Cargando…

Measurement of intracellular concentration of fluorescently-labeled targets in living cells

Estimations of intracellular concentrations of fluorescently-labeled molecules within living cells are very important for guidance of biological experiments and interpretation of their results. Here we propose a simple and universal approach for such estimations. The approach is based upon common kn...

Descripción completa

Detalles Bibliográficos
Autores principales: Cherkas, Volodymyr, Grebenyuk, Sergei, Osypenko, Denys, Dovgan, Alexandr V., Grushevskyi, Eugene O., Yedutenko, Matthew, Sheremet, Yevhenii, Dromaretsky, Andrew, Bozhenko, Arseniy, Agashkov, Kirill, Kononenko, Nikolai I., Belan, Pavel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5918622/
https://www.ncbi.nlm.nih.gov/pubmed/29694385
http://dx.doi.org/10.1371/journal.pone.0194031
_version_ 1783317457784537088
author Cherkas, Volodymyr
Grebenyuk, Sergei
Osypenko, Denys
Dovgan, Alexandr V.
Grushevskyi, Eugene O.
Yedutenko, Matthew
Sheremet, Yevhenii
Dromaretsky, Andrew
Bozhenko, Arseniy
Agashkov, Kirill
Kononenko, Nikolai I.
Belan, Pavel
author_facet Cherkas, Volodymyr
Grebenyuk, Sergei
Osypenko, Denys
Dovgan, Alexandr V.
Grushevskyi, Eugene O.
Yedutenko, Matthew
Sheremet, Yevhenii
Dromaretsky, Andrew
Bozhenko, Arseniy
Agashkov, Kirill
Kononenko, Nikolai I.
Belan, Pavel
author_sort Cherkas, Volodymyr
collection PubMed
description Estimations of intracellular concentrations of fluorescently-labeled molecules within living cells are very important for guidance of biological experiments and interpretation of their results. Here we propose a simple and universal approach for such estimations. The approach is based upon common knowledge that the dye fluorescence is directly proportional to its quantum yield and the number of its molecules and that a coefficient of proportionality is determined by spectral properties of the dye and optical equipment used to record fluorescent signals. If two fluorescent dyes are present in the same volume, then a ratio of their concentrations is equal to a ratio of their fluorescence multiplied by some dye- and equipment-dependent coefficient. Thus, if the coefficient and concentration of one dye is known then the concentration of another dye can be determined. Here we have demonstrated how to calculate this coefficient (called a ratio factor) and how to use it for concentration measurements of fluorescently tagged molecules. As an example of how this approach can be used, we estimated a concentration of exogenously expressed neuronal Ca(2+) sensor protein, hippocalcin, tagged by a fluorescent protein in a dendritic tree of rat hippocampal neurons loaded via a patch pipette with Alexa Fluor dye of known concentration. The new approach should allow performing a fast, inexpensive and reliable quantitative analysis of fluorescently-labeled targets in different parts of living cells.
format Online
Article
Text
id pubmed-5918622
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-59186222018-05-05 Measurement of intracellular concentration of fluorescently-labeled targets in living cells Cherkas, Volodymyr Grebenyuk, Sergei Osypenko, Denys Dovgan, Alexandr V. Grushevskyi, Eugene O. Yedutenko, Matthew Sheremet, Yevhenii Dromaretsky, Andrew Bozhenko, Arseniy Agashkov, Kirill Kononenko, Nikolai I. Belan, Pavel PLoS One Research Article Estimations of intracellular concentrations of fluorescently-labeled molecules within living cells are very important for guidance of biological experiments and interpretation of their results. Here we propose a simple and universal approach for such estimations. The approach is based upon common knowledge that the dye fluorescence is directly proportional to its quantum yield and the number of its molecules and that a coefficient of proportionality is determined by spectral properties of the dye and optical equipment used to record fluorescent signals. If two fluorescent dyes are present in the same volume, then a ratio of their concentrations is equal to a ratio of their fluorescence multiplied by some dye- and equipment-dependent coefficient. Thus, if the coefficient and concentration of one dye is known then the concentration of another dye can be determined. Here we have demonstrated how to calculate this coefficient (called a ratio factor) and how to use it for concentration measurements of fluorescently tagged molecules. As an example of how this approach can be used, we estimated a concentration of exogenously expressed neuronal Ca(2+) sensor protein, hippocalcin, tagged by a fluorescent protein in a dendritic tree of rat hippocampal neurons loaded via a patch pipette with Alexa Fluor dye of known concentration. The new approach should allow performing a fast, inexpensive and reliable quantitative analysis of fluorescently-labeled targets in different parts of living cells. Public Library of Science 2018-04-25 /pmc/articles/PMC5918622/ /pubmed/29694385 http://dx.doi.org/10.1371/journal.pone.0194031 Text en © 2018 Cherkas et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Cherkas, Volodymyr
Grebenyuk, Sergei
Osypenko, Denys
Dovgan, Alexandr V.
Grushevskyi, Eugene O.
Yedutenko, Matthew
Sheremet, Yevhenii
Dromaretsky, Andrew
Bozhenko, Arseniy
Agashkov, Kirill
Kononenko, Nikolai I.
Belan, Pavel
Measurement of intracellular concentration of fluorescently-labeled targets in living cells
title Measurement of intracellular concentration of fluorescently-labeled targets in living cells
title_full Measurement of intracellular concentration of fluorescently-labeled targets in living cells
title_fullStr Measurement of intracellular concentration of fluorescently-labeled targets in living cells
title_full_unstemmed Measurement of intracellular concentration of fluorescently-labeled targets in living cells
title_short Measurement of intracellular concentration of fluorescently-labeled targets in living cells
title_sort measurement of intracellular concentration of fluorescently-labeled targets in living cells
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5918622/
https://www.ncbi.nlm.nih.gov/pubmed/29694385
http://dx.doi.org/10.1371/journal.pone.0194031
work_keys_str_mv AT cherkasvolodymyr measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT grebenyuksergei measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT osypenkodenys measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT dovganalexandrv measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT grushevskyieugeneo measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT yedutenkomatthew measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT sheremetyevhenii measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT dromaretskyandrew measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT bozhenkoarseniy measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT agashkovkirill measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT kononenkonikolaii measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells
AT belanpavel measurementofintracellularconcentrationoffluorescentlylabeledtargetsinlivingcells