Haemodynamic outcomes during piston-based mechanical CPR with or without active decompression in a porcine model of cardiac arrest
BACKGROUND: Experimental active compression-decompression (ACD) CPR is associated with increased haemodynamic outcomes compared to standard mechanical chest compressions. Since no clinically available mechanical chest compression device is capable of ACD-CPR, we modified the LUCAS 2 (Physio-Control,...
Autores principales: | Steinberg, Mikkel T., Olsen, Jan-Aage, Eriksen, Morten, Neset, Andres, Norseng, Per Andreas, Kramer-Johansen, Jo, Hardig, Bjarne Madsen, Wik, Lars |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937838/ https://www.ncbi.nlm.nih.gov/pubmed/29690910 http://dx.doi.org/10.1186/s13049-018-0496-z |
Ejemplares similares
-
Chest wall mechanics during mechanical chest compression and its relationship to CPR-related injuries and survival
por: Azeli, Youcef, et al.
Publicado: (2022) -
Closed-loop machine-controlled CPR system optimises haemodynamics during prolonged CPR
por: Sebastian, Pierre S., et al.
Publicado: (2020) -
Effect of IV amiodarone on CPR haemodynamics and outcome: experimental study in dogs
por: Paiva, EF, et al.
Publicado: (2002) -
Evaluation of coronary blood flow velocity during cardiac arrest with circulation maintained through mechanical chest compressions in a porcine model
por: Wagner, Henrik, et al.
Publicado: (2011) -
piston of BEBC