Cargando…

Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method

The auditory stimulation method used in experiments on moth A cell(s) is generally believed to be adequate to characterize the encoding of bat echolocation signals. The stimulation method hosts, though, several biases. Their compounded effects can explain a range of discrepancies between the reporte...

Descripción completa

Detalles Bibliográficos
Autores principales: Thevenon, Herve, Pfuhl, Gerit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5936950/
https://www.ncbi.nlm.nih.gov/pubmed/29765685
http://dx.doi.org/10.1098/rsos.172404
_version_ 1783320546837004288
author Thevenon, Herve
Pfuhl, Gerit
author_facet Thevenon, Herve
Pfuhl, Gerit
author_sort Thevenon, Herve
collection PubMed
description The auditory stimulation method used in experiments on moth A cell(s) is generally believed to be adequate to characterize the encoding of bat echolocation signals. The stimulation method hosts, though, several biases. Their compounded effects can explain a range of discrepancies between the reported electrophysiological recordings and significantly alter the current interpretation. To test the hypothesis that the bias may significantly alter our current understanding of the moth's auditory transducer characteristics, papers using the same auditory stimulation method and reporting on either spiking threshold or spiking activity of the moth's A cells were analysed. The consistency of the reported data was assessed. A range of corrections issued from best practices and theoretical background were applied to the data in an attempt to re-interpret the data. We found that it is not possible to apply a posteriori corrections to all data and bias. However the corrected data indicate that the A cell's spiking may (i) be independent of the repetition rate, (ii) be maximum when detecting long and low-intensity pulses and (iii) steadily reduce as the bat closes on the moth. These observations raise the possibility that a fixed action pattern drives the moths' erratic evasive manoeuvres until the final moment. In-depth investigations of the potential bias also suggest that the auditory transducer's response may be constant for a larger frequency range than thought so far, and provide clues to explain the negative taxis in response to the searching bats' calls detection.
format Online
Article
Text
id pubmed-5936950
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Royal Society Publishing
record_format MEDLINE/PubMed
spelling pubmed-59369502018-05-15 Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method Thevenon, Herve Pfuhl, Gerit R Soc Open Sci Biology (Whole Organism) The auditory stimulation method used in experiments on moth A cell(s) is generally believed to be adequate to characterize the encoding of bat echolocation signals. The stimulation method hosts, though, several biases. Their compounded effects can explain a range of discrepancies between the reported electrophysiological recordings and significantly alter the current interpretation. To test the hypothesis that the bias may significantly alter our current understanding of the moth's auditory transducer characteristics, papers using the same auditory stimulation method and reporting on either spiking threshold or spiking activity of the moth's A cells were analysed. The consistency of the reported data was assessed. A range of corrections issued from best practices and theoretical background were applied to the data in an attempt to re-interpret the data. We found that it is not possible to apply a posteriori corrections to all data and bias. However the corrected data indicate that the A cell's spiking may (i) be independent of the repetition rate, (ii) be maximum when detecting long and low-intensity pulses and (iii) steadily reduce as the bat closes on the moth. These observations raise the possibility that a fixed action pattern drives the moths' erratic evasive manoeuvres until the final moment. In-depth investigations of the potential bias also suggest that the auditory transducer's response may be constant for a larger frequency range than thought so far, and provide clues to explain the negative taxis in response to the searching bats' calls detection. The Royal Society Publishing 2018-04-11 /pmc/articles/PMC5936950/ /pubmed/29765685 http://dx.doi.org/10.1098/rsos.172404 Text en © 2018 The Authors. http://creativecommons.org/licenses/by/4.0/ Published by the Royal Society under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, provided the original author and source are credited.
spellingShingle Biology (Whole Organism)
Thevenon, Herve
Pfuhl, Gerit
Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
title Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
title_full Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
title_fullStr Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
title_full_unstemmed Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
title_short Discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
title_sort discrepancies in the spiking threshold and frequency sensitivity of nocturnal moths explainable by biases in the canonical auditory stimulation method
topic Biology (Whole Organism)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5936950/
https://www.ncbi.nlm.nih.gov/pubmed/29765685
http://dx.doi.org/10.1098/rsos.172404
work_keys_str_mv AT thevenonherve discrepanciesinthespikingthresholdandfrequencysensitivityofnocturnalmothsexplainablebybiasesinthecanonicalauditorystimulationmethod
AT pfuhlgerit discrepanciesinthespikingthresholdandfrequencysensitivityofnocturnalmothsexplainablebybiasesinthecanonicalauditorystimulationmethod