Prosthetic liner wear in total hip replacement: a longitudinal 13-year study with computed tomography
This case report follows a woman who had a total hip replacement in 1992 when she was 45 years old. Six serial computed tomography (CT) examinations over a period of 13 years provided information that allowed her revision surgery to be limited to liner replacement as opposed to replacement of the en...
Autores principales: | Weidenhielm, Lars, Olivecrona, Henrik, Maguire, Gerald Q., Noz, Marilyn E. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5915507/ https://www.ncbi.nlm.nih.gov/pubmed/29362844 http://dx.doi.org/10.1007/s00256-018-2878-8 |
Ejemplares similares
-
A CT method for following patients with both prosthetic replacement and implanted tantalum beads: preliminary analysis with a pelvic model and in seven patients
por: Olivecrona, Henrik, et al.
Publicado: (2016) -
A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis
por: Maguire Jr., Gerald Q., et al.
Publicado: (2014) -
In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty: Comparison of measurements using a CT algorithm, a coordinate-measuring machine, and a micrometer
por: Goldvasser, Dov, et al.
Publicado: (2014) -
A New CT Method for Assessing 3D Movements in Lumbar Facet Joints and Vertebrae in Patients before and after TDR
por: Svedmark, Per, et al.
Publicado: (2015) -
Risk Factors for Periacetabular Osteolysis and Wear in Asymptomatic Patients with Uncemented Total Hip Arthroplasties
por: Sandgren, Buster, et al.
Publicado: (2014)