Cargando…

Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor

We present a microfabricated spiral-coupled passive resonator sensor realized through integrated passive device (IPD) technology for the sensitive detection and characterization of water-ethanol solutions. In order to validate the performance of the proposed device, we explicitly measured and analyz...

Descripción completa

Detalles Bibliográficos
Autores principales: Koirala, Gyan Raj, Dhakal, Rajendra, Kim, Eun-Seong, Yao, Zhao, Kim, Nam-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948501/
https://www.ncbi.nlm.nih.gov/pubmed/29614033
http://dx.doi.org/10.3390/s18041075
_version_ 1783322563756163072
author Koirala, Gyan Raj
Dhakal, Rajendra
Kim, Eun-Seong
Yao, Zhao
Kim, Nam-Young
author_facet Koirala, Gyan Raj
Dhakal, Rajendra
Kim, Eun-Seong
Yao, Zhao
Kim, Nam-Young
author_sort Koirala, Gyan Raj
collection PubMed
description We present a microfabricated spiral-coupled passive resonator sensor realized through integrated passive device (IPD) technology for the sensitive detection and characterization of water-ethanol solutions. In order to validate the performance of the proposed device, we explicitly measured and analyzed the radio frequency (RF) characteristics of various water-ethanol solution compositions. The measured results showed a drift in the resonance frequency from 1.16 GHz for deionized (DI) water to 1.68 GHz for the solution containing 50% ethanol, whereas the rejection level given by the reflection coefficient decreased from −29.74 dB to −14.81 dB. The obtained limit of detection was 3.82% volume composition of ethanol in solution. The derived loaded capacitance was 21.76 pF for DI water, which gradually decreased to 8.70 pF for the 50% ethanol solution, and the corresponding relative permittivity of the solution decreased from 80.14 to 47.79. The dissipation factor increased with the concentration of ethanol in the solution. We demonstrated the reproducibility of the proposed sensor through iterative measures of the samples and the study of surface morphology. Successive measurement of different samples had no overlapping and had very minimum bias between RF characteristics for each measured sample. The surface profile for bare sensors was retained after the sample test, resulting a root mean square (RMS) value of 11.416 nm as compared to 10.902 nm for the bare test. The proposed sensor was shown to be a viable alternative to existing sensors for highly sensitive water-ethanol concentration detection.
format Online
Article
Text
id pubmed-5948501
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-59485012018-05-17 Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor Koirala, Gyan Raj Dhakal, Rajendra Kim, Eun-Seong Yao, Zhao Kim, Nam-Young Sensors (Basel) Article We present a microfabricated spiral-coupled passive resonator sensor realized through integrated passive device (IPD) technology for the sensitive detection and characterization of water-ethanol solutions. In order to validate the performance of the proposed device, we explicitly measured and analyzed the radio frequency (RF) characteristics of various water-ethanol solution compositions. The measured results showed a drift in the resonance frequency from 1.16 GHz for deionized (DI) water to 1.68 GHz for the solution containing 50% ethanol, whereas the rejection level given by the reflection coefficient decreased from −29.74 dB to −14.81 dB. The obtained limit of detection was 3.82% volume composition of ethanol in solution. The derived loaded capacitance was 21.76 pF for DI water, which gradually decreased to 8.70 pF for the 50% ethanol solution, and the corresponding relative permittivity of the solution decreased from 80.14 to 47.79. The dissipation factor increased with the concentration of ethanol in the solution. We demonstrated the reproducibility of the proposed sensor through iterative measures of the samples and the study of surface morphology. Successive measurement of different samples had no overlapping and had very minimum bias between RF characteristics for each measured sample. The surface profile for bare sensors was retained after the sample test, resulting a root mean square (RMS) value of 11.416 nm as compared to 10.902 nm for the bare test. The proposed sensor was shown to be a viable alternative to existing sensors for highly sensitive water-ethanol concentration detection. MDPI 2018-04-03 /pmc/articles/PMC5948501/ /pubmed/29614033 http://dx.doi.org/10.3390/s18041075 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Koirala, Gyan Raj
Dhakal, Rajendra
Kim, Eun-Seong
Yao, Zhao
Kim, Nam-Young
Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor
title Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor
title_full Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor
title_fullStr Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor
title_full_unstemmed Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor
title_short Radio Frequency Detection and Characterization of Water-Ethanol Solution through Spiral-Coupled Passive Micro-Resonator Sensor
title_sort radio frequency detection and characterization of water-ethanol solution through spiral-coupled passive micro-resonator sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948501/
https://www.ncbi.nlm.nih.gov/pubmed/29614033
http://dx.doi.org/10.3390/s18041075
work_keys_str_mv AT koiralagyanraj radiofrequencydetectionandcharacterizationofwaterethanolsolutionthroughspiralcoupledpassivemicroresonatorsensor
AT dhakalrajendra radiofrequencydetectionandcharacterizationofwaterethanolsolutionthroughspiralcoupledpassivemicroresonatorsensor
AT kimeunseong radiofrequencydetectionandcharacterizationofwaterethanolsolutionthroughspiralcoupledpassivemicroresonatorsensor
AT yaozhao radiofrequencydetectionandcharacterizationofwaterethanolsolutionthroughspiralcoupledpassivemicroresonatorsensor
AT kimnamyoung radiofrequencydetectionandcharacterizationofwaterethanolsolutionthroughspiralcoupledpassivemicroresonatorsensor