Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo

PURPOSE: To perform in vivo isotropic‐resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase‐navigated diffusion‐prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase‐error correction and to investigate the impr...

Descripción completa

Detalles Bibliográficos
Autores principales: Cervantes, Barbara, Van, Anh T., Weidlich, Dominik, Kooijman, Hendrick, Hock, Andreas, Rummeny, Ernst J., Gersing, Alexandra, Kirschke, Jan S., Karampinos, Dimitrios C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5947302/
https://www.ncbi.nlm.nih.gov/pubmed/29380414
http://dx.doi.org/10.1002/mrm.27072
_version_ 1783322344777842688
author Cervantes, Barbara
Van, Anh T.
Weidlich, Dominik
Kooijman, Hendrick
Hock, Andreas
Rummeny, Ernst J.
Gersing, Alexandra
Kirschke, Jan S.
Karampinos, Dimitrios C.
author_facet Cervantes, Barbara
Van, Anh T.
Weidlich, Dominik
Kooijman, Hendrick
Hock, Andreas
Rummeny, Ernst J.
Gersing, Alexandra
Kirschke, Jan S.
Karampinos, Dimitrios C.
author_sort Cervantes, Barbara
collection PubMed
description PURPOSE: To perform in vivo isotropic‐resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase‐navigated diffusion‐prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase‐error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. METHODS: Phase‐navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy‐current effects on the signal magnitude. Phase navigation of motion‐induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single‐shot echo planar imaging (ss‐EPI) in 13 subjects. Diffusion data were phase‐corrected per k (z) plane with respect to T(2)‐weighted data. The effects of motion‐induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss‐EPI. RESULTS: Non–phase‐corrected 3D TSE resulted in artifacts in diffusion‐weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD] = 2.06 ± 0.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD = 1.73 ± 0.26) of statistical significance (P ≤ 0.001) and in closer agreement with ss‐EPI DTI parameters (MD = 1.62 ± 0.21). CONCLUSION: DP 3D TSE with phase correction allows distortion‐free isotropic diffusion imaging of lower back nerves with robustness to motion‐induced artifacts and DTI quantification errors. Magn Reson Med 80:609–618, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
format Online
Article
Text
id pubmed-5947302
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59473022018-05-17 Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo Cervantes, Barbara Van, Anh T. Weidlich, Dominik Kooijman, Hendrick Hock, Andreas Rummeny, Ernst J. Gersing, Alexandra Kirschke, Jan S. Karampinos, Dimitrios C. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: To perform in vivo isotropic‐resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase‐navigated diffusion‐prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase‐error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. METHODS: Phase‐navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy‐current effects on the signal magnitude. Phase navigation of motion‐induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single‐shot echo planar imaging (ss‐EPI) in 13 subjects. Diffusion data were phase‐corrected per k (z) plane with respect to T(2)‐weighted data. The effects of motion‐induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss‐EPI. RESULTS: Non–phase‐corrected 3D TSE resulted in artifacts in diffusion‐weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD] = 2.06 ± 0.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD = 1.73 ± 0.26) of statistical significance (P ≤ 0.001) and in closer agreement with ss‐EPI DTI parameters (MD = 1.62 ± 0.21). CONCLUSION: DP 3D TSE with phase correction allows distortion‐free isotropic diffusion imaging of lower back nerves with robustness to motion‐induced artifacts and DTI quantification errors. Magn Reson Med 80:609–618, 2018. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. John Wiley and Sons Inc. 2018-01-29 2018-08 /pmc/articles/PMC5947302/ /pubmed/29380414 http://dx.doi.org/10.1002/mrm.27072 Text en © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Full Papers—Imaging Methodology
Cervantes, Barbara
Van, Anh T.
Weidlich, Dominik
Kooijman, Hendrick
Hock, Andreas
Rummeny, Ernst J.
Gersing, Alexandra
Kirschke, Jan S.
Karampinos, Dimitrios C.
Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo
title Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo
title_full Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo
title_fullStr Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo
title_full_unstemmed Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo
title_short Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3D turbo spin echo
title_sort isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase‐corrected diffusion‐prepared 3d turbo spin echo
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5947302/
https://www.ncbi.nlm.nih.gov/pubmed/29380414
http://dx.doi.org/10.1002/mrm.27072
work_keys_str_mv AT cervantesbarbara isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT vananht isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT weidlichdominik isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT kooijmanhendrick isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT hockandreas isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT rummenyernstj isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT gersingalexandra isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT kirschkejans isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho
AT karampinosdimitriosc isotropicresolutiondiffusiontensorimagingoflumbosacralandsciaticnervesusingaphasecorrecteddiffusionprepared3dturbospinecho