Cargando…

The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study

BACKGROUND: Calcaneal fractures account for around 2% of all fractures and most of them are intra-articular fractures. Many implants have been used in the fixation of calcaneal fractures, but their biomechanical stability has not yet been well investigated. The aim of this study was to compare the p...

Descripción completa

Detalles Bibliográficos
Autores principales: Ni, Ming, Mei, Jiong, Li, Kun, Niu, Wenxin, Zhang, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5930824/
https://www.ncbi.nlm.nih.gov/pubmed/29716591
http://dx.doi.org/10.1186/s12938-018-0484-6
_version_ 1783319546713604096
author Ni, Ming
Mei, Jiong
Li, Kun
Niu, Wenxin
Zhang, Ming
author_facet Ni, Ming
Mei, Jiong
Li, Kun
Niu, Wenxin
Zhang, Ming
author_sort Ni, Ming
collection PubMed
description BACKGROUND: Calcaneal fractures account for around 2% of all fractures and most of them are intra-articular fractures. Many implants have been used in the fixation of calcaneal fractures, but their biomechanical stability has not yet been well investigated. The aim of this study was to compare the primary stability of four fixations of calcaneal fracture. METHODS: Eight cadaveric calcaneus samples were used to simulate the Sanders’ types III fracture pattern and fixed through four different implants, namely, K-wires, cannulated screws (CS), absorbable screws (AS), and plate-screw system (PSS). Each specimen was then placed into a custom-made jig and was loaded through a material testing machine to simulate the physiological condition. The primary stability was measured in the vertical direction as the stiffness and anterior–posterior direction as the calcaneocuboid force. One-way analysis of variance was used for data analysis. RESULTS: The results showed the highest stiffness of 634 (383–891; SD 226) N/mm in the intact model. It was significantly higher than the models fixed with K-wires, CS or PSS. There was no significant difference in vertical stiffness between fractures fixed with AS and the intact model or other fixed models. The intact model showed the lowest calcaneocuboid force of 153 (120–218; SD 39) N, while the fractures fixed with AS showed the greatest force of 242 (146–398; SD 84) N. The significance was only detected between these two models. CONCLUSIONS: The global stiffness was similar when the calcaneal fractures were fixed by K-wires, CS and PSS. The stability of the AS fixation differed along both the vertical and anterior–posterior directions, and was greatly influenced by the bone quality. AS for fracture fixation should be designed with greater strength and pull-out resistance.
format Online
Article
Text
id pubmed-5930824
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-59308242018-05-09 The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study Ni, Ming Mei, Jiong Li, Kun Niu, Wenxin Zhang, Ming Biomed Eng Online Research BACKGROUND: Calcaneal fractures account for around 2% of all fractures and most of them are intra-articular fractures. Many implants have been used in the fixation of calcaneal fractures, but their biomechanical stability has not yet been well investigated. The aim of this study was to compare the primary stability of four fixations of calcaneal fracture. METHODS: Eight cadaveric calcaneus samples were used to simulate the Sanders’ types III fracture pattern and fixed through four different implants, namely, K-wires, cannulated screws (CS), absorbable screws (AS), and plate-screw system (PSS). Each specimen was then placed into a custom-made jig and was loaded through a material testing machine to simulate the physiological condition. The primary stability was measured in the vertical direction as the stiffness and anterior–posterior direction as the calcaneocuboid force. One-way analysis of variance was used for data analysis. RESULTS: The results showed the highest stiffness of 634 (383–891; SD 226) N/mm in the intact model. It was significantly higher than the models fixed with K-wires, CS or PSS. There was no significant difference in vertical stiffness between fractures fixed with AS and the intact model or other fixed models. The intact model showed the lowest calcaneocuboid force of 153 (120–218; SD 39) N, while the fractures fixed with AS showed the greatest force of 242 (146–398; SD 84) N. The significance was only detected between these two models. CONCLUSIONS: The global stiffness was similar when the calcaneal fractures were fixed by K-wires, CS and PSS. The stability of the AS fixation differed along both the vertical and anterior–posterior directions, and was greatly influenced by the bone quality. AS for fracture fixation should be designed with greater strength and pull-out resistance. BioMed Central 2018-05-02 /pmc/articles/PMC5930824/ /pubmed/29716591 http://dx.doi.org/10.1186/s12938-018-0484-6 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ni, Ming
Mei, Jiong
Li, Kun
Niu, Wenxin
Zhang, Ming
The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
title The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
title_full The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
title_fullStr The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
title_full_unstemmed The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
title_short The primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
title_sort primary stability of different implants for intra-articular calcaneal fractures: an in vitro study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5930824/
https://www.ncbi.nlm.nih.gov/pubmed/29716591
http://dx.doi.org/10.1186/s12938-018-0484-6
work_keys_str_mv AT niming theprimarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT meijiong theprimarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT likun theprimarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT niuwenxin theprimarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT zhangming theprimarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT niming primarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT meijiong primarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT likun primarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT niuwenxin primarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy
AT zhangming primarystabilityofdifferentimplantsforintraarticularcalcanealfracturesaninvitrostudy