A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study

Casting is routinely used for acute and post-operative immobilization and remains a cornerstone in the non-operative management of fractures and deformities. The application of a properly fitted and wellmolded cast, especially for a trainee, can be challenging. We present a simple method of prolongi...

Descripción completa

Detalles Bibliográficos
Autores principales: Ayzenberg, Mark, Narvaez, Michael, Raphael, James
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications, Pavia, Italy 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937361/
https://www.ncbi.nlm.nih.gov/pubmed/29770174
http://dx.doi.org/10.4081/or.2018.7314
_version_ 1783320613713084416
author Ayzenberg, Mark
Narvaez, Michael
Raphael, James
author_facet Ayzenberg, Mark
Narvaez, Michael
Raphael, James
author_sort Ayzenberg, Mark
collection PubMed
description Casting is routinely used for acute and post-operative immobilization and remains a cornerstone in the non-operative management of fractures and deformities. The application of a properly fitted and wellmolded cast, especially for a trainee, can be challenging. We present a simple method of prolonging cure time of fiberglass cast — placing ice in the dip water. Eight-ply, fiveinch fiberglass cast was circumferentially applied to an aluminum-wrapped cardboard cylinder. An electronic, 2-channel temperature sensor (TR-71wf Temp Logger, T&D Corporation, Matsumoto, Japan), accurate to 0.1ºC and accurate to ±0.3ºC, was placed between the fourth and fifth layers of fiberglass. Thirty total casts were tested using 9±1ºC (cold), 22±1ºC (ambient), and 36±1ºC (warm) dip water. Room temperature was maintained at 24±1ºC. Cast temperatures were measured during the exothermic reaction generated by the cast curing. Peak temperatures and cure times were recorded. Cure time was defined as the point of downward deflection on the timetemperature curve immediately after peak. Cure and peak temperatures were compared among groups using analysis of variance. Mean cure time was 3.5±0.1 minutes for warm water, 5.0±0.4 minutes for ambient water and 7.0±0.5 minutes for cold water. Peak temperature, measured between layers 4 and 5 of the cast material, was 36.6±0.8ºC for warm water, 31.1±1.4ºC for ambient water and 25.2±0.5ºC for cold water. Cold afforded, on average, an additional 2 minutes (40% increase) in cure time compared to ambient water and an additional 3.5 minutes (100% increase) compared to warm water. Cure time differences were significant (P<0.001) for all groups, as were peak temperature differences (P<0.001). Temperatures concerning for development of burns were never reached. Utilizing iced dip water when casting is a simple and effective method to prolong the time available for cast application. Orthopedic residents and trainees may find this useful in learning to fabricate a high quality cast. For the experienced orthopedic surgeon, this method eliminates the need to bridge longlimb casts and facilitates the application of complex casts.
format Online
Article
Text
id pubmed-5937361
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher PAGEPress Publications, Pavia, Italy
record_format MEDLINE/PubMed
spelling pubmed-59373612018-05-16 A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study Ayzenberg, Mark Narvaez, Michael Raphael, James Orthop Rev (Pavia) Article Casting is routinely used for acute and post-operative immobilization and remains a cornerstone in the non-operative management of fractures and deformities. The application of a properly fitted and wellmolded cast, especially for a trainee, can be challenging. We present a simple method of prolonging cure time of fiberglass cast — placing ice in the dip water. Eight-ply, fiveinch fiberglass cast was circumferentially applied to an aluminum-wrapped cardboard cylinder. An electronic, 2-channel temperature sensor (TR-71wf Temp Logger, T&D Corporation, Matsumoto, Japan), accurate to 0.1ºC and accurate to ±0.3ºC, was placed between the fourth and fifth layers of fiberglass. Thirty total casts were tested using 9±1ºC (cold), 22±1ºC (ambient), and 36±1ºC (warm) dip water. Room temperature was maintained at 24±1ºC. Cast temperatures were measured during the exothermic reaction generated by the cast curing. Peak temperatures and cure times were recorded. Cure time was defined as the point of downward deflection on the timetemperature curve immediately after peak. Cure and peak temperatures were compared among groups using analysis of variance. Mean cure time was 3.5±0.1 minutes for warm water, 5.0±0.4 minutes for ambient water and 7.0±0.5 minutes for cold water. Peak temperature, measured between layers 4 and 5 of the cast material, was 36.6±0.8ºC for warm water, 31.1±1.4ºC for ambient water and 25.2±0.5ºC for cold water. Cold afforded, on average, an additional 2 minutes (40% increase) in cure time compared to ambient water and an additional 3.5 minutes (100% increase) compared to warm water. Cure time differences were significant (P<0.001) for all groups, as were peak temperature differences (P<0.001). Temperatures concerning for development of burns were never reached. Utilizing iced dip water when casting is a simple and effective method to prolong the time available for cast application. Orthopedic residents and trainees may find this useful in learning to fabricate a high quality cast. For the experienced orthopedic surgeon, this method eliminates the need to bridge longlimb casts and facilitates the application of complex casts. PAGEPress Publications, Pavia, Italy 2018-03-29 /pmc/articles/PMC5937361/ /pubmed/29770174 http://dx.doi.org/10.4081/or.2018.7314 Text en ©Copyright M. Ayzenberg et al., 2018 http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Ayzenberg, Mark
Narvaez, Michael
Raphael, James
A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study
title A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study
title_full A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study
title_fullStr A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study
title_full_unstemmed A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study
title_short A simple technique to prolong molding time during application of a fiberglass cast: An in vitro study
title_sort simple technique to prolong molding time during application of a fiberglass cast: an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937361/
https://www.ncbi.nlm.nih.gov/pubmed/29770174
http://dx.doi.org/10.4081/or.2018.7314
work_keys_str_mv AT ayzenbergmark asimpletechniquetoprolongmoldingtimeduringapplicationofafiberglasscastaninvitrostudy
AT narvaezmichael asimpletechniquetoprolongmoldingtimeduringapplicationofafiberglasscastaninvitrostudy
AT raphaeljames asimpletechniquetoprolongmoldingtimeduringapplicationofafiberglasscastaninvitrostudy
AT ayzenbergmark simpletechniquetoprolongmoldingtimeduringapplicationofafiberglasscastaninvitrostudy
AT narvaezmichael simpletechniquetoprolongmoldingtimeduringapplicationofafiberglasscastaninvitrostudy
AT raphaeljames simpletechniquetoprolongmoldingtimeduringapplicationofafiberglasscastaninvitrostudy