Cargando…

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

BACKGROUND: To enhance the dose to tumor, the use of high atomic number elements has been proposed. OBJECTIVE: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by consid...

Descripción completa

Detalles Bibliográficos
Autores principales: Zabihzadeh, M., Moshirian, T., Ghorbani, M., Knaup, C., Behrooz, M.A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biomedical Physics and Engineering 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5928303/
https://www.ncbi.nlm.nih.gov/pubmed/29732337
_version_ 1783319216204546048
author Zabihzadeh, M.
Moshirian, T.
Ghorbani, M.
Knaup, C.
Behrooz, M.A.
author_facet Zabihzadeh, M.
Moshirian, T.
Ghorbani, M.
Knaup, C.
Behrooz, M.A.
author_sort Zabihzadeh, M.
collection PubMed
description BACKGROUND: To enhance the dose to tumor, the use of high atomic number elements has been proposed. OBJECTIVE: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor. METHODS: MCNP-4C Monte Carlo code was utilized for the simulation of a source, a phantom containing tumor and gold nanoparticles with concentrations of 10, 30 and 70 mg Au/g tumor. A 15 cm×15 cm×15 cm cubic water phantom was irradiated with a small planar source with four monoenergetic X-ray beams of 35, 55, 75 and 95 keV energy. Furthermore, tumor depths of 2.5 cm, 4.5 cm and 6.5 cm with homogeneous and inhomogeneous distributions of nanoparticles were studied. Each concentration, photon energy, tumor depth and type of distribution was evaluated in a separate simulation. RESULTS: Results have shown that dose enhancement factor (DEF) in tumor increases approximately linearly with the concentration of gold nanoparticles. While DEF has fluctuations with photon energy, 55 keV photons have the highest DEF values compared to other energies. While DEF has relatively the same values with tumor located at various depths, inhomogeneous distribution of GNP has shown different results compared with the homogeneous model. Dose enhancement can be expected with relatively deep seated tumors in radiotherapy with low energy X-rays. Inhomogeneous model is recommended for the purpose of dose enhancement study because it mimics the real distribution of GNPs in tumor.
format Online
Article
Text
id pubmed-5928303
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Journal of Biomedical Physics and Engineering
record_format MEDLINE/PubMed
spelling pubmed-59283032018-05-04 A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays Zabihzadeh, M. Moshirian, T. Ghorbani, M. Knaup, C. Behrooz, M.A. J Biomed Phys Eng Original Article BACKGROUND: To enhance the dose to tumor, the use of high atomic number elements has been proposed. OBJECTIVE: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor. METHODS: MCNP-4C Monte Carlo code was utilized for the simulation of a source, a phantom containing tumor and gold nanoparticles with concentrations of 10, 30 and 70 mg Au/g tumor. A 15 cm×15 cm×15 cm cubic water phantom was irradiated with a small planar source with four monoenergetic X-ray beams of 35, 55, 75 and 95 keV energy. Furthermore, tumor depths of 2.5 cm, 4.5 cm and 6.5 cm with homogeneous and inhomogeneous distributions of nanoparticles were studied. Each concentration, photon energy, tumor depth and type of distribution was evaluated in a separate simulation. RESULTS: Results have shown that dose enhancement factor (DEF) in tumor increases approximately linearly with the concentration of gold nanoparticles. While DEF has fluctuations with photon energy, 55 keV photons have the highest DEF values compared to other energies. While DEF has relatively the same values with tumor located at various depths, inhomogeneous distribution of GNP has shown different results compared with the homogeneous model. Dose enhancement can be expected with relatively deep seated tumors in radiotherapy with low energy X-rays. Inhomogeneous model is recommended for the purpose of dose enhancement study because it mimics the real distribution of GNPs in tumor. Journal of Biomedical Physics and Engineering 2018-03-01 /pmc/articles/PMC5928303/ /pubmed/29732337 Text en Copyright: © Journal of Biomedical Physics and Engineering http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Zabihzadeh, M.
Moshirian, T.
Ghorbani, M.
Knaup, C.
Behrooz, M.A.
A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
title A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
title_full A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
title_fullStr A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
title_full_unstemmed A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
title_short A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays
title_sort monte carlo study on dose enhancement by homogeneous and inhomogeneous distributions of gold nanoparticles in radiotherapy with low energy x-rays
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5928303/
https://www.ncbi.nlm.nih.gov/pubmed/29732337
work_keys_str_mv AT zabihzadehm amontecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT moshiriant amontecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT ghorbanim amontecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT knaupc amontecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT behroozma amontecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT zabihzadehm montecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT moshiriant montecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT ghorbanim montecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT knaupc montecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays
AT behroozma montecarlostudyondoseenhancementbyhomogeneousandinhomogeneousdistributionsofgoldnanoparticlesinradiotherapywithlowenergyxrays