Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor

AIMS: Remote haemodynamic monitoring (RHM) decreases hospitalization rates in patients with chronic heart failure (HF). Many patients with chronic HF develop pulmonary hypertension (PH) secondary to left heart disease with some acquiring combined pre‐capillary and post‐capillary PH (Cpc‐PH). The eff...

Descripción completa

Detalles Bibliográficos
Autores principales: Wolfson, Aaron M., Grazette, Luanda, Saxon, Leslie, Nazeer, Haider, Shavelle, David M., Jermyn, Rita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5933960/
https://www.ncbi.nlm.nih.gov/pubmed/29498245
http://dx.doi.org/10.1002/ehf2.12280
_version_ 1783320033851604992
author Wolfson, Aaron M.
Grazette, Luanda
Saxon, Leslie
Nazeer, Haider
Shavelle, David M.
Jermyn, Rita
author_facet Wolfson, Aaron M.
Grazette, Luanda
Saxon, Leslie
Nazeer, Haider
Shavelle, David M.
Jermyn, Rita
author_sort Wolfson, Aaron M.
collection PubMed
description AIMS: Remote haemodynamic monitoring (RHM) decreases hospitalization rates in patients with chronic heart failure (HF). Many patients with chronic HF develop pulmonary hypertension (PH) secondary to left heart disease with some acquiring combined pre‐capillary and post‐capillary PH (Cpc‐PH). The efficacy of RHM in achieving pulmonary pressure reductions in patients with Cpc‐PH vs. isolated post‐capillary PH (Ipc‐PH) is unknown. The purpose of this study is to evaluate whether a higher baseline diastolic pressure gradient (DPG(baseline)) measured at the time of CardioMEMS™ HF sensor implantation is associated with lower reductions in pulmonary artery diastolic pressures (PADP). METHODS AND RESULTS: This was a retrospective analysis of 32 patients meeting clinical indications for CardioMEMS™ implantation. DPG(baseline) categorized patients as Cpc‐PH (DPG ≥ 7 mmHg) or Ipc‐PH (DPG < 7 mmHg). Minimum achievable PADP (PADP(min)) and ∆PADP (PADP(baseline) − PADP(min)) were determined. Pearson's correlation analysis and comparison of mean pressure changes were assessed. Median age was 69 years, and median left ventricular ejection fraction (LVEF) was 25%. Eight patients (25%) had a LVEF ≥40%. Twenty‐five patients (78%) met criteria for Ipc‐PH and seven (22%) for Cpc‐PH. Neither PADP(min) (ρ = 0.27; P = 0.13) nor ΔPADP (ρ = 0.07; P = 0.72) was correlated with DPG(baseline). A trend towards higher ΔPADP was seen in Cpc‐PH vs. Ipc‐PH patients (15.2 vs. 9.88 mmHg; P = 0.12). There was a moderate positive correlation between baseline PADP and ΔPADP [ρ = 0.55 (0.26–0.76); P < 0.001]. CONCLUSIONS: Decreased PADP reduction was not seen in Cpc‐PH vs. Ipc‐PH patients. Higher PADP(baseline) was associated with greater ΔPADP. Larger studies are needed to elaborate our findings.
format Online
Article
Text
id pubmed-5933960
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59339602018-05-10 Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor Wolfson, Aaron M. Grazette, Luanda Saxon, Leslie Nazeer, Haider Shavelle, David M. Jermyn, Rita ESC Heart Fail Original Research Articles AIMS: Remote haemodynamic monitoring (RHM) decreases hospitalization rates in patients with chronic heart failure (HF). Many patients with chronic HF develop pulmonary hypertension (PH) secondary to left heart disease with some acquiring combined pre‐capillary and post‐capillary PH (Cpc‐PH). The efficacy of RHM in achieving pulmonary pressure reductions in patients with Cpc‐PH vs. isolated post‐capillary PH (Ipc‐PH) is unknown. The purpose of this study is to evaluate whether a higher baseline diastolic pressure gradient (DPG(baseline)) measured at the time of CardioMEMS™ HF sensor implantation is associated with lower reductions in pulmonary artery diastolic pressures (PADP). METHODS AND RESULTS: This was a retrospective analysis of 32 patients meeting clinical indications for CardioMEMS™ implantation. DPG(baseline) categorized patients as Cpc‐PH (DPG ≥ 7 mmHg) or Ipc‐PH (DPG < 7 mmHg). Minimum achievable PADP (PADP(min)) and ∆PADP (PADP(baseline) − PADP(min)) were determined. Pearson's correlation analysis and comparison of mean pressure changes were assessed. Median age was 69 years, and median left ventricular ejection fraction (LVEF) was 25%. Eight patients (25%) had a LVEF ≥40%. Twenty‐five patients (78%) met criteria for Ipc‐PH and seven (22%) for Cpc‐PH. Neither PADP(min) (ρ = 0.27; P = 0.13) nor ΔPADP (ρ = 0.07; P = 0.72) was correlated with DPG(baseline). A trend towards higher ΔPADP was seen in Cpc‐PH vs. Ipc‐PH patients (15.2 vs. 9.88 mmHg; P = 0.12). There was a moderate positive correlation between baseline PADP and ΔPADP [ρ = 0.55 (0.26–0.76); P < 0.001]. CONCLUSIONS: Decreased PADP reduction was not seen in Cpc‐PH vs. Ipc‐PH patients. Higher PADP(baseline) was associated with greater ΔPADP. Larger studies are needed to elaborate our findings. John Wiley and Sons Inc. 2018-03-02 /pmc/articles/PMC5933960/ /pubmed/29498245 http://dx.doi.org/10.1002/ehf2.12280 Text en © 2018 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Research Articles
Wolfson, Aaron M.
Grazette, Luanda
Saxon, Leslie
Nazeer, Haider
Shavelle, David M.
Jermyn, Rita
Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
title Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
title_full Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
title_fullStr Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
title_full_unstemmed Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
title_short Baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the CardioMEMS™ HF sensor
title_sort baseline diastolic pressure gradient and pressure reduction in chronic heart failure patients implanted with the cardiomems™ hf sensor
topic Original Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5933960/
https://www.ncbi.nlm.nih.gov/pubmed/29498245
http://dx.doi.org/10.1002/ehf2.12280
work_keys_str_mv AT wolfsonaaronm baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor
AT grazetteluanda baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor
AT saxonleslie baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor
AT nazeerhaider baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor
AT shavelledavidm baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor
AT jermynrita baselinediastolicpressuregradientandpressurereductioninchronicheartfailurepatientsimplantedwiththecardiomemshfsensor