Cargando…
The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
BACKGROUND: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults. PATIE...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Images in Paediatric Cardiology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917869/ https://www.ncbi.nlm.nih.gov/pubmed/29731788 |
_version_ | 1783317307281375232 |
---|---|
author | Aquilina, A Aquilina, O Sammut, M Grech, V |
author_facet | Aquilina, A Aquilina, O Sammut, M Grech, V |
author_sort | Aquilina, A |
collection | PubMed |
description | BACKGROUND: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults. PATIENT DESCRIPTION: We describe an asymptomatic 20-month-old boy, noted to have incidental bradycardia on routine examination and in whom Holter monitoring revealed complete heart block (CHB). Over 1 year, the longest recorded pause lengthened from 1.8 seconds to 3.6 seconds. RESULTS: The Reveal LINQ™ ICM was inserted for long-term monitoring of the CHB. The device will record the electrocardiogram (ECG) continuously for up to 3 years, freezing in its memory any significant arrhythmic events. This will enable the diagnosis of the longest pauses, confirm whether they are lengthening over time and assist with the decision of pacemaker implantation. CONCLUSION: The Reveal LINQ™ ICM is much smaller than the conventional loop recorder and has been shown to be ideal for close monitoring of asymptomatic yet potentially dangerous arrhythmias in young children. |
format | Online Article Text |
id | pubmed-5917869 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Images in Paediatric Cardiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-59178692018-05-04 The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta Aquilina, A Aquilina, O Sammut, M Grech, V Images Paediatr Cardiol Case Report BACKGROUND: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults. PATIENT DESCRIPTION: We describe an asymptomatic 20-month-old boy, noted to have incidental bradycardia on routine examination and in whom Holter monitoring revealed complete heart block (CHB). Over 1 year, the longest recorded pause lengthened from 1.8 seconds to 3.6 seconds. RESULTS: The Reveal LINQ™ ICM was inserted for long-term monitoring of the CHB. The device will record the electrocardiogram (ECG) continuously for up to 3 years, freezing in its memory any significant arrhythmic events. This will enable the diagnosis of the longest pauses, confirm whether they are lengthening over time and assist with the decision of pacemaker implantation. CONCLUSION: The Reveal LINQ™ ICM is much smaller than the conventional loop recorder and has been shown to be ideal for close monitoring of asymptomatic yet potentially dangerous arrhythmias in young children. Images in Paediatric Cardiology 2017 /pmc/articles/PMC5917869/ /pubmed/29731788 Text en © Images in Paediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Aquilina, A Aquilina, O Sammut, M Grech, V The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta |
title | The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta |
title_full | The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta |
title_fullStr | The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta |
title_full_unstemmed | The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta |
title_short | The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta |
title_sort | first case of the reveal linq™ insertable cardiac monitor implanted in a child in malta |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917869/ https://www.ncbi.nlm.nih.gov/pubmed/29731788 |
work_keys_str_mv | AT aquilinaa thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT aquilinao thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT sammutm thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT grechv thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT aquilinaa firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT aquilinao firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT sammutm firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta AT grechv firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta |