Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
AIMS: Remote haemodynamic monitoring (RHM) decreases hospitalization rates in patients with chronic heart failure (HF). Many patients with chronic HF develop pulmonary hypertension (PH) secondary to left heart disease with some acquiring combined pre‐capillary and post‐capillary PH (Cpc‐PH). The eff...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5933960/ https://www.ncbi.nlm.nih.gov/pubmed/29498245 http://dx.doi.org/10.1002/ehf2.12280 |
_version_ | 1783320033851604992 |
---|---|
author | Wolfson, Aaron M. Grazette, Luanda Saxon, Leslie Nazeer, Haider Shavelle, David M. Jermyn, Rita |
author_facet | Wolfson, Aaron M. Grazette, Luanda Saxon, Leslie Nazeer, Haider Shavelle, David M. Jermyn, Rita |
author_sort | Wolfson, Aaron M. |
collection | PubMed |
description | AIMS: Remote haemodynamic monitoring (RHM) decreases hospitalization rates in patients with chronic heart failure (HF). Many patients with chronic HF develop pulmonary hypertension (PH) secondary to left heart disease with some acquiring combined pre‐capillary and post‐capillary PH (Cpc‐PH). The efficacy of RHM in achieving pulmonary pressure reductions in patients with Cpc‐PH vs. isolated post‐capillary PH (Ipc‐PH) is unknown. The purpose of this study is to evaluate whether a higher baseline diastolic pressure gradient (DPG(baseline)) measured at the time of CardioMEMS™ HF sensor implantation is associated with lower reductions in pulmonary artery diastolic pressures (PADP). METHODS AND RESULTS: This was a retrospective analysis of 32 patients meeting clinical indications for CardioMEMS™ implantation. DPG(baseline) categorized patients as Cpc‐PH (DPG ≥ 7 mmHg) or Ipc‐PH (DPG < 7 mmHg). Minimum achievable PADP (PADP(min)) and ∆PADP (PADP(baseline) − PADP(min)) were determined. Pearson's correlation analysis and comparison of mean pressure changes were assessed. Median age was 69 years, and median left ventricular ejection fraction (LVEF) was 25%. Eight patients (25%) had a LVEF ≥40%. Twenty‐five patients (78%) met criteria for Ipc‐PH and seven (22%) for Cpc‐PH. Neither PADP(min) (ρ = 0.27; P = 0.13) nor ΔPADP (ρ = 0.07; P = 0.72) was correlated with DPG(baseline). A trend towards higher ΔPADP was seen in Cpc‐PH vs. Ipc‐PH patients (15.2 vs. 9.88 mmHg; P = 0.12). There was a moderate positive correlation between baseline PADP and ΔPADP [ρ = 0.55 (0.26–0.76); P < 0.001]. CONCLUSIONS: Decreased PADP reduction was not seen in Cpc‐PH vs. Ipc‐PH patients. Higher PADP(baseline) was associated with greater ΔPADP. Larger studies are needed to elaborate our findings. |
format | Online Article Text |
id | pubmed-5933960 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-59339602018-05-10 Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor Wolfson, Aaron M. Grazette, Luanda Saxon, Leslie Nazeer, Haider Shavelle, David M. Jermyn, Rita ESC Heart Fail Original Research Articles AIMS: Remote haemodynamic monitoring (RHM) decreases hospitalization rates in patients with chronic heart failure (HF). Many patients with chronic HF develop pulmonary hypertension (PH) secondary to left heart disease with some acquiring combined pre‐capillary and post‐capillary PH (Cpc‐PH). The efficacy of RHM in achieving pulmonary pressure reductions in patients with Cpc‐PH vs. isolated post‐capillary PH (Ipc‐PH) is unknown. The purpose of this study is to evaluate whether a higher baseline diastolic pressure gradient (DPG(baseline)) measured at the time of CardioMEMS™ HF sensor implantation is associated with lower reductions in pulmonary artery diastolic pressures (PADP). METHODS AND RESULTS: This was a retrospective analysis of 32 patients meeting clinical indications for CardioMEMS™ implantation. DPG(baseline) categorized patients as Cpc‐PH (DPG ≥ 7 mmHg) or Ipc‐PH (DPG < 7 mmHg). Minimum achievable PADP (PADP(min)) and ∆PADP (PADP(baseline) − PADP(min)) were determined. Pearson's correlation analysis and comparison of mean pressure changes were assessed. Median age was 69 years, and median left ventricular ejection fraction (LVEF) was 25%. Eight patients (25%) had a LVEF ≥40%. Twenty‐five patients (78%) met criteria for Ipc‐PH and seven (22%) for Cpc‐PH. Neither PADP(min) (ρ = 0.27; P = 0.13) nor ΔPADP (ρ = 0.07; P = 0.72) was correlated with DPG(baseline). A trend towards higher ΔPADP was seen in Cpc‐PH vs. Ipc‐PH patients (15.2 vs. 9.88 mmHg; P = 0.12). There was a moderate positive correlation between baseline PADP and ΔPADP [ρ = 0.55 (0.26–0.76); P < 0.001]. CONCLUSIONS: Decreased PADP reduction was not seen in Cpc‐PH vs. Ipc‐PH patients. Higher PADP(baseline) was associated with greater ΔPADP. Larger studies are needed to elaborate our findings. John Wiley and Sons Inc. 2018-03-02 /pmc/articles/PMC5933960/ /pubmed/29498245 http://dx.doi.org/10.1002/ehf2.12280 Text en © 2018 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Research Articles Wolfson, Aaron M. Grazette, Luanda Saxon, Leslie Nazeer, Haider Shavelle, David M. Jermyn, Rita Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor |
title | Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor |
title_full | Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor |
title_fullStr | Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor |
title_full_unstemmed | Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor |
title_short | Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor |
title_sort | baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the cardiomems™ hf sensor |
topic | Original Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5933960/ https://www.ncbi.nlm.nih.gov/pubmed/29498245 http://dx.doi.org/10.1002/ehf2.12280 |
work_keys_str_mv | AT wolfsonaaronm baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor AT grazetteluanda baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor AT saxonleslie baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor AT nazeerhaider baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor AT shavelledavidm baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor AT jermynrita baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor |