Cargando…
Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs
ABSTRACT: X-ray analysis confirmed that in all investigated samples, the active API (acetylsalicylic acid and ascorbic acid) was present. The values of the interplanar distance d(hkl) for the studied samples are in good accordance with those presented in the ICDD database. The intensities of the dif...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Vienna
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5915495/ https://www.ncbi.nlm.nih.gov/pubmed/29720770 http://dx.doi.org/10.1007/s00706-018-2193-z |
_version_ | 1783316873519038464 |
---|---|
author | Jendrzejewska, Izabela Zajdel, Paweł Pietrasik, Ewa Barsova, Zoja Goryczka, Tomasz |
author_facet | Jendrzejewska, Izabela Zajdel, Paweł Pietrasik, Ewa Barsova, Zoja Goryczka, Tomasz |
author_sort | Jendrzejewska, Izabela |
collection | PubMed |
description | ABSTRACT: X-ray analysis confirmed that in all investigated samples, the active API (acetylsalicylic acid and ascorbic acid) was present. The values of the interplanar distance d(hkl) for the studied samples are in good accordance with those presented in the ICDD database. The intensities of the diffraction lines depend on the content of the component in the tested preparation. Therefore, different intensities of lines for the APIs were observed in the obtained diffraction patterns. Thermal analysis of the studied substances showed that during the thermal analysis, the following phenomena might occur: dehydration and (or) melting, crystalline transformation. Moreover, it was found that the chemical structure of the studied compounds affects the process of their thermal decomposition. The data obtained during these investigations can be useful in quick tests of physicochemical discrepancies and abnormalities between potential components of pharmaceutical preparations. The evidence for the interaction can be obtained by comparing DSC and TG curves of the drug and the excipient, as well as those of their physical mixtures. For this reason, the study of characteristics of thermal decomposition of drugs and excipients is necessary. Based on the above investigations, it may be stated that a combination of two methods: XRPD and DSC can be used to distinguish the original drugs from counterfeit products, e.g., by checking for the presence of the correct API or by a comparison of the drugs fingerprint. GRAPHICAL ABSTRACT: [Image: see text] |
format | Online Article Text |
id | pubmed-5915495 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Vienna |
record_format | MEDLINE/PubMed |
spelling | pubmed-59154952018-04-30 Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs Jendrzejewska, Izabela Zajdel, Paweł Pietrasik, Ewa Barsova, Zoja Goryczka, Tomasz Monatsh Chem Original Paper ABSTRACT: X-ray analysis confirmed that in all investigated samples, the active API (acetylsalicylic acid and ascorbic acid) was present. The values of the interplanar distance d(hkl) for the studied samples are in good accordance with those presented in the ICDD database. The intensities of the diffraction lines depend on the content of the component in the tested preparation. Therefore, different intensities of lines for the APIs were observed in the obtained diffraction patterns. Thermal analysis of the studied substances showed that during the thermal analysis, the following phenomena might occur: dehydration and (or) melting, crystalline transformation. Moreover, it was found that the chemical structure of the studied compounds affects the process of their thermal decomposition. The data obtained during these investigations can be useful in quick tests of physicochemical discrepancies and abnormalities between potential components of pharmaceutical preparations. The evidence for the interaction can be obtained by comparing DSC and TG curves of the drug and the excipient, as well as those of their physical mixtures. For this reason, the study of characteristics of thermal decomposition of drugs and excipients is necessary. Based on the above investigations, it may be stated that a combination of two methods: XRPD and DSC can be used to distinguish the original drugs from counterfeit products, e.g., by checking for the presence of the correct API or by a comparison of the drugs fingerprint. GRAPHICAL ABSTRACT: [Image: see text] Springer Vienna 2018-04-10 2018 /pmc/articles/PMC5915495/ /pubmed/29720770 http://dx.doi.org/10.1007/s00706-018-2193-z Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Paper Jendrzejewska, Izabela Zajdel, Paweł Pietrasik, Ewa Barsova, Zoja Goryczka, Tomasz Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
title | Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
title_full | Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
title_fullStr | Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
title_full_unstemmed | Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
title_short | Application of X-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
title_sort | application of x-ray powder diffraction and differential scanning calorimetry for identification of counterfeit drugs |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5915495/ https://www.ncbi.nlm.nih.gov/pubmed/29720770 http://dx.doi.org/10.1007/s00706-018-2193-z |
work_keys_str_mv | AT jendrzejewskaizabela applicationofxraypowderdiffractionanddifferentialscanningcalorimetryforidentificationofcounterfeitdrugs AT zajdelpaweł applicationofxraypowderdiffractionanddifferentialscanningcalorimetryforidentificationofcounterfeitdrugs AT pietrasikewa applicationofxraypowderdiffractionanddifferentialscanningcalorimetryforidentificationofcounterfeitdrugs AT barsovazoja applicationofxraypowderdiffractionanddifferentialscanningcalorimetryforidentificationofcounterfeitdrugs AT goryczkatomasz applicationofxraypowderdiffractionanddifferentialscanningcalorimetryforidentificationofcounterfeitdrugs |