Cargando…
Magnetic Induction Spectroscopy for Permeability Imaging
The structural health monitoring of ferromagnetic materials is essential for controlling product quality. This paper presents the first known characterisation, utilising magnetic induction spectroscopy, of the magnetic permeability of ferromagnetic materials, a property that can facilitate such moni...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5935731/ https://www.ncbi.nlm.nih.gov/pubmed/29728584 http://dx.doi.org/10.1038/s41598-018-25507-4 |
_version_ | 1783320318715101184 |
---|---|
author | Ma, Lu Soleimani, Manuchehr |
author_facet | Ma, Lu Soleimani, Manuchehr |
author_sort | Ma, Lu |
collection | PubMed |
description | The structural health monitoring of ferromagnetic materials is essential for controlling product quality. This paper presents the first known characterisation, utilising magnetic induction spectroscopy, of the magnetic permeability of ferromagnetic materials, a property that can facilitate such monitoring. Magnetic induction coils are interrogated by a sweep of excitation frequencies in the range of 1–100 kHz, with amplitudes of induced voltages collected from both non-magnetic and ferromagnetic specimens, and their associated spectral permeability imaged. The reconstructed images show that magnetic permeability can be reconstructed using frequency difference imaging in the investigated frequency range. As such, the relative magnetic permeability of a ferromagnetic specimen can be reconstructed without needing a time difference measurement. This provides a robust imaging approach for the material characterisation of ferromagnetic specimens. |
format | Online Article Text |
id | pubmed-5935731 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-59357312018-05-10 Magnetic Induction Spectroscopy for Permeability Imaging Ma, Lu Soleimani, Manuchehr Sci Rep Article The structural health monitoring of ferromagnetic materials is essential for controlling product quality. This paper presents the first known characterisation, utilising magnetic induction spectroscopy, of the magnetic permeability of ferromagnetic materials, a property that can facilitate such monitoring. Magnetic induction coils are interrogated by a sweep of excitation frequencies in the range of 1–100 kHz, with amplitudes of induced voltages collected from both non-magnetic and ferromagnetic specimens, and their associated spectral permeability imaged. The reconstructed images show that magnetic permeability can be reconstructed using frequency difference imaging in the investigated frequency range. As such, the relative magnetic permeability of a ferromagnetic specimen can be reconstructed without needing a time difference measurement. This provides a robust imaging approach for the material characterisation of ferromagnetic specimens. Nature Publishing Group UK 2018-05-04 /pmc/articles/PMC5935731/ /pubmed/29728584 http://dx.doi.org/10.1038/s41598-018-25507-4 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Ma, Lu Soleimani, Manuchehr Magnetic Induction Spectroscopy for Permeability Imaging |
title | Magnetic Induction Spectroscopy for Permeability Imaging |
title_full | Magnetic Induction Spectroscopy for Permeability Imaging |
title_fullStr | Magnetic Induction Spectroscopy for Permeability Imaging |
title_full_unstemmed | Magnetic Induction Spectroscopy for Permeability Imaging |
title_short | Magnetic Induction Spectroscopy for Permeability Imaging |
title_sort | magnetic induction spectroscopy for permeability imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5935731/ https://www.ncbi.nlm.nih.gov/pubmed/29728584 http://dx.doi.org/10.1038/s41598-018-25507-4 |
work_keys_str_mv | AT malu magneticinductionspectroscopyforpermeabilityimaging AT soleimanimanuchehr magneticinductionspectroscopyforpermeabilityimaging |