Cargando…

On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid

Counting blood cells in cerebrospinal fluid (CSF) is indispensable for diagnosing several pathological conditions in the central nervous system, such as meningitis, even though collecting CSF samples is invasive. Cell counting methods, such as hemocytometer chambers and flow cytometers, have been us...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yujin, Kim, Byeongyeon, Choi, Sungyoung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948756/
https://www.ncbi.nlm.nih.gov/pubmed/29642424
http://dx.doi.org/10.3390/s18041124
_version_ 1783322622833983488
author Lee, Yujin
Kim, Byeongyeon
Choi, Sungyoung
author_facet Lee, Yujin
Kim, Byeongyeon
Choi, Sungyoung
author_sort Lee, Yujin
collection PubMed
description Counting blood cells in cerebrospinal fluid (CSF) is indispensable for diagnosing several pathological conditions in the central nervous system, such as meningitis, even though collecting CSF samples is invasive. Cell counting methods, such as hemocytometer chambers and flow cytometers, have been used for CSF cell counting, but they often lack the sensitivity to detect low blood cell numbers. They also depend on off-chip, manual sample preparation or require bulky, costly equipment, thereby limiting their clinical utility. Here, we present a portable cell counting platform for simple, rapid CSF cell counting that integrates a microfluidic cell counting chamber with a miniaturized microscope. The microfluidic chamber is designed not only to be a reagent container for on-chip cell staining but also to have a large control volume for accurate cell counting. The proposed microscope miniaturizes both bright-field and fluorescence microscopy with a simple optical setup and a custom cell-counting program, thereby allowing rapid and automated cell counting of nucleated white blood cells and non-nucleated red blood cells in fluorescence and bright-field images. Using these unique features, we successfully demonstrate the ability of our counting platform to measure low CSF cell counts without sample preparation.
format Online
Article
Text
id pubmed-5948756
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-59487562018-05-17 On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid Lee, Yujin Kim, Byeongyeon Choi, Sungyoung Sensors (Basel) Article Counting blood cells in cerebrospinal fluid (CSF) is indispensable for diagnosing several pathological conditions in the central nervous system, such as meningitis, even though collecting CSF samples is invasive. Cell counting methods, such as hemocytometer chambers and flow cytometers, have been used for CSF cell counting, but they often lack the sensitivity to detect low blood cell numbers. They also depend on off-chip, manual sample preparation or require bulky, costly equipment, thereby limiting their clinical utility. Here, we present a portable cell counting platform for simple, rapid CSF cell counting that integrates a microfluidic cell counting chamber with a miniaturized microscope. The microfluidic chamber is designed not only to be a reagent container for on-chip cell staining but also to have a large control volume for accurate cell counting. The proposed microscope miniaturizes both bright-field and fluorescence microscopy with a simple optical setup and a custom cell-counting program, thereby allowing rapid and automated cell counting of nucleated white blood cells and non-nucleated red blood cells in fluorescence and bright-field images. Using these unique features, we successfully demonstrate the ability of our counting platform to measure low CSF cell counts without sample preparation. MDPI 2018-04-07 /pmc/articles/PMC5948756/ /pubmed/29642424 http://dx.doi.org/10.3390/s18041124 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Yujin
Kim, Byeongyeon
Choi, Sungyoung
On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
title On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
title_full On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
title_fullStr On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
title_full_unstemmed On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
title_short On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
title_sort on-chip cell staining and counting platform for the rapid detection of blood cells in cerebrospinal fluid
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948756/
https://www.ncbi.nlm.nih.gov/pubmed/29642424
http://dx.doi.org/10.3390/s18041124
work_keys_str_mv AT leeyujin onchipcellstainingandcountingplatformfortherapiddetectionofbloodcellsincerebrospinalfluid
AT kimbyeongyeon onchipcellstainingandcountingplatformfortherapiddetectionofbloodcellsincerebrospinalfluid
AT choisungyoung onchipcellstainingandcountingplatformfortherapiddetectionofbloodcellsincerebrospinalfluid