Cargando…

Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water

BACKGROUND: Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irrever...

Descripción completa

Detalles Bibliográficos
Autores principales: Savabi, Omid, Nejatidanesh, Farahnaz, Bagheri, Kamran Poshang, Karimi, Leila, Savabi, Ghazal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5938899/
https://www.ncbi.nlm.nih.gov/pubmed/29770172
http://dx.doi.org/10.4103/ijpvm.IJPVM_143_16
_version_ 1783320869794217984
author Savabi, Omid
Nejatidanesh, Farahnaz
Bagheri, Kamran Poshang
Karimi, Leila
Savabi, Ghazal
author_facet Savabi, Omid
Nejatidanesh, Farahnaz
Bagheri, Kamran Poshang
Karimi, Leila
Savabi, Ghazal
author_sort Savabi, Omid
collection PubMed
description BACKGROUND: Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irreversible hydrocolloid impression materials and preventing cross-contamination. METHODS: Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples (n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05). RESULTS: The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa, S. aureus, and C. albicans, respectively) (P < 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only (P < 0.001) although they did not vanish microorganisms completely. CONCLUSIONS: Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission.
format Online
Article
Text
id pubmed-5938899
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-59388992018-05-16 Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water Savabi, Omid Nejatidanesh, Farahnaz Bagheri, Kamran Poshang Karimi, Leila Savabi, Ghazal Int J Prev Med Original Article BACKGROUND: Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irreversible hydrocolloid impression materials and preventing cross-contamination. METHODS: Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples (n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05). RESULTS: The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa, S. aureus, and C. albicans, respectively) (P < 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only (P < 0.001) although they did not vanish microorganisms completely. CONCLUSIONS: Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission. Medknow Publications & Media Pvt Ltd 2018-04-11 /pmc/articles/PMC5938899/ /pubmed/29770172 http://dx.doi.org/10.4103/ijpvm.IJPVM_143_16 Text en Copyright: © 2018 International Journal of Preventive Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Savabi, Omid
Nejatidanesh, Farahnaz
Bagheri, Kamran Poshang
Karimi, Leila
Savabi, Ghazal
Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
title Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
title_full Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
title_fullStr Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
title_full_unstemmed Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
title_short Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
title_sort prevention of cross-contamination risk by disinfection of irreversible hydrocolloid impression materials with ozonated water
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5938899/
https://www.ncbi.nlm.nih.gov/pubmed/29770172
http://dx.doi.org/10.4103/ijpvm.IJPVM_143_16
work_keys_str_mv AT savabiomid preventionofcrosscontaminationriskbydisinfectionofirreversiblehydrocolloidimpressionmaterialswithozonatedwater
AT nejatidaneshfarahnaz preventionofcrosscontaminationriskbydisinfectionofirreversiblehydrocolloidimpressionmaterialswithozonatedwater
AT bagherikamranposhang preventionofcrosscontaminationriskbydisinfectionofirreversiblehydrocolloidimpressionmaterialswithozonatedwater
AT karimileila preventionofcrosscontaminationriskbydisinfectionofirreversiblehydrocolloidimpressionmaterialswithozonatedwater
AT savabighazal preventionofcrosscontaminationriskbydisinfectionofirreversiblehydrocolloidimpressionmaterialswithozonatedwater