Cargando…
Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments
The effect of altitude on typical combustible burning and related smoke detector response signals was investigated by comparison experiments at altitudes of 40 m and 3650 m based on EN54 standard tests. Point-type light scattering photoelectric smoke detectors and ionization smoke detectors were use...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5936960/ https://www.ncbi.nlm.nih.gov/pubmed/29765695 http://dx.doi.org/10.1098/rsos.180188 |
_version_ | 1783320549164843008 |
---|---|
author | Tu, Ran Zeng, Yi Fang, Jun Zhang, Yong-Ming |
author_facet | Tu, Ran Zeng, Yi Fang, Jun Zhang, Yong-Ming |
author_sort | Tu, Ran |
collection | PubMed |
description | The effect of altitude on typical combustible burning and related smoke detector response signals was investigated by comparison experiments at altitudes of 40 m and 3650 m based on EN54 standard tests. Point-type light scattering photoelectric smoke detectors and ionization smoke detectors were used for four kinds of EN54 fire tests, including two kinds of smouldering fires with wood (test fire no. 2 in EN54 standard or TF2) and cotton (TF3), and two kinds of flaming fires with polyurethane (TF4) and n-heptane (TF5). First, the influence of altitude or ambient pressure on mass loss for smouldering combustion (TF2 or TF3) was insignificant, while a significant decrease in the mass burning rate was found for flaming tests (TF4 and TF5) as reported in our previous studies. Second, for photoelectric smoke detectors in flaming fire tests, the effect of altitude was similar to that of the burning rate, whereas for the ionization smoke detectors, the response signal at high altitudes was shown to be ‘enhanced’ by the detection principle of the ionization chamber, leading to an even larger value than at normal altitude for smouldering conditions. Third, to provide a reference for smoke detector design in high-altitude areas, the differences between signal speed in rising and peak values at two locations are discussed. Also, relationship between ion chamber signals and smoke optical densities are presented by utilization of an ionization smoke detector and smoke concentration meter. Moreover, a hierarchical diagram is illustrated to provide a better understanding of the effects of altitude on combustible burning behaviour and the mechanisms of detector response. |
format | Online Article Text |
id | pubmed-5936960 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Royal Society Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-59369602018-05-15 Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments Tu, Ran Zeng, Yi Fang, Jun Zhang, Yong-Ming R Soc Open Sci Engineering The effect of altitude on typical combustible burning and related smoke detector response signals was investigated by comparison experiments at altitudes of 40 m and 3650 m based on EN54 standard tests. Point-type light scattering photoelectric smoke detectors and ionization smoke detectors were used for four kinds of EN54 fire tests, including two kinds of smouldering fires with wood (test fire no. 2 in EN54 standard or TF2) and cotton (TF3), and two kinds of flaming fires with polyurethane (TF4) and n-heptane (TF5). First, the influence of altitude or ambient pressure on mass loss for smouldering combustion (TF2 or TF3) was insignificant, while a significant decrease in the mass burning rate was found for flaming tests (TF4 and TF5) as reported in our previous studies. Second, for photoelectric smoke detectors in flaming fire tests, the effect of altitude was similar to that of the burning rate, whereas for the ionization smoke detectors, the response signal at high altitudes was shown to be ‘enhanced’ by the detection principle of the ionization chamber, leading to an even larger value than at normal altitude for smouldering conditions. Third, to provide a reference for smoke detector design in high-altitude areas, the differences between signal speed in rising and peak values at two locations are discussed. Also, relationship between ion chamber signals and smoke optical densities are presented by utilization of an ionization smoke detector and smoke concentration meter. Moreover, a hierarchical diagram is illustrated to provide a better understanding of the effects of altitude on combustible burning behaviour and the mechanisms of detector response. The Royal Society Publishing 2018-04-04 /pmc/articles/PMC5936960/ /pubmed/29765695 http://dx.doi.org/10.1098/rsos.180188 Text en © 2018 The Authors. http://creativecommons.org/licenses/by/4.0/ Published by the Royal Society under the terms of the Creative Commons Attribution License http://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, provided the original author and source are credited. |
spellingShingle | Engineering Tu, Ran Zeng, Yi Fang, Jun Zhang, Yong-Ming Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
title | Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
title_full | Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
title_fullStr | Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
title_full_unstemmed | Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
title_short | Influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
title_sort | influence of high altitude on the burning behaviour of typical combustibles and the related responses of smoke detectors in compartments |
topic | Engineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5936960/ https://www.ncbi.nlm.nih.gov/pubmed/29765695 http://dx.doi.org/10.1098/rsos.180188 |
work_keys_str_mv | AT turan influenceofhighaltitudeontheburningbehaviouroftypicalcombustiblesandtherelatedresponsesofsmokedetectorsincompartments AT zengyi influenceofhighaltitudeontheburningbehaviouroftypicalcombustiblesandtherelatedresponsesofsmokedetectorsincompartments AT fangjun influenceofhighaltitudeontheburningbehaviouroftypicalcombustiblesandtherelatedresponsesofsmokedetectorsincompartments AT zhangyongming influenceofhighaltitudeontheburningbehaviouroftypicalcombustiblesandtherelatedresponsesofsmokedetectorsincompartments |