Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model

Instrumentation failure is a common complication following complex spinal reconstruction and deformity correction. Rod fracture is the most frequent mode of hardware failure and often occurs at or near a 3-column osteotomy site. Titanium (Ti) rods are commonly utilized for spinal fixations, however,...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, Kalpit N., Walker, Gregory, Koruprolu, Sarath C., Daniels, Alan H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PAGEPress Publications, Pavia, Italy 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937366/
https://www.ncbi.nlm.nih.gov/pubmed/29770179
http://dx.doi.org/10.4081/or.2018.7541
_version_ 1783320614942015488
author Shah, Kalpit N.
Walker, Gregory
Koruprolu, Sarath C.
Daniels, Alan H.
author_facet Shah, Kalpit N.
Walker, Gregory
Koruprolu, Sarath C.
Daniels, Alan H.
author_sort Shah, Kalpit N.
collection PubMed
description Instrumentation failure is a common complication following complex spinal reconstruction and deformity correction. Rod fracture is the most frequent mode of hardware failure and often occurs at or near a 3-column osteotomy site. Titanium (Ti) rods are commonly utilized for spinal fixations, however, theoretically stiffer materials, such as cobalt-chrome (CoCr) rods are also available. Despite ongoing use in clinical practice, there is little biomechanical evidence that compares the construct ability to withstand fatigue stress for Ti and Co-Cr rods. Six models using 2 polyethylene blocks each were used to simulate a pedicle subtraction osteotomy. Within each block 6.0×45 mm polyaxial screws were placed and connected to another block using either two 6.0×100 mm Ti (3 models) or CoCr rods (3 models). The rods were bent to 40° using a French bender and were secured to the screws to give a vertical height of 1.5 cm between the blocks. The blocks were fatigue tested with 700N at 4 Hz until failure. The average number of cycles to failure for the Ti rod models was 12840 while the CoCr rod models failed at a significantly higher, 58351 cycles (P=0.003). All Ti models experienced rod fracture as the mode of failure. Two out of the three CoCr models had rod fractures while the last sample failed via screw fracture at the screw-tulip junction. The risk of rod failure is substantial in the setting of long segment spinal arthrodesis and corrective osteotomy. Efforts to increase the mechanical strength of posterior constructs may reduce the occurrence of this complication. Utilizing CoCr rods in patients with pedicle subtraction osteotomy may reduce the rate of device failure during maturation of the posterior fusion mass and limit the need for supplemental anterior column support
format Online
Article
Text
id pubmed-5937366
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher PAGEPress Publications, Pavia, Italy
record_format MEDLINE/PubMed
spelling pubmed-59373662018-05-16 Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model Shah, Kalpit N. Walker, Gregory Koruprolu, Sarath C. Daniels, Alan H. Orthop Rev (Pavia) Article Instrumentation failure is a common complication following complex spinal reconstruction and deformity correction. Rod fracture is the most frequent mode of hardware failure and often occurs at or near a 3-column osteotomy site. Titanium (Ti) rods are commonly utilized for spinal fixations, however, theoretically stiffer materials, such as cobalt-chrome (CoCr) rods are also available. Despite ongoing use in clinical practice, there is little biomechanical evidence that compares the construct ability to withstand fatigue stress for Ti and Co-Cr rods. Six models using 2 polyethylene blocks each were used to simulate a pedicle subtraction osteotomy. Within each block 6.0×45 mm polyaxial screws were placed and connected to another block using either two 6.0×100 mm Ti (3 models) or CoCr rods (3 models). The rods were bent to 40° using a French bender and were secured to the screws to give a vertical height of 1.5 cm between the blocks. The blocks were fatigue tested with 700N at 4 Hz until failure. The average number of cycles to failure for the Ti rod models was 12840 while the CoCr rod models failed at a significantly higher, 58351 cycles (P=0.003). All Ti models experienced rod fracture as the mode of failure. Two out of the three CoCr models had rod fractures while the last sample failed via screw fracture at the screw-tulip junction. The risk of rod failure is substantial in the setting of long segment spinal arthrodesis and corrective osteotomy. Efforts to increase the mechanical strength of posterior constructs may reduce the occurrence of this complication. Utilizing CoCr rods in patients with pedicle subtraction osteotomy may reduce the rate of device failure during maturation of the posterior fusion mass and limit the need for supplemental anterior column support PAGEPress Publications, Pavia, Italy 2018-03-29 /pmc/articles/PMC5937366/ /pubmed/29770179 http://dx.doi.org/10.4081/or.2018.7541 Text en ©Copyright K.N. Shah et al., 2018 http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Shah, Kalpit N.
Walker, Gregory
Koruprolu, Sarath C.
Daniels, Alan H.
Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
title Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
title_full Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
title_fullStr Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
title_full_unstemmed Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
title_short Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
title_sort biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937366/
https://www.ncbi.nlm.nih.gov/pubmed/29770179
http://dx.doi.org/10.4081/or.2018.7541
work_keys_str_mv AT shahkalpitn biomechanicalcomparisonbetweentitaniumandcobaltchromiumrodsusedinapediclesubtractionosteotomymodel
AT walkergregory biomechanicalcomparisonbetweentitaniumandcobaltchromiumrodsusedinapediclesubtractionosteotomymodel
AT koruprolusarathc biomechanicalcomparisonbetweentitaniumandcobaltchromiumrodsusedinapediclesubtractionosteotomymodel
AT danielsalanh biomechanicalcomparisonbetweentitaniumandcobaltchromiumrodsusedinapediclesubtractionosteotomymodel