Cargando…
Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols
Two ‘turn on’ TCF-based fluorescence probes were developed for the detection of biological thiols (TCF-GSH and TCFCl-GSH). TCF-GSH was shown to have a high sensitivity towards glutathione (GSH) with a 0.28 μM limit of detection. Unfortunately, at higher GSH concentrations the fluorescence intensity...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Royal Society of Chemistry
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5944426/ https://www.ncbi.nlm.nih.gov/pubmed/29683468 http://dx.doi.org/10.1039/c8cc01661e |
_version_ | 1783321822819778560 |
---|---|
author | Sedgwick, Adam C. Gardiner, Jordan E. Kim, Gyoungmi Yevglevskis, Maksims Lloyd, Matthew D. Jenkins, A. Toby A. Bull, Steven D. Yoon, Juyoung James, Tony D. |
author_facet | Sedgwick, Adam C. Gardiner, Jordan E. Kim, Gyoungmi Yevglevskis, Maksims Lloyd, Matthew D. Jenkins, A. Toby A. Bull, Steven D. Yoon, Juyoung James, Tony D. |
author_sort | Sedgwick, Adam C. |
collection | PubMed |
description | Two ‘turn on’ TCF-based fluorescence probes were developed for the detection of biological thiols (TCF-GSH and TCFCl-GSH). TCF-GSH was shown to have a high sensitivity towards glutathione (GSH) with a 0.28 μM limit of detection. Unfortunately, at higher GSH concentrations the fluorescence intensity of TCF-GSH decreased and toxicity was observed for TCF-GSH in live cells. However, TCFCl-GSH was shown to be able to detect GSH at biologically relevant concentrations with a 0.45 μM limit of detection. No toxicity was found for TCFCl-GSH and a clear ‘turn on’ with good photostability was observed for the exogenous addition of GSH, Cys and HCys. Furthermore, TCFCl-GSH was used to evaluate the effects of drug treatment on the levels of GSH in live cells. |
format | Online Article Text |
id | pubmed-5944426 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-59444262018-05-18 Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols Sedgwick, Adam C. Gardiner, Jordan E. Kim, Gyoungmi Yevglevskis, Maksims Lloyd, Matthew D. Jenkins, A. Toby A. Bull, Steven D. Yoon, Juyoung James, Tony D. Chem Commun (Camb) Chemistry Two ‘turn on’ TCF-based fluorescence probes were developed for the detection of biological thiols (TCF-GSH and TCFCl-GSH). TCF-GSH was shown to have a high sensitivity towards glutathione (GSH) with a 0.28 μM limit of detection. Unfortunately, at higher GSH concentrations the fluorescence intensity of TCF-GSH decreased and toxicity was observed for TCF-GSH in live cells. However, TCFCl-GSH was shown to be able to detect GSH at biologically relevant concentrations with a 0.45 μM limit of detection. No toxicity was found for TCFCl-GSH and a clear ‘turn on’ with good photostability was observed for the exogenous addition of GSH, Cys and HCys. Furthermore, TCFCl-GSH was used to evaluate the effects of drug treatment on the levels of GSH in live cells. Royal Society of Chemistry 2018-05-11 2018-04-17 /pmc/articles/PMC5944426/ /pubmed/29683468 http://dx.doi.org/10.1039/c8cc01661e Text en This journal is © The Royal Society of Chemistry 2018 http://creativecommons.org/licenses/by/3.0/ This article is freely available. This article is licensed under a Creative Commons Attribution 3.0 Unported Licence (CC BY 3.0) |
spellingShingle | Chemistry Sedgwick, Adam C. Gardiner, Jordan E. Kim, Gyoungmi Yevglevskis, Maksims Lloyd, Matthew D. Jenkins, A. Toby A. Bull, Steven D. Yoon, Juyoung James, Tony D. Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols |
title | Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols
|
title_full | Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols
|
title_fullStr | Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols
|
title_full_unstemmed | Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols
|
title_short | Long-wavelength TCF-based fluorescence probes for the detection and intracellular imaging of biological thiols
|
title_sort | long-wavelength tcf-based fluorescence probes for the detection and intracellular imaging of biological thiols |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5944426/ https://www.ncbi.nlm.nih.gov/pubmed/29683468 http://dx.doi.org/10.1039/c8cc01661e |
work_keys_str_mv | AT sedgwickadamc longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT gardinerjordane longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT kimgyoungmi longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT yevglevskismaksims longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT lloydmatthewd longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT jenkinsatobya longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT bullstevend longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT yoonjuyoung longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols AT jamestonyd longwavelengthtcfbasedfluorescenceprobesforthedetectionandintracellularimagingofbiologicalthiols |