Cargando…

Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces

[Image: see text] Models for bacterial adhesion to substratum surfaces all include uncertainty with respect to the (ir)reversibility of adhesion. In a model, based on vibrations exhibited by adhering bacteria parallel to a surface, adhesion was described as a result of reversible binding of multiple...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Westen, Rebecca, Sjollema, Jelmer, Molenaar, Robert, Sharma, Prashant K., van der Mei, Henny C., Busscher, Henk J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5942874/
https://www.ncbi.nlm.nih.gov/pubmed/29649869
http://dx.doi.org/10.1021/acs.langmuir.7b04331
_version_ 1783321535391465472
author van der Westen, Rebecca
Sjollema, Jelmer
Molenaar, Robert
Sharma, Prashant K.
van der Mei, Henny C.
Busscher, Henk J.
author_facet van der Westen, Rebecca
Sjollema, Jelmer
Molenaar, Robert
Sharma, Prashant K.
van der Mei, Henny C.
Busscher, Henk J.
author_sort van der Westen, Rebecca
collection PubMed
description [Image: see text] Models for bacterial adhesion to substratum surfaces all include uncertainty with respect to the (ir)reversibility of adhesion. In a model, based on vibrations exhibited by adhering bacteria parallel to a surface, adhesion was described as a result of reversible binding of multiple bacterial tethers that detach from and successively reattach to a surface, eventually making bacterial adhesion irreversible. Here, we use total internal reflection microscopy to determine whether adhering bacteria also exhibit variations over time in their perpendicular distance above surfaces. Streptococci with fibrillar surface tethers showed perpendicular vibrations with amplitudes of around 5 nm, regardless of surface hydrophobicity. Adhering, nonfibrillated streptococci vibrated with amplitudes around 20 nm above a hydrophobic surface. Amplitudes did not depend on ionic strength for either strain. Calculations of bacterial energies from their distances above the surfaces using the Boltzman equation showed that bacteria with fibrillar tethers vibrated as a harmonic oscillator. The energy of bacteria without fibrillar tethers varied with distance in a comparable fashion as the DLVO (Derjaguin, Landau, Verwey, and Overbeek)-interaction energy. Distance variations above the surface over time of bacteria with fibrillar tethers are suggested to be governed by the harmonic oscillations, allowed by elasticity of the tethers, piercing through the potential energy barrier. Bacteria without fibrillar tethers “float” above a surface in the secondary energy minimum, with their perpendicular displacement restricted by their thermal energy and the width of the secondary minimum. The distinction between “tether-coupled” and “floating” adhesion is new, and may have implications for bacterial detachment strategies.
format Online
Article
Text
id pubmed-5942874
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-59428742018-05-10 Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces van der Westen, Rebecca Sjollema, Jelmer Molenaar, Robert Sharma, Prashant K. van der Mei, Henny C. Busscher, Henk J. Langmuir [Image: see text] Models for bacterial adhesion to substratum surfaces all include uncertainty with respect to the (ir)reversibility of adhesion. In a model, based on vibrations exhibited by adhering bacteria parallel to a surface, adhesion was described as a result of reversible binding of multiple bacterial tethers that detach from and successively reattach to a surface, eventually making bacterial adhesion irreversible. Here, we use total internal reflection microscopy to determine whether adhering bacteria also exhibit variations over time in their perpendicular distance above surfaces. Streptococci with fibrillar surface tethers showed perpendicular vibrations with amplitudes of around 5 nm, regardless of surface hydrophobicity. Adhering, nonfibrillated streptococci vibrated with amplitudes around 20 nm above a hydrophobic surface. Amplitudes did not depend on ionic strength for either strain. Calculations of bacterial energies from their distances above the surfaces using the Boltzman equation showed that bacteria with fibrillar tethers vibrated as a harmonic oscillator. The energy of bacteria without fibrillar tethers varied with distance in a comparable fashion as the DLVO (Derjaguin, Landau, Verwey, and Overbeek)-interaction energy. Distance variations above the surface over time of bacteria with fibrillar tethers are suggested to be governed by the harmonic oscillations, allowed by elasticity of the tethers, piercing through the potential energy barrier. Bacteria without fibrillar tethers “float” above a surface in the secondary energy minimum, with their perpendicular displacement restricted by their thermal energy and the width of the secondary minimum. The distinction between “tether-coupled” and “floating” adhesion is new, and may have implications for bacterial detachment strategies. American Chemical Society 2018-04-12 2018-05-01 /pmc/articles/PMC5942874/ /pubmed/29649869 http://dx.doi.org/10.1021/acs.langmuir.7b04331 Text en Copyright © 2018 American Chemical Society This is an open access article published under a Creative Commons Non-Commercial No Derivative Works (CC-BY-NC-ND) Attribution License (http://pubs.acs.org/page/policy/authorchoice_ccbyncnd_termsofuse.html) , which permits copying and redistribution of the article, and creation of adaptations, all for non-commercial purposes.
spellingShingle van der Westen, Rebecca
Sjollema, Jelmer
Molenaar, Robert
Sharma, Prashant K.
van der Mei, Henny C.
Busscher, Henk J.
Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
title Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
title_full Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
title_fullStr Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
title_full_unstemmed Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
title_short Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
title_sort floating and tether-coupled adhesion of bacteria to hydrophobic and hydrophilic surfaces
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5942874/
https://www.ncbi.nlm.nih.gov/pubmed/29649869
http://dx.doi.org/10.1021/acs.langmuir.7b04331
work_keys_str_mv AT vanderwestenrebecca floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces
AT sjollemajelmer floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces
AT molenaarrobert floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces
AT sharmaprashantk floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces
AT vandermeihennyc floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces
AT busscherhenkj floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces