Review/ OBJECTIVES: The purpose of the present study is to systematically review the accuracy of implant placement with mucosa-supported stereolithographic surgical guide and to find out what factors can influence the accuracy. MATERIAL AND METHODS: An electronic literature search was performed through the MEDLINE (PubMed) and EMBASE databases. The articles are including human studies published in English from October 2008 to October, 2017. From the examination of selected articles, deviations between virtual planning and actual implant placement were analysed regarding the global apical, global coronal, and angulation position. RESULTS: A total of 119 articles were reviewed, and 6 of the most relevant articles that are suitable to the criteria were selected. The present data included 572 implants and 93 patients. The result in the present systematic review shows that mean apical global deviation ranges from 0.67 (SD 0.34) mm to 2.19 (SD 0.83) mm, mean coronal global deviation ranges from 0.6 (SD 0.25) mm to 1.68 (SD 0.25) mm and mean angular deviation - from 2.6° (SD 1.61°) to 4.67° (SD 2.68°). CONCLUSIONS: It's clearly shown from most of the examined studies that the mucosa-supported stereolithographic surgical guide, showed not exceeding in apically 2.19 mm, in coronally 1.68 mm and in angular deviation 4.67°. Surgeons should be aware of the possible linear and angular deviations of the system. Accuracy can be influenced by bone density, mucosal thickness, surgical techniques, type of jaw, smoking habits and implant length. Further studies should be performed in order to find out which jaw can have better accuracy and how the experience can influence the accuracy. Stilus Optimus 2018-03-31 /pmc/articles/PMC5913414/ /pubmed/29707180 http://dx.doi.org/10.5037/jomr.2018.9101 Text en Copyright © Seo C, Juodzbalys G. Published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH (http://www.ejomr.org), 31 March 2018. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article, first published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 UnportedLicense (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work and is properly cited. The copyright, license information and link to the original publication on (http://www.ejomr.org) must be included.
spellingShingle Literature Review/
Seo, Cheongbeom
Juodzbalys, Gintaras
Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review
title Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review
title_full Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review
title_fullStr Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review
title_full_unstemmed Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review
title_short Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: a Systematic Review
title_sort accuracy of guided surgery via stereolithographic mucosa-supported surgical guide in implant surgery for edentulous patient: a systematic review
topic Literature Review/
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5913414/
https://www.ncbi.nlm.nih.gov/pubmed/29707180
http://dx.doi.org/10.5037/jomr.2018.9101
work_keys_str_mv AT seocheongbeom accuracyofguidedsurgeryviastereolithographicmucosasupportedsurgicalguideinimplantsurgeryforedentulouspatientasystematicreview
AT juodzbalysgintaras accuracyofguidedsurgeryviastereolithographicmucosasupportedsurgicalguideinimplantsurgeryforedentulouspatientasystematicreview