Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit

International guidelines highlight the importance of blood pressure (BP) in patients with atrial fibrillation (AF). However, BP measurement in AF is complicated by beat-to-beat fluctuation. Automated BP measurement devices are not validated for patients with AF and no consensus exists on how to meas...

Descripción completa

Detalles Bibliográficos
Autores principales: Berkelmans, G. F. N., Kuipers, S., Westerhof, B. E., Spoelstra-de Man, A. M. E., Smulders, Y. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5943389/
https://www.ncbi.nlm.nih.gov/pubmed/28688009
http://dx.doi.org/10.1007/s10877-017-0044-9
_version_ 1783321614784397312
author Berkelmans, G. F. N.
Kuipers, S.
Westerhof, B. E.
Spoelstra-de Man, A. M. E.
Smulders, Y. M.
author_facet Berkelmans, G. F. N.
Kuipers, S.
Westerhof, B. E.
Spoelstra-de Man, A. M. E.
Smulders, Y. M.
author_sort Berkelmans, G. F. N.
collection PubMed
description International guidelines highlight the importance of blood pressure (BP) in patients with atrial fibrillation (AF). However, BP measurement in AF is complicated by beat-to-beat fluctuation. Automated BP measurement devices are not validated for patients with AF and no consensus exists on how to measure BP in AF manually. Beat-to-beat BP measurement using the volume-clamp method (VCM) could represent a non-invasive method to accurately assess BP, but has not been validated in AF. 31 admitted patients with sustained AF and 10 control patients with sinus rhythm underwent simultaneous intra-arterial and non-invasive BP measurement using a VCM monitor (Nexfin(®), BMEYE, Amsterdam, The Netherlands). Patients with compromised peripheral perfusion, high doses of vasopressor drugs or peripheral edema were excluded. Differences in systolic, diastolic and mean BP of 5 (standard deviation; SD 8) mmHg (accuracy and precision) between both methods were considered acceptable. Additionally, the magnitude of beat-to-beat fluctuations in systolic BP of both methods was compared. In AF, the differences between noninvasive and invasive BP were −4 (SD 12), +1 (SD 7) and 0 (SD 8) mmHg for systolic, diastolic and mean BP respectively. Absolute differences in beat-to-beat BP fluctuations were 1.5 (IQR 0.8–3.8) mmHg. Accuracy of VCM in AF was similar to sinus rhythm. In conclusion, in patients with AF, accurate and precise measurement of non-invasive beat-to-beat BP measurement using the VCM is possible, the one exception being the precision of systolic BP. Beat-to-beat variability can be accurately reproduced. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10877-017-0044-9) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5943389
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-59433892018-05-14 Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit Berkelmans, G. F. N. Kuipers, S. Westerhof, B. E. Spoelstra-de Man, A. M. E. Smulders, Y. M. J Clin Monit Comput Original Research International guidelines highlight the importance of blood pressure (BP) in patients with atrial fibrillation (AF). However, BP measurement in AF is complicated by beat-to-beat fluctuation. Automated BP measurement devices are not validated for patients with AF and no consensus exists on how to measure BP in AF manually. Beat-to-beat BP measurement using the volume-clamp method (VCM) could represent a non-invasive method to accurately assess BP, but has not been validated in AF. 31 admitted patients with sustained AF and 10 control patients with sinus rhythm underwent simultaneous intra-arterial and non-invasive BP measurement using a VCM monitor (Nexfin(®), BMEYE, Amsterdam, The Netherlands). Patients with compromised peripheral perfusion, high doses of vasopressor drugs or peripheral edema were excluded. Differences in systolic, diastolic and mean BP of 5 (standard deviation; SD 8) mmHg (accuracy and precision) between both methods were considered acceptable. Additionally, the magnitude of beat-to-beat fluctuations in systolic BP of both methods was compared. In AF, the differences between noninvasive and invasive BP were −4 (SD 12), +1 (SD 7) and 0 (SD 8) mmHg for systolic, diastolic and mean BP respectively. Absolute differences in beat-to-beat BP fluctuations were 1.5 (IQR 0.8–3.8) mmHg. Accuracy of VCM in AF was similar to sinus rhythm. In conclusion, in patients with AF, accurate and precise measurement of non-invasive beat-to-beat BP measurement using the VCM is possible, the one exception being the precision of systolic BP. Beat-to-beat variability can be accurately reproduced. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10877-017-0044-9) contains supplementary material, which is available to authorized users. Springer Netherlands 2017-07-07 2018 /pmc/articles/PMC5943389/ /pubmed/28688009 http://dx.doi.org/10.1007/s10877-017-0044-9 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Berkelmans, G. F. N.
Kuipers, S.
Westerhof, B. E.
Spoelstra-de Man, A. M. E.
Smulders, Y. M.
Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
title Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
title_full Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
title_fullStr Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
title_full_unstemmed Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
title_short Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
title_sort comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unit
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5943389/
https://www.ncbi.nlm.nih.gov/pubmed/28688009
http://dx.doi.org/10.1007/s10877-017-0044-9
work_keys_str_mv AT berkelmansgfn comparingvolumeclampmethodandintraarterialbloodpressuremeasurementsinpatientswithatrialfibrillationadmittedtotheintensiveormediumcareunit
AT kuiperss comparingvolumeclampmethodandintraarterialbloodpressuremeasurementsinpatientswithatrialfibrillationadmittedtotheintensiveormediumcareunit
AT westerhofbe comparingvolumeclampmethodandintraarterialbloodpressuremeasurementsinpatientswithatrialfibrillationadmittedtotheintensiveormediumcareunit
AT spoelstrademaname comparingvolumeclampmethodandintraarterialbloodpressuremeasurementsinpatientswithatrialfibrillationadmittedtotheintensiveormediumcareunit
AT smuldersym comparingvolumeclampmethodandintraarterialbloodpressuremeasurementsinpatientswithatrialfibrillationadmittedtotheintensiveormediumcareunit