Cargando…
Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note
Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5920458/ https://www.ncbi.nlm.nih.gov/pubmed/29673199 http://dx.doi.org/10.3390/jcm7040084 |
_version_ | 1783317840467591168 |
---|---|
author | Satarasinghe, Praveen Hamilton, Kojo D. Tarver, Michael J. Buchanan, Robert J. Koltz, Michael T. |
author_facet | Satarasinghe, Praveen Hamilton, Kojo D. Tarver, Michael J. Buchanan, Robert J. Koltz, Michael T. |
author_sort | Satarasinghe, Praveen |
collection | PubMed |
description | Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective. |
format | Online Article Text |
id | pubmed-5920458 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-59204582018-04-30 Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note Satarasinghe, Praveen Hamilton, Kojo D. Tarver, Michael J. Buchanan, Robert J. Koltz, Michael T. J Clin Med Technical Note Object. Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Methods. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Results. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Conclusions. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective. MDPI 2018-04-17 /pmc/articles/PMC5920458/ /pubmed/29673199 http://dx.doi.org/10.3390/jcm7040084 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Technical Note Satarasinghe, Praveen Hamilton, Kojo D. Tarver, Michael J. Buchanan, Robert J. Koltz, Michael T. Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note |
title | Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note |
title_full | Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note |
title_fullStr | Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note |
title_full_unstemmed | Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note |
title_short | Thoracic, Lumbar, and Sacral Pedicle Screw Placement Using Stryker-Ziehm Virtual Screw Technology and Navigated Stryker Cordless Driver 3: Technical Note |
title_sort | thoracic, lumbar, and sacral pedicle screw placement using stryker-ziehm virtual screw technology and navigated stryker cordless driver 3: technical note |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5920458/ https://www.ncbi.nlm.nih.gov/pubmed/29673199 http://dx.doi.org/10.3390/jcm7040084 |
work_keys_str_mv | AT satarasinghepraveen thoraciclumbarandsacralpediclescrewplacementusingstrykerziehmvirtualscrewtechnologyandnavigatedstrykercordlessdriver3technicalnote AT hamiltonkojod thoraciclumbarandsacralpediclescrewplacementusingstrykerziehmvirtualscrewtechnologyandnavigatedstrykercordlessdriver3technicalnote AT tarvermichaelj thoraciclumbarandsacralpediclescrewplacementusingstrykerziehmvirtualscrewtechnologyandnavigatedstrykercordlessdriver3technicalnote AT buchananrobertj thoraciclumbarandsacralpediclescrewplacementusingstrykerziehmvirtualscrewtechnologyandnavigatedstrykercordlessdriver3technicalnote AT koltzmichaelt thoraciclumbarandsacralpediclescrewplacementusingstrykerziehmvirtualscrewtechnologyandnavigatedstrykercordlessdriver3technicalnote |