Cargando…

Longitudinal analysis of cardiac structure and function in incident-automated peritoneal dialysis: comparison between icodextrin solution and glucose-based solution

BACKGROUND: This study aimed to evaluate the longitudinal changes in cardiac structure and function in incident-automated peritoneal dialysis (APD) patients. METHODS: We conducted a 2-year prospective, randomized, open-label, parallel-group study to compare the efficacy of icodextrin solution versus...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jin-Bor, Cheng, Ben-Chung, Liu, Wen-Hao, Liao, Shang-Chih, Fu, Mao-Young Morgan, Moi, Sin-Hua, Yang, Cheng-Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5941563/
https://www.ncbi.nlm.nih.gov/pubmed/29739354
http://dx.doi.org/10.1186/s12882-018-0912-7
Descripción
Sumario:BACKGROUND: This study aimed to evaluate the longitudinal changes in cardiac structure and function in incident-automated peritoneal dialysis (APD) patients. METHODS: We conducted a 2-year prospective, randomized, open-label, parallel-group study to compare the efficacy of icodextrin solution versus glucose-based solution. Echocardiography was performed at baseline, 1 and 2 years. Echocardiographic parameters over 2 years were evaluated for each group, using the Friedman test. Generalized linear regression analysis was used to test the associations between baseline clinical variables and echocardiographic changes, and a multivariate model was used to analyze cardiac function between the two groups. RESULTS: A total of 43 APD patients were enrolled in the beginning of this study. Twenty patients in the icodextrin group (ICO) and 18 patients in the glucose group (GLU) completed the study. In left ventricular (LV) systolic function measurements, ejection fraction (EF) increased significantly in the GLU group. Measurements of LV diastolic function and septal early mitral annulus velocity (EMV) increased significantly from baseline to 24-months in the ICO group (5.43–5.51 ms). The GLU group showed a significant decrease in peak early diastolic velocity (EDV) (70.67–68.25 cm/s), but a significant increase in septal EMV (5.94–7.57 ms) from baseline to 24-months. No significant association was found between the baseline clinical variables and echocardiographic changes within 24 months in the generalized linear regression analysis. Multivariate models were used to investigate changes in the four primary endpoints, namely, myocardial performance index (MPI), left ventricular ejection fraction (LVEF), deceleration time (DT), and E/e′ ratio. These primary endpoints show no significant association with the baseline values in both the ICO and GLU groups. CONCLUSION: The present study demonstrates that long-dwell icodextrin solution can maintain reasonable cardiac structure and function in incident-APD patients. TRIAL REGISTRATION: ISRCTN14931270 (retrospectively registered on 23/03/2018).