Cargando…

Clinical and electrophysiological evaluation of carpal tunnel syndrome: approach and pitfalls

One of the most common referrals to the electrodiagnostic (EDX) laboratory is to confirm a clinical impression of carpal tunnel syndrome (CTS). The EDX studies are valuable in localizing median nerve abnormalities to the wrist, grading its severity, and excluding other condition that can mimic or co...

Descripción completa

Detalles Bibliográficos
Autor principal: Alanazy, Mohammed H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Riyadh : Armed Forces Hospital 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5946360/
https://www.ncbi.nlm.nih.gov/pubmed/28678210
http://dx.doi.org/10.17712/nsj.2017.3.20160638
Descripción
Sumario:One of the most common referrals to the electrodiagnostic (EDX) laboratory is to confirm a clinical impression of carpal tunnel syndrome (CTS). The EDX studies are valuable in localizing median nerve abnormalities to the wrist, grading its severity, and excluding other condition that can mimic or coexist with CTS. However, there are many clinical and EDX pitfalls that can lead to misdiagnosis. Careful clinical assessment and attention to technical factors and details of the EDX techniques are fundamental for the quality and accurate interpretation of the study. This review aims to discuss the clinical and the EDX approaches to the diagnosis of CTS with emphasis on the commonly encountered pitfalls.