Cargando…
Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects
BACKGROUND: Preterm birth is a major public health problem in developed countries. In this context, we have conducted research into outpatient monitoring of uterine electrical activity in women at risk of preterm delivery. The objective of this preliminary study was to perform automated detection of...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5941683/ https://www.ncbi.nlm.nih.gov/pubmed/29739438 http://dx.doi.org/10.1186/s12884-018-1778-1 |
_version_ | 1783321335392370688 |
---|---|
author | Muszynski, C. Happillon, T. Azudin, K. Tylcz, J.-B. Istrate, D. Marque, C. |
author_facet | Muszynski, C. Happillon, T. Azudin, K. Tylcz, J.-B. Istrate, D. Marque, C. |
author_sort | Muszynski, C. |
collection | PubMed |
description | BACKGROUND: Preterm birth is a major public health problem in developed countries. In this context, we have conducted research into outpatient monitoring of uterine electrical activity in women at risk of preterm delivery. The objective of this preliminary study was to perform automated detection of uterine contractions (without human intervention or tocographic signal, TOCO) by processing the EHG recorded on the abdomen of pregnant women. The feasibility and accuracy of uterine contraction detection based on EHG processing were tested and compared to expert decision using external tocodynamometry (TOCO) . METHODS: The study protocol was approved by local Ethics Committees under numbers ID-RCB 2016-A00663-48 for France and VSN 02-0006-V2 for Iceland. Two populations of women were included (threatened preterm birth and labour) in order to test our system of recognition of the various types of uterine contractions. EHG signal acquisition was performed according to a standardized protocol to ensure optimal reproducibility of EHG recordings. A system of 18 Ag/AgCl surface electrodes was used by placing 16 recording electrodes between the woman’s pubis and umbilicus according to a 4 × 4 matrix. TOCO was recorded simultaneously with EHG recording. EHG signals were analysed in real-time by calculation of the nonlinear correlation coefficient H(2). A curve representing the number of correlated pairs of signals according to the value of H(2) calculated between bipolar signals was then plotted. High values of H(2) indicated the presence of an event that may correspond to a contraction. Two tests were performed after detection of an event (fusion and elimination of certain events) in order to increase the contraction detection rate. RESULTS: The EHG database contained 51 recordings from pregnant women, with a total of 501 contractions previously labelled by analysis of the corresponding tocographic recording. The percentage recognitions obtained by application of the method based on coefficient H(2) was 100% with 782% of false alarms. Addition of fusion and elimination tests to the previously obtained detections allowed the false alarm rate to be divided by 8.5, while maintaining an excellent detection rate (96%). CONCLUSION: These preliminary results appear to be encouraging for monitoring of uterine contractions by algorithm-based automated detection to process the electrohysterographic signal (EHG). This compact recording system, based on the use of surface electrodes attached to the skin, appears to be particularly suitable for outpatient monitoring of uterine contractions, possibly at home, allowing telemonitoring of pregnancies. One of the advantages of EHG processing is that useful information concerning contraction efficiency can be extracted from this signal, which is not possible with the TOCO signal. |
format | Online Article Text |
id | pubmed-5941683 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-59416832018-05-14 Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects Muszynski, C. Happillon, T. Azudin, K. Tylcz, J.-B. Istrate, D. Marque, C. BMC Pregnancy Childbirth Research Article BACKGROUND: Preterm birth is a major public health problem in developed countries. In this context, we have conducted research into outpatient monitoring of uterine electrical activity in women at risk of preterm delivery. The objective of this preliminary study was to perform automated detection of uterine contractions (without human intervention or tocographic signal, TOCO) by processing the EHG recorded on the abdomen of pregnant women. The feasibility and accuracy of uterine contraction detection based on EHG processing were tested and compared to expert decision using external tocodynamometry (TOCO) . METHODS: The study protocol was approved by local Ethics Committees under numbers ID-RCB 2016-A00663-48 for France and VSN 02-0006-V2 for Iceland. Two populations of women were included (threatened preterm birth and labour) in order to test our system of recognition of the various types of uterine contractions. EHG signal acquisition was performed according to a standardized protocol to ensure optimal reproducibility of EHG recordings. A system of 18 Ag/AgCl surface electrodes was used by placing 16 recording electrodes between the woman’s pubis and umbilicus according to a 4 × 4 matrix. TOCO was recorded simultaneously with EHG recording. EHG signals were analysed in real-time by calculation of the nonlinear correlation coefficient H(2). A curve representing the number of correlated pairs of signals according to the value of H(2) calculated between bipolar signals was then plotted. High values of H(2) indicated the presence of an event that may correspond to a contraction. Two tests were performed after detection of an event (fusion and elimination of certain events) in order to increase the contraction detection rate. RESULTS: The EHG database contained 51 recordings from pregnant women, with a total of 501 contractions previously labelled by analysis of the corresponding tocographic recording. The percentage recognitions obtained by application of the method based on coefficient H(2) was 100% with 782% of false alarms. Addition of fusion and elimination tests to the previously obtained detections allowed the false alarm rate to be divided by 8.5, while maintaining an excellent detection rate (96%). CONCLUSION: These preliminary results appear to be encouraging for monitoring of uterine contractions by algorithm-based automated detection to process the electrohysterographic signal (EHG). This compact recording system, based on the use of surface electrodes attached to the skin, appears to be particularly suitable for outpatient monitoring of uterine contractions, possibly at home, allowing telemonitoring of pregnancies. One of the advantages of EHG processing is that useful information concerning contraction efficiency can be extracted from this signal, which is not possible with the TOCO signal. BioMed Central 2018-05-08 /pmc/articles/PMC5941683/ /pubmed/29739438 http://dx.doi.org/10.1186/s12884-018-1778-1 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Muszynski, C. Happillon, T. Azudin, K. Tylcz, J.-B. Istrate, D. Marque, C. Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
title | Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
title_full | Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
title_fullStr | Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
title_full_unstemmed | Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
title_short | Automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
title_sort | automated electrohysterographic detection of uterine contractions for monitoring of pregnancy: feasibility and prospects |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5941683/ https://www.ncbi.nlm.nih.gov/pubmed/29739438 http://dx.doi.org/10.1186/s12884-018-1778-1 |
work_keys_str_mv | AT muszynskic automatedelectrohysterographicdetectionofuterinecontractionsformonitoringofpregnancyfeasibilityandprospects AT happillont automatedelectrohysterographicdetectionofuterinecontractionsformonitoringofpregnancyfeasibilityandprospects AT azudink automatedelectrohysterographicdetectionofuterinecontractionsformonitoringofpregnancyfeasibilityandprospects AT tylczjb automatedelectrohysterographicdetectionofuterinecontractionsformonitoringofpregnancyfeasibilityandprospects AT istrated automatedelectrohysterographicdetectionofuterinecontractionsformonitoringofpregnancyfeasibilityandprospects AT marquec automatedelectrohysterographicdetectionofuterinecontractionsformonitoringofpregnancyfeasibilityandprospects |