Cargando…
Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces
[Image: see text] Models for bacterial adhesion to substratum surfaces all include uncertainty with respect to the (ir)reversibility of adhesion. In a model, based on vibrations exhibited by adhering bacteria parallel to a surface, adhesion was described as a result of reversible binding of multiple...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American
Chemical Society
2018
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5942874/ https://www.ncbi.nlm.nih.gov/pubmed/29649869 http://dx.doi.org/10.1021/acs.langmuir.7b04331 |
_version_ | 1783321535391465472 |
---|---|
author | van der Westen, Rebecca Sjollema, Jelmer Molenaar, Robert Sharma, Prashant K. van der Mei, Henny C. Busscher, Henk J. |
author_facet | van der Westen, Rebecca Sjollema, Jelmer Molenaar, Robert Sharma, Prashant K. van der Mei, Henny C. Busscher, Henk J. |
author_sort | van der Westen, Rebecca |
collection | PubMed |
description | [Image: see text] Models for bacterial adhesion to substratum surfaces all include uncertainty with respect to the (ir)reversibility of adhesion. In a model, based on vibrations exhibited by adhering bacteria parallel to a surface, adhesion was described as a result of reversible binding of multiple bacterial tethers that detach from and successively reattach to a surface, eventually making bacterial adhesion irreversible. Here, we use total internal reflection microscopy to determine whether adhering bacteria also exhibit variations over time in their perpendicular distance above surfaces. Streptococci with fibrillar surface tethers showed perpendicular vibrations with amplitudes of around 5 nm, regardless of surface hydrophobicity. Adhering, nonfibrillated streptococci vibrated with amplitudes around 20 nm above a hydrophobic surface. Amplitudes did not depend on ionic strength for either strain. Calculations of bacterial energies from their distances above the surfaces using the Boltzman equation showed that bacteria with fibrillar tethers vibrated as a harmonic oscillator. The energy of bacteria without fibrillar tethers varied with distance in a comparable fashion as the DLVO (Derjaguin, Landau, Verwey, and Overbeek)-interaction energy. Distance variations above the surface over time of bacteria with fibrillar tethers are suggested to be governed by the harmonic oscillations, allowed by elasticity of the tethers, piercing through the potential energy barrier. Bacteria without fibrillar tethers “float” above a surface in the secondary energy minimum, with their perpendicular displacement restricted by their thermal energy and the width of the secondary minimum. The distinction between “tether-coupled” and “floating” adhesion is new, and may have implications for bacterial detachment strategies. |
format | Online Article Text |
id | pubmed-5942874 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | American
Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-59428742018-05-10 Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces van der Westen, Rebecca Sjollema, Jelmer Molenaar, Robert Sharma, Prashant K. van der Mei, Henny C. Busscher, Henk J. Langmuir [Image: see text] Models for bacterial adhesion to substratum surfaces all include uncertainty with respect to the (ir)reversibility of adhesion. In a model, based on vibrations exhibited by adhering bacteria parallel to a surface, adhesion was described as a result of reversible binding of multiple bacterial tethers that detach from and successively reattach to a surface, eventually making bacterial adhesion irreversible. Here, we use total internal reflection microscopy to determine whether adhering bacteria also exhibit variations over time in their perpendicular distance above surfaces. Streptococci with fibrillar surface tethers showed perpendicular vibrations with amplitudes of around 5 nm, regardless of surface hydrophobicity. Adhering, nonfibrillated streptococci vibrated with amplitudes around 20 nm above a hydrophobic surface. Amplitudes did not depend on ionic strength for either strain. Calculations of bacterial energies from their distances above the surfaces using the Boltzman equation showed that bacteria with fibrillar tethers vibrated as a harmonic oscillator. The energy of bacteria without fibrillar tethers varied with distance in a comparable fashion as the DLVO (Derjaguin, Landau, Verwey, and Overbeek)-interaction energy. Distance variations above the surface over time of bacteria with fibrillar tethers are suggested to be governed by the harmonic oscillations, allowed by elasticity of the tethers, piercing through the potential energy barrier. Bacteria without fibrillar tethers “float” above a surface in the secondary energy minimum, with their perpendicular displacement restricted by their thermal energy and the width of the secondary minimum. The distinction between “tether-coupled” and “floating” adhesion is new, and may have implications for bacterial detachment strategies. American Chemical Society 2018-04-12 2018-05-01 /pmc/articles/PMC5942874/ /pubmed/29649869 http://dx.doi.org/10.1021/acs.langmuir.7b04331 Text en Copyright © 2018 American Chemical Society This is an open access article published under a Creative Commons Non-Commercial No Derivative Works (CC-BY-NC-ND) Attribution License (http://pubs.acs.org/page/policy/authorchoice_ccbyncnd_termsofuse.html) , which permits copying and redistribution of the article, and creation of adaptations, all for non-commercial purposes. |
spellingShingle | van der Westen, Rebecca Sjollema, Jelmer Molenaar, Robert Sharma, Prashant K. van der Mei, Henny C. Busscher, Henk J. Floating and Tether-Coupled Adhesion of Bacteria to Hydrophobic and Hydrophilic Surfaces |
title | Floating and Tether-Coupled Adhesion of Bacteria to
Hydrophobic and Hydrophilic Surfaces |
title_full | Floating and Tether-Coupled Adhesion of Bacteria to
Hydrophobic and Hydrophilic Surfaces |
title_fullStr | Floating and Tether-Coupled Adhesion of Bacteria to
Hydrophobic and Hydrophilic Surfaces |
title_full_unstemmed | Floating and Tether-Coupled Adhesion of Bacteria to
Hydrophobic and Hydrophilic Surfaces |
title_short | Floating and Tether-Coupled Adhesion of Bacteria to
Hydrophobic and Hydrophilic Surfaces |
title_sort | floating and tether-coupled adhesion of bacteria to
hydrophobic and hydrophilic surfaces |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5942874/ https://www.ncbi.nlm.nih.gov/pubmed/29649869 http://dx.doi.org/10.1021/acs.langmuir.7b04331 |
work_keys_str_mv | AT vanderwestenrebecca floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces AT sjollemajelmer floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces AT molenaarrobert floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces AT sharmaprashantk floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces AT vandermeihennyc floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces AT busscherhenkj floatingandtethercoupledadhesionofbacteriatohydrophobicandhydrophilicsurfaces |