Cargando…
Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients
BACKGROUND: Objective evaluation of the physical activity (PA) in patients with chronic obstructive pulmonary disease (COPD) is important. We validated a triaxial accelerometer, Active Style Pro HJA-750C® (HJA), and evaluated the necessary conditions for obtaining reproducible data. METHODS: The PA...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937578/ https://www.ncbi.nlm.nih.gov/pubmed/29849834 http://dx.doi.org/10.1155/2018/8343705 |
_version_ | 1783320649658269696 |
---|---|
author | Miyamoto, Seiko Minakata, Yoshiaki Azuma, Yuichiro Kawabe, Kazumi Ono, Hideya Yanagimoto, Ryuta Suruda, Tadatoshi |
author_facet | Miyamoto, Seiko Minakata, Yoshiaki Azuma, Yuichiro Kawabe, Kazumi Ono, Hideya Yanagimoto, Ryuta Suruda, Tadatoshi |
author_sort | Miyamoto, Seiko |
collection | PubMed |
description | BACKGROUND: Objective evaluation of the physical activity (PA) in patients with chronic obstructive pulmonary disease (COPD) is important. We validated a triaxial accelerometer, Active Style Pro HJA-750C® (HJA), and evaluated the necessary conditions for obtaining reproducible data. METHODS: The PA measured by HJA was compared with that measured by two already validated accelerometers in 11 patients with COPD (age: 76.6 ± 6.9, FEV1% predicted: 57.6 ± 18.6). Then, the influence of weather and holidays on the PA and the required number of days to obtain repeatability were examined in 21 patients with COPD (age: 73.0 ± 8.0, FEV1% predicted: 58.7 ± 19.0). RESULTS: The PA values measured by HJA and those by DynaPort Move Monitor® (DMM) or Actimarker® (AM) were significantly correlated at all intensities (p=0.024 at ≥4.0 METs by DMM and p < 0.0001 at the rest) except at ≥4.0 METs by AM, though the values measured by HJA were higher than those by AM which was reported to underestimate PA. The durations of PA on rainy days were significantly shorter than those on nonrainy days, but those on holidays were not different from those on weekdays. The values of ICC for 3, 4, or 5 days were higher than 0.8 at all intensities. The PA measured by HJA was correlated with the dyspnea scale FVC and age and tended to correlate with FEV1. CONCLUSIONS: The HJA was validated for evaluating the PA in patients with COPD. This trial is registered with UMIN000016363. |
format | Online Article Text |
id | pubmed-5937578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-59375782018-05-30 Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients Miyamoto, Seiko Minakata, Yoshiaki Azuma, Yuichiro Kawabe, Kazumi Ono, Hideya Yanagimoto, Ryuta Suruda, Tadatoshi Can Respir J Research Article BACKGROUND: Objective evaluation of the physical activity (PA) in patients with chronic obstructive pulmonary disease (COPD) is important. We validated a triaxial accelerometer, Active Style Pro HJA-750C® (HJA), and evaluated the necessary conditions for obtaining reproducible data. METHODS: The PA measured by HJA was compared with that measured by two already validated accelerometers in 11 patients with COPD (age: 76.6 ± 6.9, FEV1% predicted: 57.6 ± 18.6). Then, the influence of weather and holidays on the PA and the required number of days to obtain repeatability were examined in 21 patients with COPD (age: 73.0 ± 8.0, FEV1% predicted: 58.7 ± 19.0). RESULTS: The PA values measured by HJA and those by DynaPort Move Monitor® (DMM) or Actimarker® (AM) were significantly correlated at all intensities (p=0.024 at ≥4.0 METs by DMM and p < 0.0001 at the rest) except at ≥4.0 METs by AM, though the values measured by HJA were higher than those by AM which was reported to underestimate PA. The durations of PA on rainy days were significantly shorter than those on nonrainy days, but those on holidays were not different from those on weekdays. The values of ICC for 3, 4, or 5 days were higher than 0.8 at all intensities. The PA measured by HJA was correlated with the dyspnea scale FVC and age and tended to correlate with FEV1. CONCLUSIONS: The HJA was validated for evaluating the PA in patients with COPD. This trial is registered with UMIN000016363. Hindawi 2018-04-23 /pmc/articles/PMC5937578/ /pubmed/29849834 http://dx.doi.org/10.1155/2018/8343705 Text en Copyright © 2018 Seiko Miyamoto et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Miyamoto, Seiko Minakata, Yoshiaki Azuma, Yuichiro Kawabe, Kazumi Ono, Hideya Yanagimoto, Ryuta Suruda, Tadatoshi Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients |
title | Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients |
title_full | Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients |
title_fullStr | Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients |
title_full_unstemmed | Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients |
title_short | Verification of a Motion Sensor for Evaluating Physical Activity in COPD Patients |
title_sort | verification of a motion sensor for evaluating physical activity in copd patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937578/ https://www.ncbi.nlm.nih.gov/pubmed/29849834 http://dx.doi.org/10.1155/2018/8343705 |
work_keys_str_mv | AT miyamotoseiko verificationofamotionsensorforevaluatingphysicalactivityincopdpatients AT minakatayoshiaki verificationofamotionsensorforevaluatingphysicalactivityincopdpatients AT azumayuichiro verificationofamotionsensorforevaluatingphysicalactivityincopdpatients AT kawabekazumi verificationofamotionsensorforevaluatingphysicalactivityincopdpatients AT onohideya verificationofamotionsensorforevaluatingphysicalactivityincopdpatients AT yanagimotoryuta verificationofamotionsensorforevaluatingphysicalactivityincopdpatients AT surudatadatoshi verificationofamotionsensorforevaluatingphysicalactivityincopdpatients |