Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers

The aim of this study is on the investigation of motion noise removal techniques using two-accelerometer sensor system and various placements of the sensors on gentle movement and walking of the patients. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Luu, Loc, Dinh, Anh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948894/
https://www.ncbi.nlm.nih.gov/pubmed/29614821
http://dx.doi.org/10.3390/s18041067
_version_ 1783322655178358784
author Luu, Loc
Dinh, Anh
author_facet Luu, Loc
Dinh, Anh
author_sort Luu, Loc
collection PubMed
description The aim of this study is on the investigation of motion noise removal techniques using two-accelerometer sensor system and various placements of the sensors on gentle movement and walking of the patients. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and process data while the subjects are in motion. The tests include eight volunteers who have no record of heart disease. The walking and running data on the subjects are analyzed to find the minimal-noise bandwidth of the SCG signal. This bandwidth is used to design filters in the motion noise removal techniques and peak signal detection. There are two main techniques of combining signals from the two sensors to mitigate the motion artifact: analog processing and digital processing. The analog processing comprises analog circuits performing adding or subtracting functions and bandpass filter to remove artifact noises before entering the data acquisition system. The digital processing processes all the data using combinations of total acceleration and z-axis only acceleration. The two techniques are tested on three placements of accelerometer sensors including horizontal, vertical, and diagonal on gentle motion and walking. In general, the total acceleration and z-axis acceleration are the best techniques to deal with gentle motion on all sensor placements which improve average systolic signal-noise-ratio (SNR) around 2 times and average diastolic SNR around 3 times comparing to traditional methods using only one accelerometer. With walking motion, ADDER and z-axis acceleration are the best techniques on all placements of the sensors on the body which enhance about 7 times of average systolic SNR and about 11 times of average diastolic SNR comparing to only one accelerometer method. Among the sensor placements, the performance of horizontal placement of the sensors is outstanding comparing with other positions on all motions.
format Online
Article
Text
id pubmed-5948894
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-59488942018-05-17 Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers Luu, Loc Dinh, Anh Sensors (Basel) Article The aim of this study is on the investigation of motion noise removal techniques using two-accelerometer sensor system and various placements of the sensors on gentle movement and walking of the patients. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and process data while the subjects are in motion. The tests include eight volunteers who have no record of heart disease. The walking and running data on the subjects are analyzed to find the minimal-noise bandwidth of the SCG signal. This bandwidth is used to design filters in the motion noise removal techniques and peak signal detection. There are two main techniques of combining signals from the two sensors to mitigate the motion artifact: analog processing and digital processing. The analog processing comprises analog circuits performing adding or subtracting functions and bandpass filter to remove artifact noises before entering the data acquisition system. The digital processing processes all the data using combinations of total acceleration and z-axis only acceleration. The two techniques are tested on three placements of accelerometer sensors including horizontal, vertical, and diagonal on gentle motion and walking. In general, the total acceleration and z-axis acceleration are the best techniques to deal with gentle motion on all sensor placements which improve average systolic signal-noise-ratio (SNR) around 2 times and average diastolic SNR around 3 times comparing to traditional methods using only one accelerometer. With walking motion, ADDER and z-axis acceleration are the best techniques on all placements of the sensors on the body which enhance about 7 times of average systolic SNR and about 11 times of average diastolic SNR comparing to only one accelerometer method. Among the sensor placements, the performance of horizontal placement of the sensors is outstanding comparing with other positions on all motions. MDPI 2018-04-02 /pmc/articles/PMC5948894/ /pubmed/29614821 http://dx.doi.org/10.3390/s18041067 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Luu, Loc
Dinh, Anh
Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
title Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
title_full Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
title_fullStr Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
title_full_unstemmed Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
title_short Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
title_sort artifact noise removal techniques on seismocardiogram using two tri-axial accelerometers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5948894/
https://www.ncbi.nlm.nih.gov/pubmed/29614821
http://dx.doi.org/10.3390/s18041067
work_keys_str_mv AT luuloc artifactnoiseremovaltechniquesonseismocardiogramusingtwotriaxialaccelerometers
AT dinhanh artifactnoiseremovaltechniquesonseismocardiogramusingtwotriaxialaccelerometers