Cargando…
Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study
BACKGROUND: Pre-specification of outcomes is an important tool to guard against outcome switching in clinical trials. However, if the outcome is not sufficiently clearly defined, then different definitions could be applied and analysed, with only the most favourable result reported. METHODS: In orde...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5932799/ https://www.ncbi.nlm.nih.gov/pubmed/29720248 http://dx.doi.org/10.1186/s13063-018-2654-z |
_version_ | 1783319871012995072 |
---|---|
author | Kahan, Brennan C. Jairath, Vipul |
author_facet | Kahan, Brennan C. Jairath, Vipul |
author_sort | Kahan, Brennan C. |
collection | PubMed |
description | BACKGROUND: Pre-specification of outcomes is an important tool to guard against outcome switching in clinical trials. However, if the outcome is not sufficiently clearly defined, then different definitions could be applied and analysed, with only the most favourable result reported. METHODS: In order to assess the impact that differing outcome definitions could have on treatment effect estimates, we re-analysed data from TRIGGER, a cluster randomised trial comparing two red blood cell transfusion strategies for patients with acute upper gastrointestinal bleeding. We varied several aspects of the definition of further bleeding: (1) the criteria for what constitutes a further bleeding episode; (2) how further bleeding is assessed; and (3) the time-point at which further bleeding is measured. RESULTS: There were marked discrepancies in the estimated odds ratios (OR) (range 0.23–0.94) and corresponding P values (range < 0.001–0.89) between different outcome definitions. At the extremes, differing outcome definitions led to markedly different conclusions; one definition led to very little evidence of a treatment effect (OR = 0.94, 95% confidence interval [CI] = 0.37–2.40, P = 0.89), while another led to very strong evidence of a treatment effect (OR = 0.23, 95% CI = 0.11–0.50, P < 0.001). CONCLUSIONS: Outcomes should be pre-specified in sufficient detail to avoid differing definitions being analysed and only the most favourable result being reported. TRIAL REGISTRATION: Clinical Trials.gov, NCT02105532. Registered on 7 April 2014. |
format | Online Article Text |
id | pubmed-5932799 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-59327992018-05-09 Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study Kahan, Brennan C. Jairath, Vipul Trials Methodology BACKGROUND: Pre-specification of outcomes is an important tool to guard against outcome switching in clinical trials. However, if the outcome is not sufficiently clearly defined, then different definitions could be applied and analysed, with only the most favourable result reported. METHODS: In order to assess the impact that differing outcome definitions could have on treatment effect estimates, we re-analysed data from TRIGGER, a cluster randomised trial comparing two red blood cell transfusion strategies for patients with acute upper gastrointestinal bleeding. We varied several aspects of the definition of further bleeding: (1) the criteria for what constitutes a further bleeding episode; (2) how further bleeding is assessed; and (3) the time-point at which further bleeding is measured. RESULTS: There were marked discrepancies in the estimated odds ratios (OR) (range 0.23–0.94) and corresponding P values (range < 0.001–0.89) between different outcome definitions. At the extremes, differing outcome definitions led to markedly different conclusions; one definition led to very little evidence of a treatment effect (OR = 0.94, 95% confidence interval [CI] = 0.37–2.40, P = 0.89), while another led to very strong evidence of a treatment effect (OR = 0.23, 95% CI = 0.11–0.50, P < 0.001). CONCLUSIONS: Outcomes should be pre-specified in sufficient detail to avoid differing definitions being analysed and only the most favourable result being reported. TRIAL REGISTRATION: Clinical Trials.gov, NCT02105532. Registered on 7 April 2014. BioMed Central 2018-05-02 /pmc/articles/PMC5932799/ /pubmed/29720248 http://dx.doi.org/10.1186/s13063-018-2654-z Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Methodology Kahan, Brennan C. Jairath, Vipul Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
title | Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
title_full | Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
title_fullStr | Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
title_full_unstemmed | Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
title_short | Outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
title_sort | outcome pre-specification requires sufficient detail to guard against outcome switching in clinical trials: a case study |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5932799/ https://www.ncbi.nlm.nih.gov/pubmed/29720248 http://dx.doi.org/10.1186/s13063-018-2654-z |
work_keys_str_mv | AT kahanbrennanc outcomeprespecificationrequiressufficientdetailtoguardagainstoutcomeswitchinginclinicaltrialsacasestudy AT jairathvipul outcomeprespecificationrequiressufficientdetailtoguardagainstoutcomeswitchinginclinicaltrialsacasestudy |