The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta

BACKGROUND: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults. PATIE...

Descripción completa

Detalles Bibliográficos
Autores principales: Aquilina, A, Aquilina, O, Sammut, M, Grech, V
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Images in Paediatric Cardiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917869/
https://www.ncbi.nlm.nih.gov/pubmed/29731788
_version_ 1783317307281375232
author Aquilina, A
Aquilina, O
Sammut, M
Grech, V
author_facet Aquilina, A
Aquilina, O
Sammut, M
Grech, V
author_sort Aquilina, A
collection PubMed
description BACKGROUND: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults. PATIENT DESCRIPTION: We describe an asymptomatic 20-month-old boy, noted to have incidental bradycardia on routine examination and in whom Holter monitoring revealed complete heart block (CHB). Over 1 year, the longest recorded pause lengthened from 1.8 seconds to 3.6 seconds. RESULTS: The Reveal LINQ™ ICM was inserted for long-term monitoring of the CHB. The device will record the electrocardiogram (ECG) continuously for up to 3 years, freezing in its memory any significant arrhythmic events. This will enable the diagnosis of the longest pauses, confirm whether they are lengthening over time and assist with the decision of pacemaker implantation. CONCLUSION: The Reveal LINQ™ ICM is much smaller than the conventional loop recorder and has been shown to be ideal for close monitoring of asymptomatic yet potentially dangerous arrhythmias in young children.
format Online
Article
Text
id pubmed-5917869
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Images in Paediatric Cardiology
record_format MEDLINE/PubMed
spelling pubmed-59178692018-05-04 The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta Aquilina, A Aquilina, O Sammut, M Grech, V Images Paediatr Cardiol Case Report BACKGROUND: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults. PATIENT DESCRIPTION: We describe an asymptomatic 20-month-old boy, noted to have incidental bradycardia on routine examination and in whom Holter monitoring revealed complete heart block (CHB). Over 1 year, the longest recorded pause lengthened from 1.8 seconds to 3.6 seconds. RESULTS: The Reveal LINQ™ ICM was inserted for long-term monitoring of the CHB. The device will record the electrocardiogram (ECG) continuously for up to 3 years, freezing in its memory any significant arrhythmic events. This will enable the diagnosis of the longest pauses, confirm whether they are lengthening over time and assist with the decision of pacemaker implantation. CONCLUSION: The Reveal LINQ™ ICM is much smaller than the conventional loop recorder and has been shown to be ideal for close monitoring of asymptomatic yet potentially dangerous arrhythmias in young children. Images in Paediatric Cardiology 2017 /pmc/articles/PMC5917869/ /pubmed/29731788 Text en © Images in Paediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Aquilina, A
Aquilina, O
Sammut, M
Grech, V
The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
title The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
title_full The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
title_fullStr The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
title_full_unstemmed The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
title_short The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta
title_sort first case of the reveal linq™ insertable cardiac monitor implanted in a child in malta
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917869/
https://www.ncbi.nlm.nih.gov/pubmed/29731788
work_keys_str_mv AT aquilinaa thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT aquilinao thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT sammutm thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT grechv thefirstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT aquilinaa firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT aquilinao firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT sammutm firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta
AT grechv firstcaseofthereveallinqinsertablecardiacmonitorimplantedinachildinmalta