Cargando…

Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source

We report on the use of a single supercontinuum (SC) source for multimodal imaging. The 2-octave bandwidth (475–2300 nm) makes the SC source suitable for optical coherence tomography (OCT) as well as for multispectral photoacoustic microscopy (MPAM). The IR band centered at 1310 nm is chosen for OCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Bondu, M., Marques, M.J., Moselund, P.M., Lall, G., Bradu, A., Podoleanu, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5914199/
https://www.ncbi.nlm.nih.gov/pubmed/29707477
http://dx.doi.org/10.1016/j.pacs.2017.11.002
_version_ 1783316666935934976
author Bondu, M.
Marques, M.J.
Moselund, P.M.
Lall, G.
Bradu, A.
Podoleanu, A.
author_facet Bondu, M.
Marques, M.J.
Moselund, P.M.
Lall, G.
Bradu, A.
Podoleanu, A.
author_sort Bondu, M.
collection PubMed
description We report on the use of a single supercontinuum (SC) source for multimodal imaging. The 2-octave bandwidth (475–2300 nm) makes the SC source suitable for optical coherence tomography (OCT) as well as for multispectral photoacoustic microscopy (MPAM). The IR band centered at 1310 nm is chosen for OCT to penetrate deeper into tissue with 8 mW average power on the sample. The 500–840 nm band is used for MPAM. The source has the ability to select the central wavelength as well as the spectral bandwidth. An energy of more than 35 nJ within a less than 50 nm bandwidth is achieved on the sample for wavelengths longer than 500 nm. In the present paper, we demonstrate the capabilities of such a multimodality imaging instrument based on a single optical source. In vitro mouse ear B-scan images are presented.
format Online
Article
Text
id pubmed-5914199
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-59141992018-04-27 Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source Bondu, M. Marques, M.J. Moselund, P.M. Lall, G. Bradu, A. Podoleanu, A. Photoacoustics Research Article We report on the use of a single supercontinuum (SC) source for multimodal imaging. The 2-octave bandwidth (475–2300 nm) makes the SC source suitable for optical coherence tomography (OCT) as well as for multispectral photoacoustic microscopy (MPAM). The IR band centered at 1310 nm is chosen for OCT to penetrate deeper into tissue with 8 mW average power on the sample. The 500–840 nm band is used for MPAM. The source has the ability to select the central wavelength as well as the spectral bandwidth. An energy of more than 35 nJ within a less than 50 nm bandwidth is achieved on the sample for wavelengths longer than 500 nm. In the present paper, we demonstrate the capabilities of such a multimodality imaging instrument based on a single optical source. In vitro mouse ear B-scan images are presented. Elsevier 2017-11-26 /pmc/articles/PMC5914199/ /pubmed/29707477 http://dx.doi.org/10.1016/j.pacs.2017.11.002 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Bondu, M.
Marques, M.J.
Moselund, P.M.
Lall, G.
Bradu, A.
Podoleanu, A.
Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
title Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
title_full Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
title_fullStr Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
title_full_unstemmed Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
title_short Multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
title_sort multispectral photoacoustic microscopy and optical coherence tomography using a single supercontinuum source
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5914199/
https://www.ncbi.nlm.nih.gov/pubmed/29707477
http://dx.doi.org/10.1016/j.pacs.2017.11.002
work_keys_str_mv AT bondum multispectralphotoacousticmicroscopyandopticalcoherencetomographyusingasinglesupercontinuumsource
AT marquesmj multispectralphotoacousticmicroscopyandopticalcoherencetomographyusingasinglesupercontinuumsource
AT moselundpm multispectralphotoacousticmicroscopyandopticalcoherencetomographyusingasinglesupercontinuumsource
AT lallg multispectralphotoacousticmicroscopyandopticalcoherencetomographyusingasinglesupercontinuumsource
AT bradua multispectralphotoacousticmicroscopyandopticalcoherencetomographyusingasinglesupercontinuumsource
AT podoleanua multispectralphotoacousticmicroscopyandopticalcoherencetomographyusingasinglesupercontinuumsource