Cargando…

Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study

PURPOSE: Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept stud...

Descripción completa

Detalles Bibliográficos
Autores principales: Clay, L., Stark, B., Gunnarsson, U., Strigård, K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937886/
https://www.ncbi.nlm.nih.gov/pubmed/29247365
http://dx.doi.org/10.1007/s10029-017-1712-x
_version_ 1783320700083240960
author Clay, L.
Stark, B.
Gunnarsson, U.
Strigård, K.
author_facet Clay, L.
Stark, B.
Gunnarsson, U.
Strigård, K.
author_sort Clay, L.
collection PubMed
description PURPOSE: Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept study, with satisfactory results. In this multicenter randomized study, the use of skin graft was compared to synthetic mesh in giant ventral hernia repair. METHODS: Non-smoking patients with a ventral hernia > 10 cm wide were randomized to repair using an on-lay autologous full-thickness skin graft or a synthetic mesh. The primary endpoint was surgical site complications during the first 3 months. A secondary endpoint was patient comfort. Fifty-three patients were included. Clinical evaluation was performed at a 3-month follow-up appointment. RESULTS: There were fewer patients in the skin graft group reporting discomfort: 3 (13%) vs. 12 (43%) (p = 0.016). Skin graft patients had less pain and a better general improvement. No difference was seen regarding seroma; 13 (54%) vs. 13 (46%), or subcutaneous wound infection; 5 (20%) vs. 7 (25%). One recurrence appeared in each group. Three patients in the skin graft group and two in the synthetic mesh group were admitted to the intensive care unit. CONCLUSION: No difference was seen for the primary endpoint short-term surgical complication. Full-thickness skin graft appears to be a reliable material for ventral hernia repair producing no more complications than when using synthetic mesh. Patients repaired with a skin graft have less subjective abdominal wall symptoms.
format Online
Article
Text
id pubmed-5937886
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-59378862018-05-11 Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study Clay, L. Stark, B. Gunnarsson, U. Strigård, K. Hernia Original Article PURPOSE: Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept study, with satisfactory results. In this multicenter randomized study, the use of skin graft was compared to synthetic mesh in giant ventral hernia repair. METHODS: Non-smoking patients with a ventral hernia > 10 cm wide were randomized to repair using an on-lay autologous full-thickness skin graft or a synthetic mesh. The primary endpoint was surgical site complications during the first 3 months. A secondary endpoint was patient comfort. Fifty-three patients were included. Clinical evaluation was performed at a 3-month follow-up appointment. RESULTS: There were fewer patients in the skin graft group reporting discomfort: 3 (13%) vs. 12 (43%) (p = 0.016). Skin graft patients had less pain and a better general improvement. No difference was seen regarding seroma; 13 (54%) vs. 13 (46%), or subcutaneous wound infection; 5 (20%) vs. 7 (25%). One recurrence appeared in each group. Three patients in the skin graft group and two in the synthetic mesh group were admitted to the intensive care unit. CONCLUSION: No difference was seen for the primary endpoint short-term surgical complication. Full-thickness skin graft appears to be a reliable material for ventral hernia repair producing no more complications than when using synthetic mesh. Patients repaired with a skin graft have less subjective abdominal wall symptoms. Springer Paris 2017-12-15 2018 /pmc/articles/PMC5937886/ /pubmed/29247365 http://dx.doi.org/10.1007/s10029-017-1712-x Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Clay, L.
Stark, B.
Gunnarsson, U.
Strigård, K.
Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
title Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
title_full Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
title_fullStr Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
title_full_unstemmed Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
title_short Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
title_sort full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937886/
https://www.ncbi.nlm.nih.gov/pubmed/29247365
http://dx.doi.org/10.1007/s10029-017-1712-x
work_keys_str_mv AT clayl fullthicknessskingraftvssyntheticmeshintherepairofgiantincisionalherniaarandomizedcontrolledmulticenterstudy
AT starkb fullthicknessskingraftvssyntheticmeshintherepairofgiantincisionalherniaarandomizedcontrolledmulticenterstudy
AT gunnarssonu fullthicknessskingraftvssyntheticmeshintherepairofgiantincisionalherniaarandomizedcontrolledmulticenterstudy
AT strigardk fullthicknessskingraftvssyntheticmeshintherepairofgiantincisionalherniaarandomizedcontrolledmulticenterstudy