Cargando…

Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial

OBJECTIVE: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. METHODS: The initial alignment phase...

Descripción completa

Detalles Bibliográficos
Autores principales: Aydın, Burcu, Şenışık, Neslihan Ebru, Koşkan, Özgür
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5932317/
https://www.ncbi.nlm.nih.gov/pubmed/29732301
http://dx.doi.org/10.4041/kjod.2018.48.3.153
_version_ 1783319786863722496
author Aydın, Burcu
Şenışık, Neslihan Ebru
Koşkan, Özgür
author_facet Aydın, Burcu
Şenışık, Neslihan Ebru
Koşkan, Özgür
author_sort Aydın, Burcu
collection PubMed
description OBJECTIVE: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. METHODS: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi (27℃) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little's Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. RESULTS: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week × diameter × application (p < 0.05). CONCLUSIONS: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.
format Online
Article
Text
id pubmed-5932317
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Association of Orthodontists
record_format MEDLINE/PubMed
spelling pubmed-59323172018-05-05 Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial Aydın, Burcu Şenışık, Neslihan Ebru Koşkan, Özgür Korean J Orthod Original Article OBJECTIVE: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. METHODS: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi (27℃) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little's Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. RESULTS: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week × diameter × application (p < 0.05). CONCLUSIONS: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups. Korean Association of Orthodontists 2018-05 2018-04-20 /pmc/articles/PMC5932317/ /pubmed/29732301 http://dx.doi.org/10.4041/kjod.2018.48.3.153 Text en © 2018 The Korean Association of Orthodontists. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Aydın, Burcu
Şenışık, Neslihan Ebru
Koşkan, Özgür
Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial
title Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial
title_full Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial
title_fullStr Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial
title_full_unstemmed Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial
title_short Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial
title_sort evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: a single-center, randomized controlled clinical trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5932317/
https://www.ncbi.nlm.nih.gov/pubmed/29732301
http://dx.doi.org/10.4041/kjod.2018.48.3.153
work_keys_str_mv AT aydınburcu evaluationofthealignmentefficiencyofnickeltitaniumandcoppernickeltitaniumarchwiresinpatientsundergoingorthodontictreatmentovera12weekperiodasinglecenterrandomizedcontrolledclinicaltrial
AT senısıkneslihanebru evaluationofthealignmentefficiencyofnickeltitaniumandcoppernickeltitaniumarchwiresinpatientsundergoingorthodontictreatmentovera12weekperiodasinglecenterrandomizedcontrolledclinicaltrial
AT koskanozgur evaluationofthealignmentefficiencyofnickeltitaniumandcoppernickeltitaniumarchwiresinpatientsundergoingorthodontictreatmentovera12weekperiodasinglecenterrandomizedcontrolledclinicaltrial