Cargando…
Measurement of intracellular concentration of fluorescently-labeled targets in living cells
Estimations of intracellular concentrations of fluorescently-labeled molecules within living cells are very important for guidance of biological experiments and interpretation of their results. Here we propose a simple and universal approach for such estimations. The approach is based upon common kn...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5918622/ https://www.ncbi.nlm.nih.gov/pubmed/29694385 http://dx.doi.org/10.1371/journal.pone.0194031 |
_version_ | 1783317457784537088 |
---|---|
author | Cherkas, Volodymyr Grebenyuk, Sergei Osypenko, Denys Dovgan, Alexandr V. Grushevskyi, Eugene O. Yedutenko, Matthew Sheremet, Yevhenii Dromaretsky, Andrew Bozhenko, Arseniy Agashkov, Kirill Kononenko, Nikolai I. Belan, Pavel |
author_facet | Cherkas, Volodymyr Grebenyuk, Sergei Osypenko, Denys Dovgan, Alexandr V. Grushevskyi, Eugene O. Yedutenko, Matthew Sheremet, Yevhenii Dromaretsky, Andrew Bozhenko, Arseniy Agashkov, Kirill Kononenko, Nikolai I. Belan, Pavel |
author_sort | Cherkas, Volodymyr |
collection | PubMed |
description | Estimations of intracellular concentrations of fluorescently-labeled molecules within living cells are very important for guidance of biological experiments and interpretation of their results. Here we propose a simple and universal approach for such estimations. The approach is based upon common knowledge that the dye fluorescence is directly proportional to its quantum yield and the number of its molecules and that a coefficient of proportionality is determined by spectral properties of the dye and optical equipment used to record fluorescent signals. If two fluorescent dyes are present in the same volume, then a ratio of their concentrations is equal to a ratio of their fluorescence multiplied by some dye- and equipment-dependent coefficient. Thus, if the coefficient and concentration of one dye is known then the concentration of another dye can be determined. Here we have demonstrated how to calculate this coefficient (called a ratio factor) and how to use it for concentration measurements of fluorescently tagged molecules. As an example of how this approach can be used, we estimated a concentration of exogenously expressed neuronal Ca(2+) sensor protein, hippocalcin, tagged by a fluorescent protein in a dendritic tree of rat hippocampal neurons loaded via a patch pipette with Alexa Fluor dye of known concentration. The new approach should allow performing a fast, inexpensive and reliable quantitative analysis of fluorescently-labeled targets in different parts of living cells. |
format | Online Article Text |
id | pubmed-5918622 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-59186222018-05-05 Measurement of intracellular concentration of fluorescently-labeled targets in living cells Cherkas, Volodymyr Grebenyuk, Sergei Osypenko, Denys Dovgan, Alexandr V. Grushevskyi, Eugene O. Yedutenko, Matthew Sheremet, Yevhenii Dromaretsky, Andrew Bozhenko, Arseniy Agashkov, Kirill Kononenko, Nikolai I. Belan, Pavel PLoS One Research Article Estimations of intracellular concentrations of fluorescently-labeled molecules within living cells are very important for guidance of biological experiments and interpretation of their results. Here we propose a simple and universal approach for such estimations. The approach is based upon common knowledge that the dye fluorescence is directly proportional to its quantum yield and the number of its molecules and that a coefficient of proportionality is determined by spectral properties of the dye and optical equipment used to record fluorescent signals. If two fluorescent dyes are present in the same volume, then a ratio of their concentrations is equal to a ratio of their fluorescence multiplied by some dye- and equipment-dependent coefficient. Thus, if the coefficient and concentration of one dye is known then the concentration of another dye can be determined. Here we have demonstrated how to calculate this coefficient (called a ratio factor) and how to use it for concentration measurements of fluorescently tagged molecules. As an example of how this approach can be used, we estimated a concentration of exogenously expressed neuronal Ca(2+) sensor protein, hippocalcin, tagged by a fluorescent protein in a dendritic tree of rat hippocampal neurons loaded via a patch pipette with Alexa Fluor dye of known concentration. The new approach should allow performing a fast, inexpensive and reliable quantitative analysis of fluorescently-labeled targets in different parts of living cells. Public Library of Science 2018-04-25 /pmc/articles/PMC5918622/ /pubmed/29694385 http://dx.doi.org/10.1371/journal.pone.0194031 Text en © 2018 Cherkas et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Cherkas, Volodymyr Grebenyuk, Sergei Osypenko, Denys Dovgan, Alexandr V. Grushevskyi, Eugene O. Yedutenko, Matthew Sheremet, Yevhenii Dromaretsky, Andrew Bozhenko, Arseniy Agashkov, Kirill Kononenko, Nikolai I. Belan, Pavel Measurement of intracellular concentration of fluorescently-labeled targets in living cells |
title | Measurement of intracellular concentration of fluorescently-labeled targets in living cells |
title_full | Measurement of intracellular concentration of fluorescently-labeled targets in living cells |
title_fullStr | Measurement of intracellular concentration of fluorescently-labeled targets in living cells |
title_full_unstemmed | Measurement of intracellular concentration of fluorescently-labeled targets in living cells |
title_short | Measurement of intracellular concentration of fluorescently-labeled targets in living cells |
title_sort | measurement of intracellular concentration of fluorescently-labeled targets in living cells |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5918622/ https://www.ncbi.nlm.nih.gov/pubmed/29694385 http://dx.doi.org/10.1371/journal.pone.0194031 |
work_keys_str_mv | AT cherkasvolodymyr measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT grebenyuksergei measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT osypenkodenys measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT dovganalexandrv measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT grushevskyieugeneo measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT yedutenkomatthew measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT sheremetyevhenii measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT dromaretskyandrew measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT bozhenkoarseniy measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT agashkovkirill measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT kononenkonikolaii measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells AT belanpavel measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells |