Cargando…

Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study

Right ventricular pacing often results in prolonged QRS duration (QRSd) as the result of right ventricular stimulation, and atrial fibrillation (AF) may result. The association of pacing-induced prolonged QRSd and AF in patients with permanent pacemakers is unknown. We selected 180 consecutive patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Xing, FuWei, Jiang, JingZhou, Hu, XiaoLiang, Feng, Chong, He, JianGui, Dong, YuGang, Ma, YueDong, Tang, AnLi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5944699/
https://www.ncbi.nlm.nih.gov/pubmed/29419690
http://dx.doi.org/10.1097/MD.0000000000009839
_version_ 1783321877272330240
author Xing, FuWei
Jiang, JingZhou
Hu, XiaoLiang
Feng, Chong
He, JianGui
Dong, YuGang
Ma, YueDong
Tang, AnLi
author_facet Xing, FuWei
Jiang, JingZhou
Hu, XiaoLiang
Feng, Chong
He, JianGui
Dong, YuGang
Ma, YueDong
Tang, AnLi
author_sort Xing, FuWei
collection PubMed
description Right ventricular pacing often results in prolonged QRS duration (QRSd) as the result of right ventricular stimulation, and atrial fibrillation (AF) may result. The association of pacing-induced prolonged QRSd and AF in patients with permanent pacemakers is unknown. We selected 180 consecutive patients who underwent pacemaker implantation for complete/advanced atrioventricular block. All of the patients were paced from the right ventricular septum. Electrocardiography recordings were obtained at the beginning and the end of pacemaker implantation. QRSd was measured in all 12 leads. The QRSd variation was calculated by subtracting the preimplantation QRSd from the postimplantation QRSd. The occurrence of AF was observed in 64 (35.56%) patients (follow-up 33.62 ± 21.47 mo). No significant differences in preimplantation QRSd were observed between the AF occurrence and nonoccurrence groups. The QRSd variation in leads V4 (54.22 ± 29.03 vs 42.66 ± 33.79 ms, P = .022), and V6 (64.62 ± 23.16 vs 48.45 ± 34.40 ms, P = .001) differed significantly between the occurrence and nonoccurrence groups. More QRSd variation in lead V6 (P = .005, HR = 1.822, 95% CI 1.174–2.718, interval scale of QRSd was 40 ms) and left atrial diameter (P = .045, HR = 1.042, 95% CI 1.001–1.086) were independent risk factors for AF occurrence. Receiver operating characteristic curve suggested that QRSd variation in lead V6 could predict AF occurrence, especially for patients with long preimplantation QRSd (≥120 ms, area under the curve was 0.826, 95% CI 0.685–0.967). QRSd variation in lead V6 might be positively correlated with postimplantation AF occurrence. In patients with pacemaker implantation, QRSd could be a complementary criterion for optimizing the right ventricular septal pacing site, and smallest QRSd might be worth pursuing.
format Online
Article
Text
id pubmed-5944699
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-59446992018-05-17 Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study Xing, FuWei Jiang, JingZhou Hu, XiaoLiang Feng, Chong He, JianGui Dong, YuGang Ma, YueDong Tang, AnLi Medicine (Baltimore) Research Article Right ventricular pacing often results in prolonged QRS duration (QRSd) as the result of right ventricular stimulation, and atrial fibrillation (AF) may result. The association of pacing-induced prolonged QRSd and AF in patients with permanent pacemakers is unknown. We selected 180 consecutive patients who underwent pacemaker implantation for complete/advanced atrioventricular block. All of the patients were paced from the right ventricular septum. Electrocardiography recordings were obtained at the beginning and the end of pacemaker implantation. QRSd was measured in all 12 leads. The QRSd variation was calculated by subtracting the preimplantation QRSd from the postimplantation QRSd. The occurrence of AF was observed in 64 (35.56%) patients (follow-up 33.62 ± 21.47 mo). No significant differences in preimplantation QRSd were observed between the AF occurrence and nonoccurrence groups. The QRSd variation in leads V4 (54.22 ± 29.03 vs 42.66 ± 33.79 ms, P = .022), and V6 (64.62 ± 23.16 vs 48.45 ± 34.40 ms, P = .001) differed significantly between the occurrence and nonoccurrence groups. More QRSd variation in lead V6 (P = .005, HR = 1.822, 95% CI 1.174–2.718, interval scale of QRSd was 40 ms) and left atrial diameter (P = .045, HR = 1.042, 95% CI 1.001–1.086) were independent risk factors for AF occurrence. Receiver operating characteristic curve suggested that QRSd variation in lead V6 could predict AF occurrence, especially for patients with long preimplantation QRSd (≥120 ms, area under the curve was 0.826, 95% CI 0.685–0.967). QRSd variation in lead V6 might be positively correlated with postimplantation AF occurrence. In patients with pacemaker implantation, QRSd could be a complementary criterion for optimizing the right ventricular septal pacing site, and smallest QRSd might be worth pursuing. Wolters Kluwer Health 2018-02-09 /pmc/articles/PMC5944699/ /pubmed/29419690 http://dx.doi.org/10.1097/MD.0000000000009839 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle Research Article
Xing, FuWei
Jiang, JingZhou
Hu, XiaoLiang
Feng, Chong
He, JianGui
Dong, YuGang
Ma, YueDong
Tang, AnLi
Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study
title Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study
title_full Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study
title_fullStr Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study
title_full_unstemmed Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study
title_short Association between paced QRS duration and atrial fibrillation after permanent pacemaker implantation: A retrospective observational cohort study
title_sort association between paced qrs duration and atrial fibrillation after permanent pacemaker implantation: a retrospective observational cohort study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5944699/
https://www.ncbi.nlm.nih.gov/pubmed/29419690
http://dx.doi.org/10.1097/MD.0000000000009839
work_keys_str_mv AT xingfuwei associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT jiangjingzhou associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT huxiaoliang associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT fengchong associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT hejiangui associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT dongyugang associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT mayuedong associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy
AT tanganli associationbetweenpacedqrsdurationandatrialfibrillationafterpermanentpacemakerimplantationaretrospectiveobservationalcohortstudy