Cargando…
Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea
BACKGROUND: Studies show that the therapeutic CPAP pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients. However, these studies included either CPAP adherent patients using fixed pressure devices, or partly CPAP non-adherent patients using fixed...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5918515/ https://www.ncbi.nlm.nih.gov/pubmed/29067558 http://dx.doi.org/10.1007/s11325-017-1578-2 |
_version_ | 1783317433187041280 |
---|---|
author | Storesund, Anders Johansson, Anders Bjorvatn, Bjørn Lehmann, Sverre |
author_facet | Storesund, Anders Johansson, Anders Bjorvatn, Bjørn Lehmann, Sverre |
author_sort | Storesund, Anders |
collection | PubMed |
description | BACKGROUND: Studies show that the therapeutic CPAP pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients. However, these studies included either CPAP adherent patients using fixed pressure devices, or partly CPAP non-adherent patients using fixed pressure or auto-adjusting (auto-CPAP) devices. In many countries, auto-CPAP is predominately used, and only those non-adherent to therapy need a change to OA. Therefore, studies examining the relationship between CPAP pressures and OA treatment outcome should focus on patients non-adherent to auto-CPAP. PURPOSE: The purpose of this paper is to assess if CPAP pressures predicted OA treatment outcome in patients non-adherent to auto-CPAP therapy. METHODS: The OA treatment responders and non-responders were defined by two success criteria ((1) AHI < 5; (2) 5 ≤ AHI < 10 and > 50% AHI reduction). Logistic regression analyses were performed for CPAP pressures and baseline variables. ROC curve analyses were used to identify CPAP pressure cutoff values, alone and combined with other explanatory variables, predicting the OA treatment outcome. RESULTS: Eighty-seven patients with moderate or severe OSA were included. Maximum CPAP pressures (CPAPmax) were higher in non-responders by both criteria and were, together with baseline AHI, associated with the OA treatment outcome in multivariate regression analyses. ROC curves identified an optimal CPAPmax cutoff of 12 cm H(2)O, corresponding to a positive predictive value (PPV) of 0.85 in predicting non-response using criterion 1. A prediction model combining CPAPmax > 12 and baseline AHI ≥ 30 had a PPV of 1.0 for non-response by both criteria. CONCLUSIONS: Maximum CPAP pressure was a moderate predictor of OA treatment outcome, but combined with baseline AHI, the ability to identify OA non-responders was high. |
format | Online Article Text |
id | pubmed-5918515 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-59185152018-04-30 Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea Storesund, Anders Johansson, Anders Bjorvatn, Bjørn Lehmann, Sverre Sleep Breath Sleep Breathing Physiology and Disorders • Original Article BACKGROUND: Studies show that the therapeutic CPAP pressure is associated with oral appliance (OA) treatment outcome in obstructive sleep apnea (OSA) patients. However, these studies included either CPAP adherent patients using fixed pressure devices, or partly CPAP non-adherent patients using fixed pressure or auto-adjusting (auto-CPAP) devices. In many countries, auto-CPAP is predominately used, and only those non-adherent to therapy need a change to OA. Therefore, studies examining the relationship between CPAP pressures and OA treatment outcome should focus on patients non-adherent to auto-CPAP. PURPOSE: The purpose of this paper is to assess if CPAP pressures predicted OA treatment outcome in patients non-adherent to auto-CPAP therapy. METHODS: The OA treatment responders and non-responders were defined by two success criteria ((1) AHI < 5; (2) 5 ≤ AHI < 10 and > 50% AHI reduction). Logistic regression analyses were performed for CPAP pressures and baseline variables. ROC curve analyses were used to identify CPAP pressure cutoff values, alone and combined with other explanatory variables, predicting the OA treatment outcome. RESULTS: Eighty-seven patients with moderate or severe OSA were included. Maximum CPAP pressures (CPAPmax) were higher in non-responders by both criteria and were, together with baseline AHI, associated with the OA treatment outcome in multivariate regression analyses. ROC curves identified an optimal CPAPmax cutoff of 12 cm H(2)O, corresponding to a positive predictive value (PPV) of 0.85 in predicting non-response using criterion 1. A prediction model combining CPAPmax > 12 and baseline AHI ≥ 30 had a PPV of 1.0 for non-response by both criteria. CONCLUSIONS: Maximum CPAP pressure was a moderate predictor of OA treatment outcome, but combined with baseline AHI, the ability to identify OA non-responders was high. Springer International Publishing 2017-10-24 2018 /pmc/articles/PMC5918515/ /pubmed/29067558 http://dx.doi.org/10.1007/s11325-017-1578-2 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Sleep Breathing Physiology and Disorders • Original Article Storesund, Anders Johansson, Anders Bjorvatn, Bjørn Lehmann, Sverre Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
title | Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
title_full | Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
title_fullStr | Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
title_full_unstemmed | Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
title_short | Oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
title_sort | oral appliance treatment outcome can be predicted by continuous positive airway pressure in moderate to severe obstructive sleep apnea |
topic | Sleep Breathing Physiology and Disorders • Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5918515/ https://www.ncbi.nlm.nih.gov/pubmed/29067558 http://dx.doi.org/10.1007/s11325-017-1578-2 |
work_keys_str_mv | AT storesundanders oralappliancetreatmentoutcomecanbepredictedbycontinuouspositiveairwaypressureinmoderatetosevereobstructivesleepapnea AT johanssonanders oralappliancetreatmentoutcomecanbepredictedbycontinuouspositiveairwaypressureinmoderatetosevereobstructivesleepapnea AT bjorvatnbjørn oralappliancetreatmentoutcomecanbepredictedbycontinuouspositiveairwaypressureinmoderatetosevereobstructivesleepapnea AT lehmannsverre oralappliancetreatmentoutcomecanbepredictedbycontinuouspositiveairwaypressureinmoderatetosevereobstructivesleepapnea |