Cargando…
Three-dimensional finite element analysis of the splinted implant prosthesis in a reconstructed mandible
PURPOSE: The purpose of this study was to analyze the effects of the splinted implant prosthesis in a reconstructed mandible using three-dimensional finite element analysis. MATERIALS AND METHODS: Three-dimensional finite element models were generated from a patient's computed tomography data....
Autores principales: | Heo, Kyung-Hoi, Lim, Young-Jun, Kim, Myung-Joo, Kwon, Ho-Beom |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917106/ https://www.ncbi.nlm.nih.gov/pubmed/29713435 http://dx.doi.org/10.4047/jap.2018.10.2.138 |
Ejemplares similares
-
Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible
por: Alom, Ghaith, et al.
Publicado: (2021) -
3D Finite Element Study on: Bar Splinted Implants Supporting Partial Denture in the Reconstructed Mandible
por: El-Anwar, Mohamed, et al.
Publicado: (2016) -
Three-dimensional finite element analysis of platform switched implant
por: Moon, Se-Young, et al.
Publicado: (2017) -
A Nonlinear Three-Dimensional Finite Element Analysis of Stress Distribution and Microstrain Evaluation in Short Dental Implants with Three Different Implant–Abutment Connections in Single and Splinted Conditions in the Posterior Mandible
por: Talreja, Karishma S., et al.
Publicado: (2023) -
Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis
por: Lemos, Cleidiel Aparecido Araujo, et al.
Publicado: (2018)