Cargando…
Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol
We have used fluorescence‐labeled primers and an auto‐sequencer to detect telomerase activity quickly and easily. The current procedure is superior to the original telomeric repeat amplification protocol in several respects: 1) the result is obtained in real time during electrophoresis, 2) semi‐quan...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Blackwell Publishing Ltd
1996
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5921098/ https://www.ncbi.nlm.nih.gov/pubmed/8641961 http://dx.doi.org/10.1111/j.1349-7006.1996.tb00225.x |
_version_ | 1783317937924341760 |
---|---|
author | Ohyashiki, Junko H. Ohyashiki, Kazuma Sano, Tetsuro Toyama, Keisuke |
author_facet | Ohyashiki, Junko H. Ohyashiki, Kazuma Sano, Tetsuro Toyama, Keisuke |
author_sort | Ohyashiki, Junko H. |
collection | PubMed |
description | We have used fluorescence‐labeled primers and an auto‐sequencer to detect telomerase activity quickly and easily. The current procedure is superior to the original telomeric repeat amplification protocol in several respects: 1) the result is obtained in real time during electrophoresis, 2) semi‐quantitative results are possible without using a photo‐capture system, and 3) no radioisotope is needed. |
format | Online Article Text |
id | pubmed-5921098 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1996 |
publisher | Blackwell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-59210982018-05-11 Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol Ohyashiki, Junko H. Ohyashiki, Kazuma Sano, Tetsuro Toyama, Keisuke Jpn J Cancer Res Rapid Communication We have used fluorescence‐labeled primers and an auto‐sequencer to detect telomerase activity quickly and easily. The current procedure is superior to the original telomeric repeat amplification protocol in several respects: 1) the result is obtained in real time during electrophoresis, 2) semi‐quantitative results are possible without using a photo‐capture system, and 3) no radioisotope is needed. Blackwell Publishing Ltd 1996-04 /pmc/articles/PMC5921098/ /pubmed/8641961 http://dx.doi.org/10.1111/j.1349-7006.1996.tb00225.x Text en |
spellingShingle | Rapid Communication Ohyashiki, Junko H. Ohyashiki, Kazuma Sano, Tetsuro Toyama, Keisuke Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol |
title | Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol |
title_full | Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol |
title_fullStr | Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol |
title_full_unstemmed | Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol |
title_short | Non‐radioisotopic and Semi‐quantitative Procedure for Terminal Repeat Amplification Protocol |
title_sort | non‐radioisotopic and semi‐quantitative procedure for terminal repeat amplification protocol |
topic | Rapid Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5921098/ https://www.ncbi.nlm.nih.gov/pubmed/8641961 http://dx.doi.org/10.1111/j.1349-7006.1996.tb00225.x |
work_keys_str_mv | AT ohyashikijunkoh nonradioisotopicandsemiquantitativeprocedureforterminalrepeatamplificationprotocol AT ohyashikikazuma nonradioisotopicandsemiquantitativeprocedureforterminalrepeatamplificationprotocol AT sanotetsuro nonradioisotopicandsemiquantitativeprocedureforterminalrepeatamplificationprotocol AT toyamakeisuke nonradioisotopicandsemiquantitativeprocedureforterminalrepeatamplificationprotocol |