Cargando…
Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia
OBJECTIVE: Sputum smear microscopy reading errors are likely to result in failure to detect persons with infectious TB. This study was intended to review misdiagnosis of pulmonary TB and associated factors in peripheral laboratories. RESULTS: During the study period 1033 (10.5%) sputum smear positiv...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948669/ https://www.ncbi.nlm.nih.gov/pubmed/29751778 http://dx.doi.org/10.1186/s13104-018-3414-6 |
_version_ | 1783322602489511936 |
---|---|
author | Desalegn, Daniel Melese Kitila, Kumera Terfa Balcha, Hanna Mekonnen Gebeyehu, Chalachew Sisay Kidan, Yohannes W. Amare, Kassayenew Dejene, Daniel Seifu, Merone Zewdie, Addis Tenna, Abiyot Hailu, Tinsae Kidanemariam Taddese, Boja Dufera Bika, Abrham Tesfaye |
author_facet | Desalegn, Daniel Melese Kitila, Kumera Terfa Balcha, Hanna Mekonnen Gebeyehu, Chalachew Sisay Kidan, Yohannes W. Amare, Kassayenew Dejene, Daniel Seifu, Merone Zewdie, Addis Tenna, Abiyot Hailu, Tinsae Kidanemariam Taddese, Boja Dufera Bika, Abrham Tesfaye |
author_sort | Desalegn, Daniel Melese |
collection | PubMed |
description | OBJECTIVE: Sputum smear microscopy reading errors are likely to result in failure to detect persons with infectious TB. This study was intended to review misdiagnosis of pulmonary TB and associated factors in peripheral laboratories. RESULTS: During the study period 1033 (10.5%) sputum smear positive and 8783 (89.5%) smear negative slides were reported by peripheral laboratories. The slides were re-read by the central referral laboratories (CRLs) as the reference standard reading. Of 1033 positive slides reported by peripheral laboratories, 25 (2.4%) were false positive. Out of 8783 smear negative slides reported by peripheral laboratories, 35 (0.4%) were false negative. The sensitivity, specificity, positive predictive value and negative predictive value of peripheral laboratories were 96.64, 99.72, 97.58, and 99.61% respectively. The peripheral laboratories and CRLs have an observed agreement (Po) of 0.9939. Of 135 peripheral laboratories, 93 (68.9%) read negative and positive slides correctly, 49 (36.3%) did not have lens cleaning tissue papers, 11 (8.1%) lacked frosted slides, and 14 (10.4%) had shortage of reagents. As conclusions, the peripheral laboratories and CRLs had high agreement for sputum smear microscopy reading. However, a few TB cases were misdiagnosed despite having the disease; these individuals might continue to spread the infection in the community. |
format | Online Article Text |
id | pubmed-5948669 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-59486692018-05-17 Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia Desalegn, Daniel Melese Kitila, Kumera Terfa Balcha, Hanna Mekonnen Gebeyehu, Chalachew Sisay Kidan, Yohannes W. Amare, Kassayenew Dejene, Daniel Seifu, Merone Zewdie, Addis Tenna, Abiyot Hailu, Tinsae Kidanemariam Taddese, Boja Dufera Bika, Abrham Tesfaye BMC Res Notes Research Note OBJECTIVE: Sputum smear microscopy reading errors are likely to result in failure to detect persons with infectious TB. This study was intended to review misdiagnosis of pulmonary TB and associated factors in peripheral laboratories. RESULTS: During the study period 1033 (10.5%) sputum smear positive and 8783 (89.5%) smear negative slides were reported by peripheral laboratories. The slides were re-read by the central referral laboratories (CRLs) as the reference standard reading. Of 1033 positive slides reported by peripheral laboratories, 25 (2.4%) were false positive. Out of 8783 smear negative slides reported by peripheral laboratories, 35 (0.4%) were false negative. The sensitivity, specificity, positive predictive value and negative predictive value of peripheral laboratories were 96.64, 99.72, 97.58, and 99.61% respectively. The peripheral laboratories and CRLs have an observed agreement (Po) of 0.9939. Of 135 peripheral laboratories, 93 (68.9%) read negative and positive slides correctly, 49 (36.3%) did not have lens cleaning tissue papers, 11 (8.1%) lacked frosted slides, and 14 (10.4%) had shortage of reagents. As conclusions, the peripheral laboratories and CRLs had high agreement for sputum smear microscopy reading. However, a few TB cases were misdiagnosed despite having the disease; these individuals might continue to spread the infection in the community. BioMed Central 2018-05-11 /pmc/articles/PMC5948669/ /pubmed/29751778 http://dx.doi.org/10.1186/s13104-018-3414-6 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Note Desalegn, Daniel Melese Kitila, Kumera Terfa Balcha, Hanna Mekonnen Gebeyehu, Chalachew Sisay Kidan, Yohannes W. Amare, Kassayenew Dejene, Daniel Seifu, Merone Zewdie, Addis Tenna, Abiyot Hailu, Tinsae Kidanemariam Taddese, Boja Dufera Bika, Abrham Tesfaye Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia |
title | Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia |
title_full | Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia |
title_fullStr | Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia |
title_full_unstemmed | Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia |
title_short | Misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, Addis Ababa, Ethiopia |
title_sort | misdiagnosis of pulmonary tuberculosis and associated factors in peripheral laboratories: a retrospective study, addis ababa, ethiopia |
topic | Research Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948669/ https://www.ncbi.nlm.nih.gov/pubmed/29751778 http://dx.doi.org/10.1186/s13104-018-3414-6 |
work_keys_str_mv | AT desalegndanielmelese misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT kitilakumeraterfa misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT balchahannamekonnen misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT gebeyehuchalachewsisay misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT kidanyohannesw misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT amarekassayenew misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT dejenedaniel misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT seifumerone misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT zewdieaddis misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT tennaabiyot misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT hailutinsaekidanemariam misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT taddesebojadufera misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia AT bikaabrhamtesfaye misdiagnosisofpulmonarytuberculosisandassociatedfactorsinperipherallaboratoriesaretrospectivestudyaddisababaethiopia |