Cargando…
Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study
BACKGROUND: Various factors like implant angulation, type of impression material and tray type affects the implant impression accuracy. To date limited in-vitro studies were carried out on the implant impression accuracy of unilateral partially edentulous arches. The aim of this research was to eval...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937963/ https://www.ncbi.nlm.nih.gov/pubmed/29750102 http://dx.doi.org/10.4317/jced.54726 |
_version_ | 1783320711878672384 |
---|---|
author | Parameshwari, G. Chittaranjan, B. Sudhir, N. Anulekha-Avinash, C.-K. Taruna, M. Ramureddy, M. |
author_facet | Parameshwari, G. Chittaranjan, B. Sudhir, N. Anulekha-Avinash, C.-K. Taruna, M. Ramureddy, M. |
author_sort | Parameshwari, G. |
collection | PubMed |
description | BACKGROUND: Various factors like implant angulation, type of impression material and tray type affects the implant impression accuracy. To date limited in-vitro studies were carried out on the implant impression accuracy of unilateral partially edentulous arches. The aim of this research was to evaluate the effects of 0o, 15o and 25o implant angulations on impression accuracy in simulated master casts of unilateral partially edentulous situation using different impression materials and tray selections. MATERIAL AND METHODS: 30 replicas (N = 30) of a resin matrix (control) containing four implant analogues placed unilaterally from the midline till the region of second molar at an angulation of 00, 00, 150 and 250 to the vertical axis of the ridge respectively were obtained by using three impression techniques (stock metal tray, closed custom tray, and open nonsplinted custom tray) and two different impression materials (Polyvinyl-siloxane and polyether). Specific dimensions of the resultant casts were measured using coordinated measuring microscope. Mean linear changes were calculated and statistically analyzed using analysis of variance (ANOVA) and Tukey’s post-hoc procedures (p< 0.05). RESULTS: The casts obtained from all three impression techniques had significant differences in dimensions (p<0.05) as compared to that of master model irrespective of impression materials. Comparing the techniques with regard to the parallel implants, no statistical significant difference (p<0.05) was observed with custom tray techniques (closed/open). Whereas while comparing parallel versus non parallel, open tray technique showed superior accuracy compared to closed tray technique as the angulation increased more than 15 degrees. CONCLUSIONS: The influence of material and technique appeared to be significant for highly non axial implant angulations (p< 0.05), and increased angulation tended to decrease impression accuracy. The open tray technique was more accurate with highly nonaxially oriented implants for the small sample size investigated. Key words:Implant impressions, partially edentulous arch, angulated implants. |
format | Online Article Text |
id | pubmed-5937963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-59379632018-05-10 Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study Parameshwari, G. Chittaranjan, B. Sudhir, N. Anulekha-Avinash, C.-K. Taruna, M. Ramureddy, M. J Clin Exp Dent Research BACKGROUND: Various factors like implant angulation, type of impression material and tray type affects the implant impression accuracy. To date limited in-vitro studies were carried out on the implant impression accuracy of unilateral partially edentulous arches. The aim of this research was to evaluate the effects of 0o, 15o and 25o implant angulations on impression accuracy in simulated master casts of unilateral partially edentulous situation using different impression materials and tray selections. MATERIAL AND METHODS: 30 replicas (N = 30) of a resin matrix (control) containing four implant analogues placed unilaterally from the midline till the region of second molar at an angulation of 00, 00, 150 and 250 to the vertical axis of the ridge respectively were obtained by using three impression techniques (stock metal tray, closed custom tray, and open nonsplinted custom tray) and two different impression materials (Polyvinyl-siloxane and polyether). Specific dimensions of the resultant casts were measured using coordinated measuring microscope. Mean linear changes were calculated and statistically analyzed using analysis of variance (ANOVA) and Tukey’s post-hoc procedures (p< 0.05). RESULTS: The casts obtained from all three impression techniques had significant differences in dimensions (p<0.05) as compared to that of master model irrespective of impression materials. Comparing the techniques with regard to the parallel implants, no statistical significant difference (p<0.05) was observed with custom tray techniques (closed/open). Whereas while comparing parallel versus non parallel, open tray technique showed superior accuracy compared to closed tray technique as the angulation increased more than 15 degrees. CONCLUSIONS: The influence of material and technique appeared to be significant for highly non axial implant angulations (p< 0.05), and increased angulation tended to decrease impression accuracy. The open tray technique was more accurate with highly nonaxially oriented implants for the small sample size investigated. Key words:Implant impressions, partially edentulous arch, angulated implants. Medicina Oral S.L. 2018-04-01 /pmc/articles/PMC5937963/ /pubmed/29750102 http://dx.doi.org/10.4317/jced.54726 Text en Copyright: © 2018 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Parameshwari, G. Chittaranjan, B. Sudhir, N. Anulekha-Avinash, C.-K. Taruna, M. Ramureddy, M. Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study |
title | Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study |
title_full | Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study |
title_fullStr | Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study |
title_full_unstemmed | Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study |
title_short | Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- An in vitro study |
title_sort | evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially edentulous mandible- an in vitro study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5937963/ https://www.ncbi.nlm.nih.gov/pubmed/29750102 http://dx.doi.org/10.4317/jced.54726 |
work_keys_str_mv | AT parameshwarig evaluationofaccuracyofvariousimpressiontechniquesandimpressionmaterialsinrecordingmultipleimplantsplacedunilaterallyinapartiallyedentulousmandibleaninvitrostudy AT chittaranjanb evaluationofaccuracyofvariousimpressiontechniquesandimpressionmaterialsinrecordingmultipleimplantsplacedunilaterallyinapartiallyedentulousmandibleaninvitrostudy AT sudhirn evaluationofaccuracyofvariousimpressiontechniquesandimpressionmaterialsinrecordingmultipleimplantsplacedunilaterallyinapartiallyedentulousmandibleaninvitrostudy AT anulekhaavinashck evaluationofaccuracyofvariousimpressiontechniquesandimpressionmaterialsinrecordingmultipleimplantsplacedunilaterallyinapartiallyedentulousmandibleaninvitrostudy AT tarunam evaluationofaccuracyofvariousimpressiontechniquesandimpressionmaterialsinrecordingmultipleimplantsplacedunilaterallyinapartiallyedentulousmandibleaninvitrostudy AT ramureddym evaluationofaccuracyofvariousimpressiontechniquesandimpressionmaterialsinrecordingmultipleimplantsplacedunilaterallyinapartiallyedentulousmandibleaninvitrostudy |