Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

PURPOSE: This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS: Forty maxillary complete-arch prostheses were randomly divided into four gro...

Descripción completa

Detalles Bibliográficos
Autores principales: Lima, Ana Paula Barbosa, Vitti, Rafael Pino, Amaral, Marina, Neves, Ana Christina Claro, da Silva Concilio, Lais Regiane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917103/
https://www.ncbi.nlm.nih.gov/pubmed/29713432
http://dx.doi.org/10.4047/jap.2018.10.2.122
_version_ 1783317129666232320
author Lima, Ana Paula Barbosa
Vitti, Rafael Pino
Amaral, Marina
Neves, Ana Christina Claro
da Silva Concilio, Lais Regiane
author_facet Lima, Ana Paula Barbosa
Vitti, Rafael Pino
Amaral, Marina
Neves, Ana Christina Claro
da Silva Concilio, Lais Regiane
author_sort Lima, Ana Paula Barbosa
collection PubMed
description PURPOSE: This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS: Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). RESULTS: he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION: The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.
format Online
Article
Text
id pubmed-5917103
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-59171032018-04-30 Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis Lima, Ana Paula Barbosa Vitti, Rafael Pino Amaral, Marina Neves, Ana Christina Claro da Silva Concilio, Lais Regiane J Adv Prosthodont Original Article PURPOSE: This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS: Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). RESULTS: he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION: The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis. The Korean Academy of Prosthodontics 2018-04 2018-04-18 /pmc/articles/PMC5917103/ /pubmed/29713432 http://dx.doi.org/10.4047/jap.2018.10.2.122 Text en © 2018 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lima, Ana Paula Barbosa
Vitti, Rafael Pino
Amaral, Marina
Neves, Ana Christina Claro
da Silva Concilio, Lais Regiane
Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
title Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
title_full Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
title_fullStr Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
title_full_unstemmed Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
title_short Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
title_sort effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917103/
https://www.ncbi.nlm.nih.gov/pubmed/29713432
http://dx.doi.org/10.4047/jap.2018.10.2.122
work_keys_str_mv AT limaanapaulabarbosa effectofpolymerizationmethodandfabricationmethodonocclusalverticaldimensionandocclusalcontactsofcompletearchprosthesis
AT vittirafaelpino effectofpolymerizationmethodandfabricationmethodonocclusalverticaldimensionandocclusalcontactsofcompletearchprosthesis
AT amaralmarina effectofpolymerizationmethodandfabricationmethodonocclusalverticaldimensionandocclusalcontactsofcompletearchprosthesis
AT nevesanachristinaclaro effectofpolymerizationmethodandfabricationmethodonocclusalverticaldimensionandocclusalcontactsofcompletearchprosthesis
AT dasilvaconciliolaisregiane effectofpolymerizationmethodandfabricationmethodonocclusalverticaldimensionandocclusalcontactsofcompletearchprosthesis